Isaac Phiri

Isaac Phiri

Auto-generated profile, based on publicly available information

Isaac Phiri

Ministry of Health and Child Welfare

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2017 in Parasites & Vectors
Verified
Journal Article
Open access
PDF file
MCMwelwa Chembensofu
Mwelwa Chembensofu
KMK. E. Mwape
K. E. Mwape
VIVan Damme Inge
Van Damme Inge
EHEmma C. Hobbs
Emma C. Hobbs
IPI. K. Phiri
I. K. Phiri
SGSarah Gabriël
Sarah Gabriël
Taenia solium is a neglected zoonotic parasite. The performances of existing tools for the diagnosis of porcine cysticercosis need further assessment, and their shortcomings call for alternatives. The objective of this study was to evaluate the performance of tongue palpation and circulating antigen detection for the detection of porcine cysticercosis in naturally infected pigs of slaughter age compared to full carcass dissections (considered the gold standard). Additionally, alternative postmortem dissection procedures were investigated. A total of 68 rural pigs of slaughter age randomly selected in the Eastern Province of Zambia were dissected. Dissections were conducted on full carcasses (or half carcass in case cysticerci were already detected in the first half), including all the organs. Total cysticercus counts, location and stages were recorded and collected cysticerci were identified morphologically and molecularly. All sera were analysed with the B158/B60 antigen detecting ELISA (Ag-ELISA). Key findings were the high occurrence of T. solium infected pigs (56%) and the presence of T. solium cysticerci in the livers of 26% of infected animals. More than half of the infected carcasses contained viable cysticerci. Seven carcasses had T. hydatigena cysticerci (10%), out of which five carcasses were co-infected with T. hydatigena and T. solium; two carcasses (3%) had only T. hydatigena cysticerci. Compared to full carcass dissection, the specificity of the Ag-ELISA to detect infected carcasses was estimated at 67%, the sensitivity at 68%, increasing to 90% and 100% for the detection of carcasses with one or more viable cysticerci, and more than 10 viable cysts, respectively. Tongue palpation only detected 10% of the cases, half carcass dissection 84%. Selective dissection of the diaphragm, tongue and heart or masseters can be considered, with an estimated sensitivity of 71%, increasing to 86% in carcasses with more than 10 cysticerci. Depending on the aim of the diagnosis, a combination of Ag-ELISA and selective dissection, including investigating the presence of T. hydatigena, can be considered. Full carcass dissection should include the dissection of the liver, kidneys, spleen and lungs, and results should be interpreted carefully, as small cysticerci can easily be overlooked.

15 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
CMChishimba Mubanga
Chishimba Mubanga
VIVan Damme Inge
Van Damme Inge
CTChiara Trevisan
Chiara Trevisan
VSVeronika Schmidt
Veronika Schmidt
IPIsaac K. Phiri
Isaac K. Phiri
SGSarah Gabriël
Sarah Gabriël
The lack of cheap, easy-to-use, rapid diagnostic tests has led to the development of several rapid diagnostic tests for cysticercosis. The new prototype two-strip, Taenia solium point of care test (TS POC) detects antibodies against taeniosis (TS POC T) and cysticercosis (TS POC CC). This study evaluated the diagnostic performance of the TS POC CC in the Sinda district in eastern Zambia. A sample of 1254 participants was recruited and tested with the TS POC. Out of the 1249 participants with a valid TS POC result, 177 (14%) tested positive while 1072 (86%) tested negative. All individuals with a positive TS POC and a subset of negative TS POC participants were selected for serum sampling, and were subjected to the recombinant glycoprotein T24H enzyme-linked immunoelectrotransfer blot (rT24H EITB) and the serum B60/158 (serum Ag) enzyme-linked immunosorbent assay (Ag ELISA). Performance characteristics were estimated using a Bayesian approach with probabilistic constraints. Based on 255 complete cases, the estimated sensitivity and specificity of the TS POC CC test were 35% (95% CI: 14–63%) and 87% (95% CI: 83–90%), respectively. The diagnostic performance needs to be improved, possibly by titrating antigen and other reagents’ concentration in the strip to produce a performance similar to existing cysticercosis tests such as the rT24H EITB.

