1 February 2002 in Applied Optics
A Fourier-transform imaging spectrometer, believed to be novel, based on the Savart polariscope is presented. There is no slit in this instrument, which means that it has a high throughput. The principle and the system configuration are described. Several preliminary experimental results are shown.
1 September 2009 in Optical Review
24 March 2010 in Applied Optics
We propose a novel, high-contrast imager called a polarization interferometric nulling coronagraph (PINC) for direct detection of extrasolar planets. The PINC uses achromatic half-wave plates (HWPs) installed in a fully symmetric beam combiner based on polarizing beam splitters. Jones calculus suggests that a stellar halo suppression level of can be achieved at 5 for a broad wavelength range from 1.6 to by using Fresnel-rhomb HWPs made of BK7. Laboratory experiments on the PINC used two laser light sources (wavelengths of and ), and we obtained a halo suppression level of approximately at 5 for both wavelengths.
14 February 2022 in The Astronomical Journal
Direct detection of exoplanets requires a high-contrast instrument called a coronagraph to reject bright light from the central star. However, a coronagraph cannot perfectly reject the starlight if the incoming stellar wave front is distorted by aberrations due to the Earth’s atmospheric turbulence and/or the telescope instrumental optics. Wave-front aberrations cause residual stellar speckles that prevent detection of faint planetary light. In this paper, we report a laboratory demonstration of a speckle-nulling wave-front control using a spatial light modulator (SLM) to suppress the residual speckles of a common-path visible nulling coronagraph. Because of its large format, the SLM potentially has the ability to generate a dark hole over a large region or at a large angular distance from a star of up to hundreds of λ/D. We carry out a laboratory demonstration for three cases of dark hole generation: (1) in an inner region (3–8 λ/D in horizontal and 5–15 λ/D in vertical directions), (2) in an outer region (70–75 λ/D in horizontal and 65–75 λ/D in vertical directions), and (3) in a large region (5–75 λ/D in both directions). As a result, the residual speckles are rejected to contrast levels on the order of 10−8 in cases 1 and 2. In cases 2 and 3, we can generate dark holes at a large distance (up to >100 λ/D) and with a large size (70 λ/D square), both of which are out of the Nyquist limit of currently available deformable mirrors.