Liang Gong

Liang Gong

Auto-generated profile, based on publicly available information

Liang Gong

School of Civil Engineering, Southeast University, Nanjing 211189, Jiangsu, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
LGLiang Gong
Liang Gong
ZCZhongfan Chen
Zhongfan Chen
YFYan Feng
Yan Feng
SRSihan Ruan
Sihan Ruan
LTLiuhui Tu
Liuhui Tu
This paper presents an innovative hollow concrete floor system comprising hollow precast panels and self‐thermal‐insulation infills. The precast panels are connected by welded reinforcement bars and cast‐in‐situ concrete joints. To study the vertical load‐carrying capacity and the working mechanism of this innovative floor system, a static loading test was carried out on a 1/2 scale model. The specimen consists of six precast slab members, four precast reinforced concrete beams and columns, respectively. Experimental and simulation results related to the crack development and vertical load‐carrying capacity were analyzed. It is found that the innovative floor system could meet the capacity requirements of the Chinese code. Furthermore, the crack development of the innovative system shows similar characteristics with the solid floor. To explore the feasibility of the existed analysis methods, the specimen was simulated and compared by nonlinear analysis in ABAQUS. The comparison illustrates that the analogue cross beam method is more accurate and suitable for the simulation of the innovative hollow concrete floor system.

1 January 2022 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
JSJinbo Sun
Jinbo Sun
KSKe Sun
Ke Sun
LGLiang Gong
Liang Gong
SGSheng Gu
Sheng Gu
HHHao Hao
Hao Hao
Many monitoring indexes affect the health condition of foundation pits to different extents. How to use a massive on‐site monitoring dataset to quantitatively assess the health of foundation pits is a problem that deserves due consideration. This paper proposes a foundation pit health assessment model based on the fuzzy analytical hierarchy process (AHP) method. First, factors affecting the health of foundation pits are classified by the AHP, a hierarchical factor system for foundation pit health assessment is established, and the index scale method is used to assign weights to assessment factors at different hierarchical levels. Combined with the fuzzy mathematical method, the membership functions of four health degree levels (A to D) are constructed, and the determination range of each health degree level is given to realize the quantitative calculation of the health condition from the bottom‐level assessment factor to the overall foundation pit. Considering that each assessment factor involves many monitoring points and different monitoring data, a comprehensive assessment operator is also constructed to highlight the most adverse impact. Finally, the proposed model is used to perform a health assessment of an actual foundation pit project, and the variation in the foundation pit health during the entire monitoring period is obtained. The health grade of the foundation pit is determined to be B, which is a basically healthy condition consistent with the on‐site inspection results.