The expansion of the road network requires the use of a large amount of natural resources. On the other hand, industrial development leads to the creation and deposition of a large amount of industrial waste. Large amounts of this waste accumulate in landfills close to the production process and represent a major environmental and economic problem, which can be solved by reusing industrial waste in the construction sector. Many researchers dealt with the topic of using copper slag as a partial replacement of natural aggregate in asphalt mixtures and as a result obtained favorable physical and mechanical characteristics of asphalt mixtures. One of the negative impacts of this alternative material is the high porosity of the slag, which required a higher amount of bitumen in the asphalt mixtures. However, this problem is solved by adding recycled asphalt (RAP-Recycled asphalt pavement) in the mixes.
Seismic analysis represents an important aspect of the design of building structures, aimed at ensuring their safety and adequate performance under earthquake loading. This paper presents an overview of seismic analysis methods in accordance with the requirements of EN 1998 (Eurocode 8). Four main methods are considered: linear static analysis using the equivalent lateral force procedure, linear dynamic analysis based on modal response spectrum analysis, nonlinear static (pushover) analysis, and nonlinear dynamic time-history analysis. For each method, the basic principles of analysis, main characteristics, advantages and limitations, as well as the conditions and possibilities of application depending on the complexity, regularity and dynamic characteristics of the structure, are discussed. Based on the considered characteristics, the importance of selecting an appropriate seismic analysis method in accordance with the requirements of the standard and the specific characteristics of the structure is highlighted.
This paper presents a comparative study of two linear seismic analysis methods according to Eurocode 8 requirements: the equivalent lateral force method and modal response spectrum analysis. A regular reinforced concrete frame structure (Ground + 4 stories) was analyzed using manual calculations and Tower 8 software. The fundamental periods of vibration and base shear forces obtained by both methods were compared. The results show a high level of agreement, while the equivalent lateral force method provides more conservative results due to the assumption of the dominant influence of the fundamental mode of vibration. The analysis highlights the simplicity of this method and the advantages of modal response spectrum analysis in representing structural behavior.
This paper presents a comparative analysis of the design and verification of an existing steel industrial building according to traditional JUS standards, based on the allowable stress method, and current Eurocode (EC) standards, based on the limit state concept. Although existing structures designed according to JUS standards have generally performed satisfactorily, stricter Eurocode load combinations, partial safety factors, and stability criteria may result in non-compliance with current requirements. The objective of this study is to identify the key differences between the two design approaches, determine the critical structural members that do not satisfy Eurocode requirements, and consider appropriate strengthening measures for adapting the existing structure to current engineering standards.
Corrosion-induced material loss can lead to significant degradation of the mechanical properties and load-bearing capacity of steel structural elements. The resulting material behaviour can be associated with the mechanisms of void nucleation, growth and coalescence characteristic of ductile fracture. This paper presents the implementation of a material damage model based on the Complete Gurson Model (CGM) in Abaqus/Standard using a user-defined UMAT subroutine. The implemented model incorporates the Gurson-Tvergaard-Needleman approach and the Thomason failure criterion, enabling the simulation of material degradation and ductile fracture. The input material parameters and state variables required for the numerical analysis are presented, together with the interaction procedure between Abaqus and the UMAT subroutine. The proposed implementation provides an extended material model for numerical analysis of steel elements affected by corrosion and other surface damage mechanisms.
Copper slag, produced as a by-product of the pyrometallurgical process of obtaining copper from copper ore in Bor, is disposed as waste in landfills. Despite the favorable physical and mechanical properties of concrete made with copper slag aggregate, such as higher compressive strength (40.8 MPa), higher tensile splitting strength (10.3 MPa), higher pull-off strength (3.1 MPa) and lower water permeability, its use in the construction industry has not been sufficiently investigated. The paper shows the possibility of using copper slag aggregate (CSA) in concrete as a potential replacement for natural river aggregate (RA).