Donika Plyku

Donika Plyku

Auto-generated profile, based on publicly available information

Donika Plyku

Johns Hopkins University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2018 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
CFCatherine A. Foss
Catherine A. Foss
DPDonika Plyku
Donika Plyku
AOAlvaro Ordonez
Alvaro Ordonez
JSJulian Sanchez-Bautista
Julian Sanchez-Bautista
HRHailey B. Rosenthal
Hailey B. Rosenthal
SJSanjay Jain
Sanjay Jain
Whole body PET/CT imaging was performed using 124I-iodo-DPA-713, a radioligand for the 18-kDa translocator protein (TSPO), to determine biodistribution and radiation dosimetry. Methods. Healthy subjects ages 18-65 years underwent whole body PET/CT imaging at either 4, 24 and 48 hours or 24, 48 and 72 hours after intravenous injection with 124I-iodo-DPA-713. Time-activity curves were generated and used to calculate organ time-integrated activity coefficients for each subject. The resulting time-integrated activity coefficients provided input data for calculation of organ absorbed doses and effective dose for each subject using OLINDA. Subjects were genotyped for the TSPO polymorphism, rs6971, and plasma protein binding of 124I-iodo-DPA-713 was measured. Results. Three male and three female adults with mean age of 40 ± 19 years were imaged. The mean administered activity and mass were 70.5 ± 5.1 (range, 62.4-78.1) MBq and 469 ± 34 (range, 416-520) ng respectively. There were no adverse or clinically detectable pharmacologic effects in any of the six subjects. No changes in vital signs, laboratory values or electrocardiograms were observed. 124I-Iodo-DPA-713 cleared rapidly (4 hours post-injection) from the lungs with hepatic elimination and localization to the gastrointestinal tract. The mean effective dose over six subjects was 0.459 ± 0.127 mSv/MBq with the liver being the dose-limiting organ (0.924 ± 0.501 mGy/MBq). The percentage of free radiotracer in blood was ~30% at 30 and 60 minutes post-injection. Conclusion. Iodo-DPA-713 is cleared rapidly from the lungs with predominant hepatic elimination. It is safe and well-tolerated in healthy adult subjects.

4 February 2022 in Annals of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
DPDonika Plyku
Donika Plyku
RHRobert F. Hobbs
Robert F. Hobbs
DWDi Wu
Di Wu
CGCarlos Garcia
Carlos Garcia
GSGeorge Sgouros
George Sgouros
DNDouglas Van Nostrand
Douglas Van Nostrand

25 November 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JBJustin L Brown
Justin L Brown
BSBriana Sexton-Stallone
Briana Sexton-Stallone
YLYe Li
Ye Li
EFEric C Frey
Eric C Frey
STS Ted Treves
S Ted Treves
WBWesley E Bolch
Wesley E Bolch
Current guidelines for administered activity (AA) in pediatric nuclear medicine imaging studies are based on a 2016 harmonization of the 2010 North American Consensus guidelines and the 2007 European Association of Nuclear Medicine pediatric dosage card. These guidelines assign AA scaled to patient body mass, with further constraints on maximum and minimum values of radiopharmaceutical activity. These guidelines, however, are not formulated based upon a rigor-ous evaluation of diagnostic image quality. In a recent study of the renal cortex imaging agent 99mTc-DMSA (Li Y et al 2019), body mass-based dosing guidelines were shown to not give the same level of image quality for patients of differing body mass. Their data suggest that patient girth at the level of the kidneys may be a better morphometric parameter to consider when selecting AA for renal nuclear medicine imaging. The objective of the present work was thus to develop a dedicated series of computational phantoms to support image quality and organ dose studies in pediatric renal imaging using 99mTc-DMSA or 99mTc-MAG3. The final library consists of 50 male and female phantoms of ages 0 to 15 years, with percentile variations (5th to 95th) in waist circumference (WC) at each age. For each phantom, nominal values of kidney volume, length, and depth were incorporated into the phantom design. Organ absorbed doses, detriment-weighted doses, and stochastic risks were assessed using ICRP reference biokinetic models for both agents. In Monte Carlo radiation transport simulations, organ doses for these agents yielded detriment-weighted dose coefficients (mSv/MBq) that were in general larger than current ICRP values of the effective dose coefficients (age and WC-averaged ratios of eDW/e were 1.40 for the male phantoms and 1.49 for the female phantoms). Values of risk index (ratio of radiation-induced to natural background cancer incidence risk x 100) varied between 0.062 (newborns) to 0.108 (15-year-olds) for 99mTc-DMSA and between 0.026 (newborns) to 0.122 (15-year-olds) for 99mTc-MAG3. Using tallies of photon exit fluence as a rough surrogate for uniform image quality, our study demonstrated that through body region-of-interest optimization of AA, there is the potential for further dose and risk reductions of between factors of 1.5 to 3.0 beyond simple weight-based dosing guidance.

2 December 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JBJustin L Brown
Justin L Brown
BSBriana Sexton-Stallone
Briana Sexton-Stallone
YLYe Li
Ye Li
EFEric C Frey
Eric C Frey
STS Ted Treves
S Ted Treves
WBWesley E Bolch
Wesley E Bolch
Skeletal scintigraphy is most performed in pediatric patients using the radiopharmaceutical 99m Tc labelled methylene diphosphonate ( 99m Tc-MDP). Reference biokinetic models for 99m Tc-MDP indicate 50% of the administered activity is uniformly localized to the interior bone surfaces (trabecular and cortical regions), yet imaging data clearly show some preferential uptake to the epiphyseal growth plates of the long bones. To explore the dosimetric consequences of these regional activity concentrations, we have modified mesh-type computational phantoms of the International Commission on Radiological Protection (ICRP) reference pediatric series to explicitly include geometric models of the epiphyseal growth plates (2 mm in thickness) within the left/right, distal/proximal ends of the humeri, radii, ulnae, femora, tibia, and fibulae. Bone mineral activity from the ICRP Publication 128 biokinetic model for 99m Tc-MDP (ICRP 2015) was then partitioned to the growth plates at values of 0.5%, 4.4%, 8.3%, 12.2%, 16.1%, and 20%. Radiation transport simulations were performed to compute 99m Tc S-values and organ dose coefficients to the soft tissues and to bone site-specific regions of spongiosa. As the percentage of bone activity assigned to the growth plates was increased (from 0.5% to 20%), absorbed doses to the soft tissue organs, active bone marrow, bone endosteum (BE), as well as the detriment-weighted dose, were shown to decrease from their nominal values (no substantial growth plate activity), while epiphyseal plate self-doses increased. In the 15 year old male phantom, moving from 0.5% to 20% relative bone activity within the epiphyseal plates resulted in a 15% reduction in active marrow (AM) and BE dose, a 10% reduction in mean soft tissue and detriment-weighted dose, and a 6.3-fold increase in epiphyseal plate self-dose. In the newborn female phantom, we observed a 18% decrease in AM and BE dose, a 10% decrease in mean soft tissue dose, a 15% decrease in detriment-weighted dose, and 12.8-fold increase in epiphyseal plate self-dose. Increases (to 3 mm) and decreases (to 1 mm) in the assumed growth plate thickness of our models were shown to impact only the growth plate self-dose. Future work in differential quantification of 99m Tc-MDP activity—growth plates versus other bone surfaces—is required to provide clinically realistic data on activity partitioning as a function of patient age, and perhaps skeletal site. The phantom series presented here may be used to develop more optimized age-related guidance on 99m Tc-MDP administered activities to children.