Duc-Quang Vu

Duc-Quang Vu

Auto-generated profile, based on publicly available information

Duc-Quang Vu

Ho Chi Minh City University of Technology, VNU-HCM, Ho Chi Minh City, Vietnam

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2023 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
DVDuc-Quang Vu
Duc-Quang Vu
NNNhat Nam Nhat Nguyen
Nhat Nam Nhat Nguyen
PVPhan-Tu Vu
Phan-Tu Vu
In this paper, the development and application of the radial basis function-finite difference (RBF-FD) method and the RBF-finite difference time domain (RBF-FDTD) method for solving electrical transient problems in power systems that are defined by the time-dependent ordinary differential equations (ODEs) and the time-dependent partial differential equations (PDEs), respectively, are presented. RBFs such as Gaussian (GA), Multiquadric (MQ), Inverse Quadric (IQ), and Inverse Multiquadric (IMQ) are used in these numerical methods to formulate the central finite difference approximations of the first- and second-order derivatives of a function. The algorithm of selecting “optimal” shape parameters for our basis functions is also applied, specifically to increase the accuracy of the suggested methods with regard to high accuracy needs. Finally, the accuracy, effectiveness, and applicability of our new approaches are evaluated through simulations of the switching transient voltages on a typical electrical circuit and a 220 kV single-phase transmission line, lightning-induced voltages on a 110 kV single-phase overhead distribution line, and transient voltages along two horizontal grounding electrodes excited by lightning impulse sources. The obtained numerical results demonstrate that our proposed RBF-based numerical approaches compare favorably to the traditional numerical methods.

11 July 2025 in IEEE Access
Verified
Journal Article
Open access
DVDuc-Quang Vu
Duc-Quang Vu
NNNhat Nam Nhat Nguyen
Nhat Nam Nhat Nguyen
TLTinh-Minh T. Le
Tinh-Minh T. Le
PVPhan-Tu Vu
Phan-Tu Vu
This paper presents an advanced application of the Radial Basis Function–Finite-Difference Time-Domain (RBF-FDTD) method, as introduced in [1], to solve the field-to-line coupling equations for simulating lightning-induced voltages on overhead distribution lines. Simulation results for a typical 1-km, 110-kV line obtained using both the RBF-FDTD and conventional FDTD methods are compared against benchmark solutions from the Lightning-Induced Overvoltage (LIOV) software to validate accuracy and determine the optimal shape parameters for the RBFs. The RBF-FDTD method exhibits high accuracy and reduced numerical dispersion, particularly when the shape parameters are optimally selected. Furthermore, the effects of critical physical factors—including lightning electromagnetic field models, imperfect ground conductivity, and corona discharge dynamics—on the induced voltages are analyzed through error evaluation. The results confirm the proposed method’s capability for reliable and efficient simulation of lightning transients, providing valuable insights for the design and protection of power distribution systems against fast transient overvoltages.

10 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
DVDuc-Quang Vu
Duc-Quang Vu
NNNhat Nam Nhat Nguyen
Nhat Nam Nhat Nguyen
PVPhan-Tu Vu
Phan-Tu Vu
Lightning-induced voltages on overhead distribution lines present a formidable obstacle to ensuring the reliability of power systems, evaluated through conventional numerical techniques, such as the Finite Difference Time Domain (FDTD) method and the Finite Element Time Domain (FETD) method. This study proposes a novel implementation of the Radial Basis Function-Finite Difference Time Domain (RBF-FDTD) method, extending the foundation of our previous work to address the field-to-line coupling equations governing such systems. The effectiveness and accuracy of this approach are rigorously validated through RBF-FDTD numerical simulations, applied to both horizontal and vertical configurations of a 1 km, 110 kV multi-conductor distribution line, as well as a real-world three-phase overhead line in Vietnam. In this study, the impact of various parameters, including line geometry, the presence of ground wires, and the influence of perfectly and imperfectly conducting ground, on the lightning-induced voltages are investigated. The simulation and computational results are in good agreement with findings from prior studies, underscoring the potential of the RBF-FDTD method as a robust tool of practical implications.

1 January 2026 in VNUHCM Journal of Engineering and Technology
Verified
Journal Article
Open access
PDF file
QVQuang Duc Vu
Quang Duc Vu
BNBinh Xuan Nguyen
Binh Xuan Nguyen
NNNam Nhat Nguyen
Nam Nhat Nguyen
TVTu Phan Vu
Tu Phan Vu
This paper presents a new simulation approach for electromagnetic transient analysis on lossy transmission lines, based on combining the Radial Basis Function-based Finite-Difference Time-Domain (RBF‑FDTD). The proposed method overcomes limitations of the traditional FDTD scheme, which relies on Taylor-series-based finite-difference operators, by employing RBFs to construct more flexible and accurate numerical approximations. A new algorithm is introduced to determine the optimal RBF shape parameter, enabling a balanced trade-off between accuracy, numerical stability, and computational efficiency. The algorithm minimizes local approximation error through the use of a weight matrix and Taylor expansion, allowing the optimal parameter to be identified without requiring an exact reference solution. The RBF‑FDTD method is validated through multiple transmission-line models under different loading conditions, including resistive, parallel RC, RL, and parallel RLC terminations. Simulation results demonstrate that the method accurately reproduces transient waveforms, closely matching reference solutions in terms of amplitude, reflection timing, and resonant characteristics, while maintaining numerical stability in the presence of losses. Compared with the conventional FDTD method, RBF‑FDTD shows clear advantages in modeling nonuniform or distributed-parameter structures where high accuracy in spatial derivative approximation is required. These findings confirm the potential of RBF‑FDTD as a powerful and efficient tool for transient analysis in power systems, and highlight its applicability to more complex configurations such as branched transmission networks, grounding systems, and lightning-induced transients.