27 June 2023 in International Transactions on Electrical Energy Systems
In this paper, the development and application of the radial basis function-finite difference (RBF-FD) method and the RBF-finite difference time domain (RBF-FDTD) method for solving electrical transient problems in power systems that are defined by the time-dependent ordinary differential equations (ODEs) and the time-dependent partial differential equations (PDEs), respectively, are presented. RBFs such as Gaussian (GA), Multiquadric (MQ), Inverse Quadric (IQ), and Inverse Multiquadric (IMQ) are used in these numerical methods to formulate the central finite difference approximations of the first- and second-order derivatives of a function. The algorithm of selecting “optimal” shape parameters for our basis functions is also applied, specifically to increase the accuracy of the suggested methods with regard to high accuracy needs. Finally, the accuracy, effectiveness, and applicability of our new approaches are evaluated through simulations of the switching transient voltages on a typical electrical circuit and a 220 kV single-phase transmission line, lightning-induced voltages on a 110 kV single-phase overhead distribution line, and transient voltages along two horizontal grounding electrodes excited by lightning impulse sources. The obtained numerical results demonstrate that our proposed RBF-based numerical approaches compare favorably to the traditional numerical methods.
11 July 2025 in IEEE Access
This paper presents an advanced application of the Radial Basis Function–Finite-Difference Time-Domain (RBF-FDTD) method, as introduced in [1], to solve the field-to-line coupling equations for simulating lightning-induced voltages on overhead distribution lines. Simulation results for a typical 1-km, 110-kV line obtained using both the RBF-FDTD and conventional FDTD methods are compared against benchmark solutions from the Lightning-Induced Overvoltage (LIOV) software to validate accuracy and determine the optimal shape parameters for the RBFs. The RBF-FDTD method exhibits high accuracy and reduced numerical dispersion, particularly when the shape parameters are optimally selected. Furthermore, the effects of critical physical factors—including lightning electromagnetic field models, imperfect ground conductivity, and corona discharge dynamics—on the induced voltages are analyzed through error evaluation. The results confirm the proposed method’s capability for reliable and efficient simulation of lightning transients, providing valuable insights for the design and protection of power distribution systems against fast transient overvoltages.
1 January 2026 in VNUHCM Journal of Engineering and Technology
This paper presents a new simulation approach for electromagnetic transient analysis on lossy transmission lines, based on combining the Radial Basis Function-based Finite-Difference Time-Domain (RBF‑FDTD). The proposed method overcomes limitations of the traditional FDTD scheme, which relies on Taylor-series-based finite-difference operators, by employing RBFs to construct more flexible and accurate numerical approximations. A new algorithm is introduced to determine the optimal RBF shape parameter, enabling a balanced trade-off between accuracy, numerical stability, and computational efficiency. The algorithm minimizes local approximation error through the use of a weight matrix and Taylor expansion, allowing the optimal parameter to be identified without requiring an exact reference solution. The RBF‑FDTD method is validated through multiple transmission-line models under different loading conditions, including resistive, parallel RC, RL, and parallel RLC terminations. Simulation results demonstrate that the method accurately reproduces transient waveforms, closely matching reference solutions in terms of amplitude, reflection timing, and resonant characteristics, while maintaining numerical stability in the presence of losses. Compared with the conventional FDTD method, RBF‑FDTD shows clear advantages in modeling nonuniform or distributed-parameter structures where high accuracy in spatial derivative approximation is required. These findings confirm the potential of RBF‑FDTD as a powerful and efficient tool for transient analysis in power systems, and highlight its applicability to more complex configurations such as branched transmission networks, grounding systems, and lightning-induced transients.