Clare W. Teng

Clare W. Teng

Auto-generated profile, based on publicly available information

Clare W. Teng

Univ Penn, Perelman Sch Med, Philadelphia, PA USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in World Neurosurgery
Verified
Journal Article
Closed access
RBRachel Blue
Rachel Blue
AYAndrew I. Yang
Andrew I. Yang
CZCecilia Zhou
Cecilia Zhou
EREmma De Ravin
Emma De Ravin
CTClare W. Teng
Clare W. Teng
JLJohn Y.K. Lee
John Y.K. Lee

1 July 2022 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
SCSteve S. Cho
Steve S. Cho
CTClare W. Teng
Clare W. Teng
EREmma De Ravin
Emma De Ravin
YSYash B. Singh
Yash B. Singh
JLJohn Y.K. Lee
John Y.K. Lee
Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with nearinfrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed.Methods : Serial dilutions of indocyanine-green (1–2000 μg/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison.Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 μg/L and >31.3 μg/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadoliniumenhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis.Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.