Zsuzsanna Szabó-Krausz

Zsuzsanna Szabó-Krausz

Auto-generated profile, based on publicly available information

Zsuzsanna Szabó-Krausz

Lithosphere Fluid Research Lab, Institute of Geography and Geology, Faculty of Science, Eotvos Lorand University: Eotvos Lorand Tudomanyegyetem, Budapest, Hungary

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2014 in Isotopes in Environmental and Health Studies
Verified
Journal Article
Closed access
ZSZsuzsanna Szabó
Zsuzsanna Szabó
Gyozo JordanGyozo Jordan
Gyozo Jordan
CSCsaba Szabó
Csaba Szabó
ÁHÁkos Horváth
Ákos Horváth
ÓHÓskar Holm
Óskar Holm
ZHZsolt Homoki
Zsolt Homoki
Radon and thoron isotopes are responsible for approximately half of the average annual effective dose to humans. Although the half-life of thoron is short, it can potentially enter indoor air from adobe walls. Adobe was a traditional construction material in the Great Hungarian Plain. Its major raw materials are the alluvial sediments of the area. Here, seasonal radon and thoron activity concentrations were measured in 53 adobe dwellings in 7 settlements by pairs of etched track detectors. The results show that the annual average radon and thoron activity concentrations are elevated in these dwellings and that the proportions with values higher than 300 Bq m−3 are 14–17 and 29–32% for radon and thoron, respectively. The calculated radon inhalation dose is significantly higher than the world average value, exceeding 10 mSv y−1 in 7% of the dwellings of this study. Thoron also can be a significant contributor to the inhalation dose with about 30% in the total inhalation dose. The changes of weather conditions seem to be more relevant in the variation of measurement results than the differences in the local sedimentary geology. Still, the highest values were detected on clay. Through the year, radon follows the average temperature changes and is affected by the ventilation, whereas thoron rather seems to follow the amount of precipitation.

22 June 2014 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
PVPéter Völgyesi
Péter Völgyesi
ZKZoltán Kis
Zoltán Kis
ZSZsuzsanna Szabó
Zsuzsanna Szabó
CSCsaba Szabó
Csaba Szabó

1 February 2020 in Applied Geochemistry
Verified
Journal Article
Closed access
ZSZsuzsanna Szabó-Krausz
Zsuzsanna Szabó-Krausz
NGNóra Edit Gál
Nóra Edit Gál
VGViktória Gável
Viktória Gável
GFGyörgy Falus
György Falus

25 June 2018 in Environmental Earth Sciences
Verified
Journal Article
Closed access
PDF file
ZSZsuzsanna Szabó
Zsuzsanna Szabó
NGNóra Edit Gál
Nóra Edit Gál
ÉKÉva Kun
Éva Kun
TSTeodóra Szőcs
Teodóra Szőcs
GFGyörgy Falus
György Falus

1 September 2017 in Energy Procedia
Verified
Journal Article
Open access
CKCsilla Király
Csilla Király
ZSZsuzsanna Szabó
Zsuzsanna Szabó
ÁSÁgnes Szamosfalvi
Ágnes Szamosfalvi
PKPéter Kónya
Péter Kónya
CSCsaba Szabó
Csaba Szabó
GFGyörgy Falus
György Falus

30 March 2012 in Isotopes in Environmental and Health Studies
Verified
Journal Article
Closed access
HNHedvig Éva Nagy
Hedvig Éva Nagy
ZSZsuzsanna Szabó
Zsuzsanna Szabó
Gyozo JordanGyozo Jordan
Gyozo Jordan
CSCsaba Szabó
Csaba Szabó
ÁHÁkos Horváth
Ákos Horváth
AKAttila Kiss
Attila Kiss
A long-term radon concentration monitoring was carried out in the Pál-völgy cave, Budapest, Hungary, for 1.5 years. Our major goal was to determine the time dependence of the radon concentration in the cave to characterise the air exchange and define the most important environmental parameters that influence the radon concentration inside the cave. The radon concentration in the cave air was measured continuously by an AlphaGuard radon monitor, and meteorological parameters outside the cave were collected simultaneously. The air's radon concentration in the cave varied between 104 and 7776 Bq m−3, the annual average value was 1884±85 Bq m−3. The summer to winter radon concentration ratio was as high as 21.8. The outside air temperature showed the strongest correlation with the radon concentration in the cave, the correlation coefficient (R) was 0.76.