Petr Bitala

Petr Bitala

Auto-generated profile, based on publicly available information

Petr Bitala

Faculty of Safety Engineering, VSB-Technical University of Ostrava, Lumírova 630/13, 700 30 Ostrava-Výškovice, Czech Republic

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Microchemical Journal
Verified
Journal Article
Closed access
JSJan Suchánek
Jan Suchánek
PJPavel Janda
Pavel Janda
MDMichal Dostál
Michal Dostál
AKAntonín Knížek
Antonín Knížek
PKPavel Kubát
Pavel Kubát
ZZZdeněk Zelinger
Zdeněk Zelinger

1 April 2017 in Measurement
Verified
Journal Article
Closed access
JSJan Suchánek
Jan Suchánek
MDMichal Dostál
Michal Dostál
TVTereza Vlasáková
Tereza Vlasáková
PJPavel Janda
Pavel Janda
MKMonika Klusáčková
Monika Klusáčková
ZZZdeněk Zelinger
Zdeněk Zelinger

1 January 2012 in Procedia Engineering
Verified
Journal Article
Open access
MKM. Kozubková
M. Kozubková
EKE. Kozubek
E. Kozubek
VNV. Nevrlý
V. Nevrlý
PBP. Bitala
P. Bitala
OŠO. Štěpánek
O. Štěpánek
EGE. Grigorová
E. Grigorová
Numerical simulation of dilution effect on combustion and flame properties is desirable for various industrial or scientific applications. Predicative capabilities of the simplified (one- and two-step) chemical kinetic mechanisms of methane oxidation in highly diluted flames were evaluated on the basis of mathematical modelling in one-dimensional (axisymmetric) configuration. Profiles of temperatures and concentrations of reactants, combustion products and intermediates in premixed flat flame and nonpremixed counterflow flame burning methane and air/diluent mixture were determined. Detailed chemical kinetic modelling was performed additionally in order estimate the flame temperature and speciation and to quantify the effect of elevated argon and nitrogen concentration and oxygen deficiency on diluted combustion. Global chemical kinetic models were implemented into computational fluid dynamics tool to approve their applicability for numerical simulations of diluted flames in more complex geometries

25 September 2012 in Contributions to Plasma Physics
Verified
Journal Article
Closed access
PDF file
JWJ. Wild
J. Wild
PKPavel Kudrna
Pavel Kudrna
Milan TichyMilan Tichy
Milan Tichy
VNV. Nevrlý
V. Nevrlý
MSM. Střižík
M. Střižík
ZZZ. Zelinger
Z. Zelinger

5 June 2018 in Energy & Fuels
Verified
Journal Article
Closed access
MDMichal Dostál
Michal Dostál
JSJan Suchánek
Jan Suchánek
VVVáclav Válek
Václav Válek
ZBZuzana Blatoňová
Zuzana Blatoňová
VNVáclav Nevrlý
Václav Nevrlý
ZZZdeněk Zelinger
Zdeněk Zelinger

5 March 2015 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
ZZZ. Zelinger
Z. Zelinger
PJPavel Janda
Pavel Janda
JSJ. Suchánek
J. Suchánek
MDMichal Dostál
Michal Dostál
PKPavel Kubat
Pavel Kubat
SCS. Civiš
S. Civiš
Laser photoacoustic spectroscopy (PAS) is a method that utilizes the sensing of the pressure waves that emerge upon the absorption of radiation by absorbing species. The use of the conventional electret microphone as a pressure sensor has already reached its limit, and a new type of microphone – an optical microphone – has been suggested to increase the sensitivity of this method. The movement of a micro-lever or a membrane is sensed via a reflected beam of light, which falls onto a position-sensing detector. The use of one micro-lever as a pressure sensor in the form of a silicon cantilever has already enhanced the sensitivity of laser PAS. Herein, we test two types of home-made sensing elements – four coupled silicon micro-levers and a multilayer graphene membrane – which have the potential to enhance this sensitivity further. Graphene sheets possess outstanding electromechanical properties and demonstrate impressive sensitivity as mass detectors. Their mechanical properties make them suitable for use as micro-/nano-levers or membranes, which could function as extremely sensitive pressure sensors. Graphene sheets were prepared from multilayer graphene through the micromechanical cleavage of basal plane highly ordered pyrolytic graphite. Multilayer graphene sheets (thickness ∼102 nm) were then mounted on an additional glass window in a cuvette for PAS. The movements of the sheets induced by acoustic waves were measured using an He–Ne laser beam reflected from the sheets onto a quadrant detector. A discretely tunable CO2 laser was used as the source of radiation energy for the laser PAS experiments. Sensitivity testing of the investigated sensing elements was performed with the aid of concentration standards and a mixing arrangement in a flow regime. The combination of sensitive microphones and micromechanical/nanomechanical elements with laser techniques offers a method for the study and development of new, reliable and highly sensitive chemical sensing systems. To our knowledge, we have produced the first demonstration of the feasibility of using four coupled silicon micro-levers and graphene membranes in an optical microphone for PAS. Although the sensitivity thus far remains inferior to that of the commercial electret microphone (with an S / N ratio that is 5 times lower), further improvement is expected to be achieved by adjusting the micro-levers and membrane elements, the photoacoustic system and the position detector.