22 June 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
VIVan Damme Inge
Van Damme Inge
CTChiara Trevisan
Chiara Trevisan
KMKabemba Mwape
Kabemba Mwape
VSVeronika Schmidt
Veronika Schmidt
PMPascal Magnussen
Pascal Magnussen
OCon behalf of the SOLID Consortium
on behalf of the SOLID Consortium
Field-applicable, high-quality, and low-cost diagnostic tools are urgently needed for Taenia solium. The aim of this paper is to describe the design, challenges, and rationale for the design of a diagnostic accuracy study in low-resource community settings in Zambia. The trial was designed as a prospective study with a two-stage design to evaluate a new point-of-care test (TS POC) for the detection of taeniosis and (neuro)cysticercosis. Participants within randomly selected households were tested with the TS POC test (index test). Participants who tested TS POC positive for taeniosis and/or cysticercosis and a subset of the negatives were requested to give blood and stool samples for reference testing, and to undergo clinical examination and a cerebral CT scan. The difficulties of conducting a clinical trial in settings with limited research and neuroimaging infrastructure as well as peculiarities specifically related to the disease (low prevalence of taeniosis and the lack of a gold standard) were taken into consideration for the design of this study. The two-stage design increased the efficiency of the study by reducing the number of samples, clinical examinations, and CT scans. Simplified flows and sampling processes were preferred over complex follow-up and randomization systems, aiming to reduce bias and increase the generalizability of the study.

4 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
CMChishimba Mubanga
Chishimba Mubanga
CTChiara Trevisan
Chiara Trevisan
VIVan Damme Inge
Van Damme Inge
VSVeronika Schmidt
Veronika Schmidt
IPIsaac K. Phiri
Isaac K. Phiri
SGSarah Gabriël
Sarah Gabriël
Taenia solium taeniosis diagnosis is challenging because current tests perform sub-optimally and/or are expensive, require sophisticated equipment, infrastructure and trained manpower, and therefore are not community deployable. A recently-developed, multi-strip, T. solium point-of-care test (TS POC) for simultaneous detection of tapeworm (TS POC T) and cysticercus (TS POC CC) human antibodies was evaluated for diagnostic accuracy on consecutively recruited community participants in Sinda district, Zambia. All participants were tested using the TS POC test. All test-positives and 20% of the test-negative participants were invited to give a blood and stool sample for reference testing. Three different reference tests were used for taeniosis diagnosis: recombinant rES33 enzyme-linked immunoelectrotransfer blot (rES33 EITB), copro PCR and copro Ag ELISA. Bayesian analysis with probabilistic constraints was used to estimate sensitivity and specificity. In total, 1254 participants were tested with the TS POC test, of whom 13 tested positive using the TS POC T. Based on 161 participants with complete data, the estimated sensitivity and specificity for the TS POC T test were 38% (95% CI: 5–93%) and 99% (95% CI: 98–100%), respectively. The challenge of highly variable inter-assay performance is highlighted. We recommend either increasing the sensitivity or redesigning the test.

28 February 2021 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Open access
PDF file
TMTapfumanei Mashe
Tapfumanei Mashe
PLPimlapas Leekitcharoenphon
Pimlapas Leekitcharoenphon
SMSekesai Mtapuri-Zinyowera
Sekesai Mtapuri-Zinyowera
RKRobert Kingsley
Robert Kingsley
VRV Robertson
V Robertson
MEMarthie M Ehlers
Marthie M Ehlers
J Antimicrob Chemother 2021; 76: https://doi.org/10.1093/jac/dkaa519

17 October 2022 in Communicare: Journal for Communication Studies in Africa
Verified
Journal Article
Open access
PDF file
IPIsaac Phiri
Isaac Phiri
The disintegration of military regimes and one-party rule occurring across Africa in the early1990s allowed for the mushrooming of numerous new media initiatives and the resuscitationof hitherto dormant media operations. The enthusiasm was fuelled by promises of freedom ofspeech and prospects of the media becoming an autonomous fourth actor on the public stage. Itwas envisioned by many that the media would reject the ethos prevailing under hegemonic ruleand adopt international norms. But nearly two decades later, media people and their organisationsin sub-Saharan Africa are still entangled in a labyrinth of ethical dilemma. One of the big issuesbegging further research and reflection is whether to localise or globalise ethical discourse andpractice. How far should indigenous cultural values inform journalism ethics? And, how can thisbe negotiated in a rapidly globalising environment? This paper uses the Zambian experienceto advance the position that glocalisation - the hybridisation of ethical norms between the localand the global -provides the most enduring and acceptable foundation for ethical theorising andpractice available to media professionals on the continent.