This paper presents a complete approach for switched reluctance generator (SRG) in variable wind energy conversion systems. Two forms of direct power control (DPC) and a commutative system that allows SRG performance at a wide range of speed variations are proposed. Thus, more mechanical energy can be captured in wind generation. In the proposed structure, the SRG operates in a self-excited mode using a common dc bus system of a voltage source inverter connected to an electrical grid. DPCs are proposed by hysteresis of the SRG phase current for low-speed operation (DPC-LS) and by a single pulse of current for high-speed operation (DPC-HS). The low-pass filter employed to obtain the average power generated may slow down the response of the control system of the DPC applied to SRG. To improve the system performance, sliding mode controllers in DPCs were used. For operation throughout a wide speed range, the DPC-LS and DPC-HS controls should be joined. Therefore, a commutative system with smooth transition between DPC modes is proposed. Finally, simulations and experimental tests were conducted to verify the behavior of the proposed arrangement. The results confirmed correct operation of the proposed system.
This article presents a high resolution automatic system capable of performing magnetic characterization tests and obtaining the data needed to conduct reliable models for switched reluctance machines (SRM). In addition, the detailed description of the instrumentation system performed in this work has as contribution the study of mathematical interpolation techniques for the treatment process of test data to obtain a nonlinear model based on lookup tables. It was observed that the commonly used polynomial regressions may cause inaccuracies in the final characteristics of the model data. Thereat, smoothing splines were applied, which results in more accurate and consistent results for the SRMs operation. Thus, it is possible to obtain control projects, optimization systems and advanced studies through computer simulations. Simulation and experimental results have proved the efficiency of the system and have confirmed the importance of achieving real curves when accurate models of a SRM are needed.
The number of photovoltaic distributed generators introduced into electricity distribution systems is increasing worldwide. Safety measures must be taken for the correct operation of these new distributed generators so as to prevent uncontrolled and undesired power injections into the grid and possible damages to equipment and personnel. This paper describes an anti-islanding detection method used for prevention against unintentional islanding of the distributed generator. The main focus is the study, implementation and analysis of the Sandia Frequency Shift method based on the IEEE 929-2000 standard.