Grant J. Smith

Grant J. Smith

Auto-generated profile, based on publicly available information

Grant J. Smith

Children's Diabetes Centre The Kids Research Institute Australia Nedlands Western Australia Australia

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2021 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
MBMarie-Anne Burckhardt
Marie-Anne Burckhardt
MAMary Binsu Abraham
Mary Binsu Abraham
JDJulie Dart
Julie Dart
GSGrant J. Smith
Grant J. Smith
NPNirubasini Paramalingam
Nirubasini Paramalingam
TJTimothy W. Jones
Timothy W. Jones
Objective: This study evaluated the efficacy of using a hybrid closed loop (HCL) system in restoring hypoglycemia awareness in individuals with impaired awareness of hypoglycemia (IAH). Research Design and Methods: Participants with IAH (Gold score ≥4) were recruited into a randomized crossover pilot study. They participated in two 8-week periods using a HCL system (Medtronic 670G™) (intervention) and standard insulin pump therapy (control). Hyperinsulinemic hypoglycemic clamp studies were undertaken at baseline and at the end of each study period for the evaluation of the counter-regulatory hormonal and symptomatic responses to hypoglycemia. Results: Seventeen participants (mean age [standard deviation] 35.8 years [11.2 years]) were included in the study. Peak epinephrine levels (median, interquartile range [IQR]) in response to hypoglycemia were similar postintervention and control periods; 234.7 pmol/L (109.2; 938.9) versus 188.3 pmol/L (133.7; 402.9), P = 0.233. However, both peak adrenergic and neuroglycopenic symptom scores were higher after intervention; 5.0 (4.5; 9.0) versus 4.0 (4.0; 5.5), P = 0.009, and 8.5 (6.0; 15.0) versus 6.5 (6.0; 7.0) P = 0.014, respectively. Self-reported hypoglycemia awareness improved: median (IQR) Gold score was 4.0 (3.0; 5.5) versus 5.5 (4.5; 6.0); intervention versus control, P = 0.033. Time spent <3.9 and <3.0 mmol/L was lower in the intervention group than in control, P = 0.002. Other patient-reported outcomes (hypoglycemia fear and diabetes treatment satisfaction) did not change. Conclusions: A short-term use of a HCL system failed to demonstrate an improvement in counter-regulatory hormonal responses. However, higher hypoglycemia symptom scores during controlled hypoglycemia, better self-reported hypoglycemia awareness, and less time spent in hypoglycemia suggest the potential benefits of a HCL system in people with IAH. Trial Registration: anzctr.org.au Identifier: ACTRN12616000909426.

30 April 2024 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
MAMary Binsu Abraham
Mary Binsu Abraham
GSGrant J. Smith
Grant J. Smith
JDJulie Dart
Julie Dart
EDElizabeth Davis
Elizabeth Davis
TJTimothy W. Jones
Timothy W. Jones
Advanced hybrid closed-loop (AHCL) therapy with the Medtronic MiniMed™ 780G system improves glycemia; however, the clinical outcomes in younger children remain less established. This pilot study aimed to explore the continuous glucose monitoring (CGM) metrics in very young children on AHCL. Children between 2 and 7 years of age and on insulin pump therapy were recruited. A 2-week phase in manual mode was followed by a 6-week AHCL phase. CGM metrics were analyzed to review glycemic outcomes. Out of 11 participants enrolled [mean (standard deviation [SD]) age 5.3 (0.8) years], 10 completed the study. Time in closed loop was 96.7 (3.9)%. In AHCL, participants had a mean (SD) time in range of 72.6 (7.4)% and spent 3.0 (1.74)% and 0.63 (0.46)% in time <70 and <54 mg/dL, respectively. AHCL is a feasible option for management of young children with type 1 diabetes.

