In this paper we address several growing concerns of wind power integration from the perspective of power system dynamics and stability. We propose a new control design technique called retrofit control by which one can control the rotor voltages of doubly-fed induction generators inside individual wind farms to suppress the oscillations in the tie-line power flows caused by a disturbance inside the wind farm. The controller can be designed in a modular way, and also implemented in a completely decentralized fashion using only local feedback from the wind generator states and the voltage at the point of common coupling without depending on the states of any of the synchronous machines in the rest of the system. We show the effectiveness of the design using simulations of the IEEE 68- bus, 16-machine power system model with two wind farms.
29 May 2023 in IEEE Transactions on Control of Network Systems
Protecting the parameters, states, and input/output signals of a dynamic controller is essential for securely outsourcing its computation to an untrusted third party. Although a fully homomorphic encryption scheme allows the evaluation of controller operations with encrypted data, an encrypted dynamic controller with the encryption scheme destabilizes a closed-loop system or degrades the control performance due to overflow. This paper presents a novel controller representation based on input-output history data to implement an encrypted dynamic controller that operates without destabilization and performance degradation. Implementation of this encrypted dynamic controller representation can be optimized via batching techniques to reduce the time and space complexities. Furthermore, this study analyzes the stability and performance degradation of a closed-loop system caused by the effects of controller encryption. A numerical simulation demonstrates the feasibility of the proposed encrypted control scheme, which inherits the control performance of the original controller at a sufficient level.
29 September 2020 in IEEE Transactions on Control of Network Systems
In this paper, we propose a fast reinforcement learning (RL) control algorithm that enables online control of large-scale networked dynamic systems. RL is an effective way of designing model-free linear quadratic regulator (LQR) controllers for linear time-invariant (LTI) networks with unknown state-space models. However, when the network size is large, conventional RL can result in unacceptably long learning times. The proposed approach is to construct a compressed state vector by projecting the measured state through a projective matrix. This matrix is constructed from online measurements of the states in a way that it captures the dominant controllable subspace of the open-loop network model. Next, a RL-controller is learned using the reduced-dimensional state instead of the original state such that the resultant cost is close to the optimal LQR cost. Numerical benefits as well as the cyber-physical implementation benefits of the approach are verified using illustrative examples including an example of wide-area control of the IEEE 68-bus benchmark power system.
12 May 2022 in IEEE Transactions on Automatic Control
In the state-of-the-art literature on cryptography and control theory, there has been no systematic methodology of constructing cyber-physical systems that can achieve desired control performance while being protected against eavesdropping attacks. In this paper, we tackle this challenging problem. We first propose two novel notions referred to as sample identifying complexity and sample deciphering time in an encrypted-control framework. The former explicitly captures the relation between the dynamical characteristics of control systems and the level of identifiability of the systems while the latter shows the relation between the computation time for the identification and the key length of a cryptosystem. Based on these two tractable new notions, we propose a systematic method for designing the both of an optimal key length to prevent system identification with a given precision within a given life span of systems, and of an optimal controller to maximize both of the control performance and the difficulty of the identification. The efficiency of the proposed method in terms of security level and realtime-ness is investigated through numerical simulations. To the
26 August 2022 in IEEE Transactions on Automatic Control
This study shows that the informativity for the identification of partially observable systems is equivalent to that for designing dynamical measurement-feedback stabilizers. This finding is entirely different from the input-state case, where the direct data-driven design of state-feedback stabilizers requires less informativity than system identification. We derive the equivalence between the two types of informativity based on a newly introduced vector autoregressive with exogenous input (VARX) framework, which is suitable for time-domain analyses such as state-space models while directly representing input–output characteristics such as transfer functions. Moreover, we show a duality between the characterization of all VARX models explaining data and that of all VARX controllers stabilizing such VARX models.
We present a new optimal power flow (OPF) design that not only optimizes fuel cost but also enhances dynamic performance of a power system. Performance is quantified by the H2-norm of the transfer matrix from any disturbance input to a set of performance outputs, which in this case are chosen as the frequencies of the generators. The H2-norm models the attenuation of the frequency amplitudes following the disturbance, and thereby quantifies the amount of damping torque induced on the tie-line flows. The method, referred to as H2-power flow modification (H2-PFM) is carried out in two steps. First, the regular OPF is solved to obtain the optimal generator setpoints for active and reactive power dispatch. Second, the load setpoints are re-tuned to minimize the aforesaid H2-norm while keeping the generator setpoints fixed. In particular, manipulating the load reactive power in this way is found to reduce the norm remarkably, improving disturbance attenuation and damping. A gradient descent algorithm is proposed for this minimization. Results are validated using the 68-bus test system with a solar farm.