A very sensitive and selective procedure was developed for the determination of niclosamide based on square-wave voltammetry at a glassy carbon electrode. Cyclic voltammetry was used to investigate the electrochemical reduction of niclosamide at a glassy carbon electrode. Niclosamide was first irreversibly reduced from NO2 to NHOH at −0.659 V in aqueous buffer solution of pH 8.5. Reversible and well defined peaks at −0.164 V and −0.195 V (vs. Ag/AgCl) were obtained that are responsible for two electron peaks between NHOH and NO. Following optimisation of the voltammetric parameters, pH and reproducibility, a linear calibration curve over the range 5 × 10−8–1 × 10−6 mol dm−3 was achieved. The detection limit was found to be 2.05 × 10−8 mol dm−3 niclosamide. For eight successive determinations of 5 × 10−7 mol dm−3 niclosamide, a relative standard deviation of 2.4% was obtained. This voltammetric method was applied to the direct determination of niclosamide in tablets. The results of the analysis suggest that the proposed method has promise for the routine determination of niclosamide in the products examined.
1 January 2003 in Bulletin of the Chemical Society of Ethiopia
Phenol and chlorophenols were investigated using single-wall carbon nanotubes (SWCNT) and poly(3,4-ethylenedioxythiophene) (PEDOT) composite modified glassy carbon electrode (SWCNT/PEDOT/GCE) as a detector in flow injection system. Optimization of experimental variables such as the detection potential, flow rate, and pH of the carrier solution (0.1 M sodium acetate) for the determination of phenol (P), 4-chlorophenol (CP), 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP), and pentachlorophenol (PCP) were performed. Under these conditions, analytical parameters were calculated from the calibration curve of measured amperometric responses as a function of concentrations of phenol and chlorophenols. The designed electrode exhibited very good analytical performance. The designed electrode was tested with 20 repetitive injections of each analyte and showed good operational stability. The analytical performance of the SWCNT/PEDOT/GCE electrode under flow through conditions was tested and was found to be impressive. The electrode showed a wider dynamic range for the detection of phenol and chlorophenols with low limits of detection compared with other enzymatic and nonenzymatic sensors. These results suggest that the method is quite useful for the analysis and monitoring of phenols and chlorophenols.
Rare earth (R) ion-doped TiO2 nanocomposites (NCs) with general composition (R: Y, Yb, Gd; , 0.2) were synthesized through co-precipitation/hydrolysis (CPH). NC particles with average size of approximately a few tens of nm were obtained. Similar compositions of polycrystalline (PC) samples with larger particle size were also prepared employing solid state reaction (SSR) method. Visible light photocatalytic activity of all samples was investigated for degradation of Congo red (CR) dye. Both in terms of apparent rate constant () and percent degradation after 180 min (), all NCs produced significantly enhanced degradation as compared to pure TiO2 and PC samples. Best degradation of 95% ( value) resulted with composition of Y3+ doped NC with min−1. This was followed by of 85 and 80%, produced with Yb3+ and Gd3+ doped, NCs, at around and min−1, respectively. The observations clearly suggest that enhanced photocatalytic degradation of CR is directly related to smaller particle size of the catalysts. Moreover, the presence of rare earth ions in the composites facilitates further improvement of degradation efficiency through effective suppression of recombination.
10 July 2007 in Bulletin of the Chemical Society of Ethiopia
ELECTROCHEMICAL BEHAVIOUR AND VOLTAMMETRIC DETERMINATION OF GESHOIDIN AND ITS SPECTROPHOTOMETRIC AND ANTIOXIDANT PROPERTIES IN AQUEOUS BUFFER SOLUTIONS