14 October 2021 in JMIR Diabetes
Verified
Journal Article
Open access
VSVinutha B Shetty
Vinutha B Shetty
WSWayne H K Soon
Wayne H K Soon
ARAlison G Roberts
Alison G Roberts
LFLeanne Fried
Leanne Fried
HRHeather C Roby
Heather C Roby
EDElizabeth Davis
Elizabeth Davis
Background: Empowering young people with type 1 diabetes (T1D) to manage their blood glucose levels during exercise is a complex challenge faced by health care professionals due to the unpredictable nature of exercise and its effect on blood glucose levels. Mobile health (mHealth) apps would be useful as a decision-support aid to effectively contextualize a blood glucose result and take appropriate action to optimize glucose levels during and after exercise. A novel mHealth app acT1ve was recently developed, based on expert consensus exercise guidelines, to provide real-time support for young people with T1D during exercise. Objective: Our aim was to pilot acT1ve in a free-living setting to assess its acceptability and functionality, and gather feedback on the user experience before testing it in a larger clinical trial. Methods: A prospective single-arm mixed method design was used. Ten participants with T1D (mean age 17.7 years, SD 4.2 years; mean HbA1c, 54 mmol/mol, SD 5.5 mmol/mol [7.1%, SD 0.5%]) had acT1ve installed on their phones, and were asked to use the app to guide their exercise management for 6 weeks. At the end of 6 weeks, participants completed both a semistructured interview and the user Mobile Application Rating Scale (uMARS). All semistructured interviews were transcribed. Thematic analysis was conducted whereby interview transcripts were independently analyzed by 2 researchers to uncover important and relevant themes. The uMARS was scored for 4 quality subscales (engagement, functionality, esthetics, and information), and a total quality score was obtained from the weighted average of the 4 subscales. Scores for the 4 objective subscales were determined by the mean score of each of its individual questions. The perceived impact and subjective quality of acT1ve for each participant were calculated by averaging the scores of their related questions, but were not considered in the total quality score. All scores have a maximal possible value of 5, and they are presented as medians, IQRs, and ranges. Results: The main themes arising from the interview analysis were “increased knowledge,” “increased confidence to exercise,” and “suitability” for people who were less engaged in exercise. The uMARS scores for acT1ve were high (out of 5) for its total quality (median 4.3, IQR 4.2-4.6), engagement (median 3.9, IQR 3.6-4.2), functionality (median 4.8, IQR 4.5-4.8), information (median 4.6, IQR 4.5-4.8), esthetics (median 4.3, IQR 4.0-4.7), subjective quality (median 4.0, IQR 3.8-4.2), and perceived impact (median 4.3, IQR 3.6-4.5). Conclusions: The acT1ve app is functional and acceptable, with a high user satisfaction. The efficacy and safety of this app will be tested in a randomized controlled trial in the next phase of this study. Trial Registration: Australian New Zealand Clinical Trials Registry (ANZCTR) ACTRN12619001414101; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=378373

21 February 2023 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
GSGrant J. Smith
Grant J. Smith
MAMary Binsu Abraham
Mary Binsu Abraham
MBMartin Isaac de Bock
Martin Isaac de Bock
JFJanice Fairchild
Janice Fairchild
BKBruce R. King
Bruce R. King
TJTimothy W. Jones
Timothy W. Jones
Objective: To explore the impact of missing data on the accuracy of continuous glucose monitoring (CGM) metrics collected for a 2-week period in a clinical trial. Research Design and Methods: Simulations were conducted to examine the effect of various patterns of missingness on the accuracy of CGM metrics as compared with a “complete” data set. The proportion of missing data, the “block size” in which the data were missing, and the missing mechanism were modified for each “scenario.” The degree of agreement between simulated and “true” glycemic measures under each scenario was presented as R 2 . Results: Under all missing patterns, R 2 declined as the proportion of missing data increased, however, as the “block size” of missing data increased, the percentage of missing data had a more pronounced effect on the agreement between measures. For a 14-day CGM data set to be considered representative for percentage time in range (%TIR), at least 70% of CGM data should be available over at least 10 days ( R 2 > 0.9). Skewed outcome measures, such as percentage time below range and coefficient of variation, were more affected by missing data than the less skewed measures (%TIR, percentage time above range, mean glucose). Conclusions: Both the degree and pattern of missing data impact upon the accuracy of recommended CGM-derived glycemic measures. In planning research, an understanding of patterns of missing data in the study population is required to gauge the likely effects of missing data on outcome accuracy. Trial registration number: Australian New Zealand Clinic Trials Registry ACTRN12616000753459.

5 May 2021 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Closed access
PDF file
BKBarbara Keating
Barbara Keating
CSCarmel Elizabeth Smart
Carmel Elizabeth Smart
Amelia HarrayAmelia Harray
Amelia Harray
NPNirubasini Paramalingam
Nirubasini Paramalingam
GSGrant Smith
Grant Smith
EDElizabeth Davis
Elizabeth Davis
Context The pattern and quantity of insulin required for high-protein high-fat (HPHF) meals is not well understood. Objective This study aimed to determine the amount and delivery pattern of insulin required to maintain euglycemia for 5 hours after consuming a HPHF meal compared with a low-protein low-fat (LPLF) meal. Methods This randomized crossover clinical trial, conducted at 2 Australian pediatric diabetes centers, included 10 patients (12-21 years of age) with type 1 diabetes for ≥ 1 year. Participants were randomized to HPHF meal (60 g protein, 40 g fat) or LPLF meal (5 g protein, 5 g fat) with identical carbohydrate content (30 g). A modified insulin clamp technique was used to determine insulin requirements to maintain postprandial euglycemia for 5 hours. Total mean insulin requirements over 5 hours were measured. Results The total mean insulin requirements for the HPHF meal were significantly greater than for the LPLF meal (11.0 [CI 9.2, 12.8] units vs 5.7 [CI 3.8, 7.5] units; P = 0.001). Extra intravenous insulin was required for HPHF: 0 to 2 hours (extra 1.2 [CI 0.6, 1.6] units/h), 2 to 4 hours (extra 1.1 [CI 0.6, 1.6] units/h), and 4 to 5 hours (extra 0.6 [CI 0.1, 1.1] units/h) after the meal. There were marked inter-individual differences in the quantity of additional insulin (0.3 to 5 times more for HPHF) and the pattern of insulin delivery (0%-85% of additional insulin required in the first 2 hours). Conclusion The addition of protein and fat to a standardized carbohydrate meal almost doubled the mean insulin requirement, with most participants requiring half of the additional insulin in the first 2 hours.