1 June 2020 in Korean Journal of Anesthesiology
Mis-transfusion of blood components triggering serious complications are mostly due to preventable clerical errors, especially pre-transfusion misidentification of patient/blood unit at bedside. Recommendations for standard identity check is by electronic devices like barcode scanners. Establishments unable to afford these gadgets (e.g. economically poorer countries) perform identity check subjectively through visual judgement. This is prone to errors precipitating tremendous anxiety in personnel transfusing blood unit. Hence a novel objective method for pre-transfusion identity check-"Sandesh Positive-Negative (SPON) Protocol" was evaluated. A non-randomized study on bedside pre-transfusion identity check in terms of anxiety, satisfaction and errors occurred was conducted. 75 subjects performed transfusion (Consultants, postgraduates and nurses). Intervention was accomplished by matching a custom made negative label arriving with blood component with the positive label of the same patient available at bedside who is about to receive transfusion. 85.3% subjects were anxious about pre-transfusion identity check with existing standard practice. After implementation of SPON protocol, only 38.7% had either mild or severe anxiety (p< 0.05) and none of them were dissatisfied. Overall level of satisfaction also increased with number of subjects being highly satisfied rising to 38.7% from 8.0% (p<0.05). Although only 9.3% were dissatisfied about prevailing practice, about 70.7% felt need for a better/additional protocol. There was no occurrence of clerical error. SPON protocol is a cost effective objective technique for final bedside identity check of blood components which reduces anxiety and increases satisfaction levels.
2 July 2022 in Pediatric Anesthesia
27 March 2023 in Ain-Shams Journal of Anesthesiology
Background: Supraglottic airway devices (SADs) are the mainstay for airway management in pediatric ambulatory surgeries and may often be a suitable alternative to endotracheal intubation due to their favorable profile. Optimal oropharyngeal leak pressure of SAD is essential for adequate ventilation and prevention of aspiration. Occasionally, lateral position is required for administration of regional block or for the surgery itself. We aim to compare the oropharyngeal leak pressure of igel™ and LMA Supreme™ in children in lateral position. A prospective, randomized study was performed on eighty children of either sex, weighing 5–10 kg, belonging to ASA grade I and II undergoing elective surgery requiring lateral position. The primary objective was comparison of Oropharyngeal leak pressure of both devices in lateral position. Secondary objectives included assessment of insertion success rate, number of insertion attempts and manipulations, time and ease of insertion; and comparison of fiberoptic view of the larynx, fractional volume loss, and displacement with respect to both devices in supine and lateral position. Results: Oropharyngeal leak pressure of i-gel™ was higher than that of LMA Supreme™ in both supine (25.4 ± 1.4 cm H2O Vs 22.9 ± 1.5 cm H2O) and lateral position (23.9 ± 1.6 vs 21.5 ± 1.5 cm H2O) and was statistically significant (p < 0.001). The success rate of insertion of i-gel™ and LMA Supreme™ was similar (95% and 97.5% respectively). The ease of insertion for both devices was statistically similar (p = 0.593). The mean time for insertion was longer for i-gel™ (15.4 ± 1.72 s vs 12.4 ± 1.73 s) as compared to LMA Supreme™ (p < 0.001). Ventilatory parameters for both devices decreased in the lateral position, which was statistically significant. The fractional volume loss after change of position was 0.123 vs 0.478 for i-gel™ and LMA Supreme™ respectively. In both groups, fiberoptic views worsened with a change of position. Conclusions: Oropharyngeal leak pressure of both devices reduced in lateral position as compared to supine position. I-gel™ yielded higher leak pressures in supine as well as in lateral position as compared to LMA Supreme™. Implications: The above findings offer valuable insight for decision-making in pediatric daycare surgeries requiring lateral position where GA is warranted. Trial registration: CTRI NUMBER (CTRI/2021/01/030442)—the trial was registered with the Clinical Trial Registry of India on 13 January 2021.
19 November 2020 in Southern African Journal of Anaesthesia and Analgesia
The benefits of regional anaesthesia and the accompanying concerns of general anaesthesia in newborns make the former a safe and valuable addition. Multiple regional anaesthesia techniques, ranging from the central neuraxial blocks, truncal blocks, and peripheral nerve blocks are available. Empowering us to make the case to case decision to choose the most beneficial and safe block for the neonate. The applications of regional anaesthesia, over the period, have encompassed perioperative analgesia and therapeutic uses. With the addition of ultrasonography, neonatal regional anaesthesia has reached a fine amount of objectivity and accuracy. A trend of utilising regional blocks as the sole anaesthetic as against an adjuvant to general anaesthesia is setting in. In this review, we take a look at recent developments in this field in a generalised manner followed by dwelling into most of the commonly used blocks in daily practice. However, a detailed description of each block is beyond the scope of this review.
15 March 2024 in Indian Journal of Clinical Anaesthesia
A retrospective analysis of anesthetic techniques and their related perioperative complications in children undergoing cochlear implant surgeries – our preliminary experience at a tertiary care referral centre - IJCA- Print ISSN No: - 2394-4781 Online ISSN No:- 2394-4994 Article DOI No:- 10.18231/j.ijca.2024.003, Ind