Sandeep Kumar Kalva

Sandeep Kumar Kalva

Auto-generated profile, based on publicly available information

Sandeep Kumar Kalva

Department of BioSciences and Bioengineering, Indian Institute of Technology Bombay, Powai, Mumbai, India

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2022 in Science Advances
Verified
Journal Article
Open access
PWPaul Wrede
Paul Wrede
ODOleksiy Degtyaruk
Oleksiy Degtyaruk
SKSandeep Kumar Kalva
Sandeep Kumar Kalva
XDXosé Luis Deán-Ben
Xosé Luis Deán-Ben
UBUgur Bozuyuk
Ugur Bozuyuk
DRDaniel Razansky
Daniel Razansky
Mobile microrobots hold remarkable potential to revolutionize health care by enabling unprecedented active medical interventions and theranostics, such as active cargo delivery and microsurgical manipulations in hard-to-reach body sites. High-resolution imaging and control of cell-sized microrobots in the in vivo vascular system remains an unsolved challenge toward their clinical use. To overcome this limitation, we propose noninvasive real-time detection and tracking of circulating microrobots using optoacoustic imaging. We devised cell-sized nickel-based spherical Janus magnetic microrobots whose near-infrared optoacoustic signature is enhanced via gold conjugation. The 5-, 10-, and 20-μm-diameter microrobots are detected volumetrically both in bloodless ex vivo tissues and under real-life conditions with a strongly light-absorbing blood background. We further demonstrate real-time three-dimensional tracking and magnetic manipulation of the microrobots circulating in murine cerebral vasculature, thus paving the way toward effective and safe operation of cell-sized microrobots in challenging and clinically relevant intravascular environments.

28 February 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
NANavchetan Awasthi
Navchetan Awasthi
GJGaurav Jain
Gaurav Jain
SKSandeep Kumar Kalva
Sandeep Kumar Kalva
MPManojit Pramanik
Manojit Pramanik
PYPhaneendra K. Yalavarthy
Phaneendra K. Yalavarthy
Photoacoustic tomography (PAT) is a non-invasive imaging modality combining the benefits of optical contrast at ultrasonic resolution. Analytical reconstruction algorithms for photoacoustic signals require large number of data points for accurate image reconstruction. However, in practical scenarios, data is collected using limited number of transducers along with data being often corrupted with noise resulting in only qualitative images. Further, the collected boundary data is band-limited due to limited bandwidth of the transducer making the photoacoustic imaging with limited data being qualitative. In this work, a deep neural network based model with loss function being scaled root-mean-squared-error was proposed for super-resolution, denoising as well as bandwidth enhancement of the photoacoustic signals collected at the boundary of the domain. The proposed network has been compared with traditional as well as other popular deep learning methods in numerical as well as experimental cases and is shown to improve the collected boundary data in turn providing superior quality reconstructed photoacoustic image. The improvement obtained in the Pearson Correlation, Structural Similarity Index Metric and Root Mean Square Error was as high as 35.62%, 33.81% and 41.07% respectively for phantom cases and Signal to Noise Ratio improvement in the reconstructed photoacoustic images was as high as 11.65 dB for in-vivo cases as compared to reconstructed image obtained using original limited bandwidth data. Code is available at https://sites.google.com/site/sercmig/home/dnnpat.

2 November 2017 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
SGSreedevi Gutta
Sreedevi Gutta
VKVenkata Suryanarayana Kadimesetty
Venkata Suryanarayana Kadimesetty
SKSandeep Kumar Kalva
Sandeep Kumar Kalva
MPManojit Pramanik
Manojit Pramanik
SGSriram Ganapathy
Sriram Ganapathy
PYPhaneendra K. Yalavarthy
Phaneendra K. Yalavarthy
Photoacoustic (PA) signals collected at the boundary of tissue are always band-limited. A deep neural network was proposed to enhance the bandwidth (BW) of the detected PA signal, thereby improving the quantitative accuracy of the reconstructed PA images. A least square-based deconvolution method that utilizes the Tikhonov regularization framework was used for comparison with the proposed network. The proposed method was evaluated using both numerical and experimental data. The results indicate that the proposed method was capable of enhancing the BW of the detected PA signal, which inturn improves the contrast recovery and quality of reconstructed PA images without adding any significant computational burden.

1 August 2016 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
SKSandeep Kumar Kalva
Sandeep Kumar Kalva
MPManojit Pramanik
Manojit Pramanik
For a circular scanning geometry in photoacoustic tomography, the axial/radial resolution is spatially invariant and is not affected by the ultrasound transducer (UST, detector) aperture. However, the tangential resolution is dependent on the detector aperture size and it varies spatially. Many techniques were proposed to improve the tangential resolution, such as attaching a concave lens in front of the nonfocused transducer or using a virtual point detector. Both of these methods have difficulties. Therefore, a modified delay-and-sum reconstruction algorithm has been proposed which can be used together with a standard ultrasound detector (nonfocused) to improve the tangential resolution. In this work, we validate the modified delay-and-sum algorithm experimentally for both flat and cylindrically focused USTs. More than threefold improvement in tangential resolution is observed. It is also shown that the object shape is recovered with this modified algorithm, which is very helpful for diagnosis and treatment purposes.

20 December 2018 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SKSandeep Kumar Kalva
Sandeep Kumar Kalva
PUPaul Kumar Upputuri
Paul Kumar Upputuri
MPManojit Pramanik
Manojit Pramanik
Bulky, expensive Nd:YAG lasers are used in conventional photoacoustic tomography (PAT) systems, making them difficult to translate into clinics. Moreover, real-time imaging is not feasible when a single-element ultrasound transducer is used with these low-pulse-repetition-rate lasers (10–100 Hz). Low-cost pulsed laser diodes (PLDs) can be used instead for photoacoustic imaging due to their high-pulse-repetition rates and compact size. Together with acoustic-reflector-based multiple single-element ultrasound transducers, a portable desktop PAT system was developed. This second-generation PLD-based PAT achieved 0.5 s cross-sectional imaging time with high spatial resolution of ∼165  μm and an imaging depth of 3 cm. The performance of this system was characterized using phantom and in vivo studies. Dynamic in vivo imaging was also demonstrated by monitoring the fast uptake and clearance of indocyanine green in small animal (rat) brain vasculature.

24 December 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
JJJayaprakash Jeyaraju
Jayaprakash Jeyaraju
DSDween Sanny
Dween Sanny
SKSandeep Kumar Kalva
Sandeep Kumar Kalva
MPManojit Pramanik
Manojit Pramanik
PYPhaneendra K. Yalavarthy
Phaneendra K. Yalavarthy
Photoacoustic tomography involves reconstructing the initial pressure rise distribution from the measured acoustic boundary data. The recovery of the initial pressure rise distribution tends to be an ill-posed problem in the presence of noise and when limited independent data is available, necessitating regularization. The standard regularization schemes include Tikhonov, $\ell _{1}$ -norm, and total-variation. These regularization schemes weigh the singular values equally irrespective of the noise level present in the data. This paper introduces a fractional framework to weigh the singular values with respect to a fractional power. This fractional framework was implemented for Tikhonov, $\ell _{1}$ -norm, and total-variation regularization schemes. Moreover, an automated method for choosing the fractional power was also proposed. It was shown theoretically and with numerical experiments that the fractional power is inversely related to the data noise level for fractional Tikhonov scheme. The fractional framework outperforms the standard regularization schemes, Tikhonov, $\ell _{1}$ -norm, and total-variation by 54% in numerical simulations, experimental phantoms, and in vivo rat data in terms of observed contrast/signal-to-noise-ratio of the reconstructed images.