Linda Rudmann

Linda Rudmann

Auto-generated profile, based on publicly available information

Linda Rudmann

Laboratory for Biomedical Microtechnology Department of Microsystems Engineering University of Freiburg 79110 Freiburg Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LRL. Rudmann
L. Rudmann
Michael LangenmairMichael Langenmair
Michael Langenmair
BHB. Hahn
B. Hahn
JOJ.S. Ordonez
J.S. Ordonez
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz

15 February 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MEMax Eickenscheidt
Max Eickenscheidt
THThoralf Herrmann
Thoralf Herrmann
MWMarius Weisshap
Marius Weisshap
AMAnnette Mittnacht
Annette Mittnacht
LRLinda Rudmann
Linda Rudmann
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz

28 April 2024 in Advanced Healthcare Materials
Verified
Journal Article
Open access
LRLinda Rudmann
Linda Rudmann
DSDaniel Scholz
Daniel Scholz
MAMarie T. Alt
Marie T. Alt
ADAlexander Dieter
Alexander Dieter
EFEva Fiedler
Eva Fiedler
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz
With the growth of optogenetic research, the demand for optical probes tailored to specific applications is ever rising. Specifically, for applications like the coiled cochlea of the inner ear, where planar, stiff, and nonconformable probes can hardly be used, transitioning from commonly used stiff glass fibers to flexible probes is required, especially for long‐term use. Following this demand, polydimethylsiloxane (PDMS) with its lower Young's modulus compared to glass fibers can serve as material of choice. Hence, the long‐term usability of PDMS as a waveguide material with respect to variations in transmission and refractive index over time is investigated. Different manufacturing methods for PDMS‐based flexible waveguides are established and compared with the aim to minimize optical losses and thus maximize optical output power. Finally, the waveguides with lowest optical losses (−4.8 dB cm−1 ± 1.3 dB cm−1 at 472 nm) are successfully inserted into the optogenetically modified cochlea of a Mongolian gerbil (Meriones unguiculatus), where optical stimuli delivered by the waveguides evoked robust neuronal responses in the auditory pathway.

1 October 2014 in International Symposium on Microelectronics
Verified
Journal Article
Closed access
LRLinda Rudmann
Linda Rudmann
JOJuan S. Ordonez
Juan S. Ordonez
HZHans Zappe
Hans Zappe
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz
Within this paper a novel approach for the development of hermetic electrical feedthroughs is introduced. So far, every vertical feedthrough induces at the feedthroughs' interfaces possible paths for water to leak across the hermetic barrier into the hermetic package. The presented approach is based on the diffusion of platinum into silicon, locally changing the electrical behavior of the substrate due to the induced impurities. This method avoids destroying the bulk material, in this case silicon, preserving the hermetic barrier environment. Different n-type silicon substrates were investigated for their usability through various diffusion experiments under two gas atmospheres: Argon/hydrogen and pure nitrogen. A significant change in silicon behavior could be shown for one of the used substrates. The current flowing through the bulk could be decreased by a factor of around 12 for an argon/hydrogen atmosphere and by around 10 for pure nitrogen. The current directly correlates with a local increase of the substrates' resistance, demonstrating the possibility of adapting the electrical properties of a substrate to create insulating areas within a conductive substrate.

20 March 2023 in Advanced Materials Technologies
Verified
Journal Article
Open access
LRLinda Rudmann
Linda Rudmann
SHSebastian D. Huber
Sebastian D. Huber
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz
Electrical feedthroughs are a major part of active implantable medical devices. They are responsible for connecting the implants’ active sites with the processing electronics that are usually hermetically packaged. They deliver conductive pathways through the package wall and have to avoid premature device failure due to ingressing humidity. With decreasing device size, the requirements on the single parts increase, including the electrical feedthroughs. As conventional electrical feedthroughs rely on opening the hermetic bulk material of the package that introduce leak paths, they always raise the potential that water enters the package inside alongside these interfaces. Therefore, a proof‐of‐concept study of a new hermetic electrical feedthrough design that leaves the hermetic bulk material, that is, silicon, intact is presented. The concept is based on diffusing noble metals, Pt and Au, into the semiconductor bulk, resulting in a quasi‐localized resistance increase of the silicon. It is shown that by variation of diffusion temperature, time, the substrate cooling, and others, a parameter combination is found with which optoelectronic components can be driven through an intact silicon substrate.