Gilles Pasquier

Gilles Pasquier

Auto-generated profile, based on publicly available information

Gilles Pasquier

Université Lille-Hauts de France, 59000 Lille, France; Department of Orthopaedic and Traumatology, Lille University Hospital, 2 avenue Émile Laine, 59000 Lille, France

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2010 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
GPG. Pasquier
G. Pasquier
GDG. Ducharne
G. Ducharne
EAE. Sari Ali
E. Sari Ali
FGF. Giraud
F. Giraud
AMA. Mouttet
A. Mouttet
EDE. Durante
E. Durante

1 November 2021 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
JLJean-Thomas Leclerc
Jean-Thomas Leclerc
JDJulien Dartus
Julien Dartus
JLJulien Labreuche
Julien Labreuche
PMPierre Martinot
Pierre Martinot
RGRomain Galmiche
Romain Galmiche
SPSophie Putman
Sophie Putman

1 June 2019 in EFORT Open Reviews
Verified
Journal Article
Open access
GPGilles Pasquier
Gilles Pasquier
MEMatthieu Ehlinger
Matthieu Ehlinger
DMDidier Mainard
Didier Mainard
Hinged implants are the most constrained knee replacement prostheses. They are very useful in complex cases of total knee arthroplasty (TKA) revision. Hinged implants have evolved with rotating bearings and modularity that allows local joint reconstruction or segmental bone replacement. They are required when significant instability persists in cases with inadequate collateral ligaments and significant flexion laxity. They are now used when a large bone defect is reconstructed, or when bone fixation of the implant is questionable especially in the metaphyseal zone. The use of hinged implants in TKA revision is associated with high complication rates. Published outcomes differ based on the patients’ aetiology. The outcomes of rotating-hinged implants used in septic revisions or salvage situations are poorer than other types of revision and have a higher complication rate. The poor general health of these patients is often a limitation. Despite these relatively poor results, hinged implants continue to have a place in revision surgery to solve major instability or to obtain stable bone fixation of an implant when the metaphysis is filled with bone grafts or porous devices. Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180070

1 February 2020 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
GPGilles Jean Marie Pasquier
Gilles Jean Marie Pasquier
DHDenis Huten
Denis Huten
HCHarold Common
Harold Common
HMHenri Migaud
Henri Migaud
SPSophie Putman
Sophie Putman

1 June 2018 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
BVB. de Saint Vincent
B. de Saint Vincent
HMH. Migaud
H. Migaud
ESE. Senneville
E. Senneville
CLC. Loiez
C. Loiez
GPG. Pasquier
G. Pasquier
SPS. Putman
S. Putman

1 May 2021 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
ÉCÉtienne Caron
Étienne Caron
AGAntoine Gabrion
Antoine Gabrion
MEMatthieu Ehlinger
Matthieu Ehlinger
NVNicolas Verdier
Nicolas Verdier
BRBrice Rubens-Duval
Brice Rubens-Duval
GPGilles Pasquier
Gilles Pasquier