Estefania Suarez Perez

Estefania Suarez Perez

Auto-generated profile, based on publicly available information

Estefania Suarez Perez

Medical Robotics and Biosignals Laboratory, UPIBIInstituto Politcnico Nacional, Mexico City, Mexico

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2026 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
MGManuela Gomez-Correa
Manuela Gomez-Correa
HPHellen Romina Rivero Pineda
Hellen Romina Rivero Pineda
ESEstefania Suarez-Perez
Estefania Suarez-Perez
DCDavid Cruz-Ortiz
David Cruz-Ortiz
MBMariana Ballesteros
Mariana Ballesteros
This paper describes motion assessment in young adults (YA) and older adults (OA) during the use of an upper limb rehabilitation robot (ULRR). An experimental protocol was proposed to collect kinematic and surface electromyographic (sEMG) data from 20 participants. The protocol included the use of the ULRR along with an interface to execute standardized wrist movements randomly (flexion, extension, radial deviation, and ulnar deviation) at fixed intervals. For the sEMG, representative features were computed, and for the kinematic data, compensatory movements, reaction times, range of movement, and smoothness of movement were estimated. The results showed significant differences in the calculated metrics between YA and OA. The OA group reported 15.5% more compensatory movements and an average of 37 ms increment compared with YA times. Finally, the velocity curves showed more frequency components in OA, which, along with the estimation of the Spectral Arc Length, indicated a smoother movement in the YA group. These outputs can be used to create personalized therapies or to develop a methodology for assessing robotic rehabilitation.

20 March 2026 in Pädi Boletín Científico de Ciencias Básicas e Ingenierías del ICBI
Verified
Journal Article
Open access
PDF file
EPEstefania Suarez Perez
Estefania Suarez Perez
HPHellen Romina Rivero Pineda
Hellen Romina Rivero Pineda
ACAngel Camacho
Angel Camacho
MCManuela Gomez Correa
Manuela Gomez Correa
MBMariana Ballesteros
Mariana Ballesteros
DCDavid Cruz-Ortiz
David Cruz-Ortiz
Este trabajo está enfocado en la generación de una base de datos de señales cinemáticas y de electromiografía superficial (EMG), recolectados mediante un exoesqueleto de miembro superior y un brazalete con sensores de EMG. Los sensores son colocados en la extremidad superior derecha de los participantes. El usuario hace uso del exoesqueleto robótico de rehabilitación y de una interfaz gráfica donde le son mostrados con marcadores movimientos específicos, dichos movimientos son flexión, extensión, desviación cubital y desviación radial de la muñeca. Por medio de esta interfaz se almacenan los datos de los "Encoders" del sistema robótico para obtener la información cinemática. El sistema también cuenta con una segunda interfaz donde son mostradas cuatro gráficas correspondientes a los sensores de EMG colocados en la pulsera, donde a partir de esta, se puede adquirir la información, posprocesarla y almacenarla.