Julia S. Rau

Julia S. Rau

Auto-generated profile, based on publicly available information

Julia S. Rau

Department of Physics, Chalmers University of Technology, SE-412 96, Gothenburg, Sweden

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2024 in Communications Materials
Verified
Journal Article
Open access
PDF file
ADAntje Dollmann
Antje Dollmann
Christian KübelChristian Kübel
Christian Kübel
VTVahid Tavakkoli
Vahid Tavakkoli
Stefan J. EderStefan J. Eder
Stefan J. Eder
MFMichael Feuerbacher
Michael Feuerbacher
CGChristian Greiner
Christian Greiner
Friction and wear of metals are critically influenced by the microstructures of the bodies constituting the tribological contact. Understanding the microstructural evolution taking place over the lifetime of a tribological system therefore is crucial for strategically designing tribological systems with tailored friction and wear properties. Here, we focus on the single-crystalline High-Entropy Alloy CoCrFeMnNi that is prone to form twins at room temperature. Deformation twins feature a pronounced orientation dependence with a tension-compression anisotropy, a distinct strain release in an extended volume and robust onset stresses. This makes deformation twinning an ideal probe to experimentally investigate the complex stress fields occurring in a tribological contact. Our results unambiguously show a grain orientation dependence of twinning under tribological load. It is clearly shown, that twinning cannot be attributed to a single crystal direction parallel to a sample coordinate axes. With deformation twins in the microstructure, stress field models can be validated to make them useable for all different tribological systems.

23 October 2024 in Acta Biomaterialia
Verified
Journal Article
Open access
JRJulia S. Rau
Julia S. Rau
GEGustav Eriksson
Gustav Eriksson
PMPer Malmberg
Per Malmberg
ARAna Laura Puente Reyna
Ana Laura Puente Reyna
JSJens Schwiesau
Jens Schwiesau
Mattias ThuvanderMattias Thuvander
Mattias Thuvander
The surface composition and microstructure of an up to 5 µm thick multilayer on a knee implant were investigated. When the implant was explanted after approximately two years of clinical use due to failure from aseptic loosening, the topmost ZrN layer was found to be oxidized. Interestingly, only the non-articulating area was visibly oxidized (color change). Up until then, the formation and characteristics of the oxide and its influence on the tribological performance remained uncertain. The oxide was thoroughly analyzed using scanning (transmission) electron microscopy (STEM) and atom probe tomography (APT). The articulating and non-articulating areas were compared with an as-fabricated implant, which served as a reference. The results show that a thin oxide was also present on the articulating surface. All measured oxides were thicker than expected from native oxidation. The oxygen content of the majority of the oxide, measured with energy dispersive X-ray spectroscopy (EDS) and APT, was lower than required for the stable ZrO2 form. Underneath the oxide, the ZrN layer remained unaffected, demonstrating the oxide's effective passivating behavior against further oxidation. No cobalt from the substrate was detected within the ZrN layer, proving the multilayer's excellent barrier function against ion release from the base metal. STATEMENT OF SIGNIFICANCE: In our aging society, the use of artificial knee implants is widespread. Implant failure is not only costly, but often connected with pain for the patient and inevitably involves the implantation of a new joint. Hence, understanding the origin of joint failure is of high importance to extend the lifetime of the implant. In this research, we investigate the influence of a surface oxide, formed on an explant which failed after ∼ 2 years, on the multilayer stability. As a novelty, we focus not on the wear of the polyethylene gliding surface but on the formed oxide. The use of high-resolution analysis techniques allowed us to get a glimpse on the ongoing mechanisms at the explants surface.

20 May 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
JRJulia S. Rau
Julia S. Rau
GEGustav Eriksson
Gustav Eriksson
ARAna Laura Puente Reyna
Ana Laura Puente Reyna
JSJens Schwiesau
Jens Schwiesau
MAMartin Andersson
Martin Andersson
Mattias ThuvanderMattias Thuvander
Mattias Thuvander
Before knee implants are used in clinical applications, in-vitro wear simulation is essential for predicting their reliability and longevity. This study investigated the representativeness of in-vitro wear simulation concerning oxide formation on a ZrN multilayer-coated knee implant. Four different locations on one in-vitro tested sample were analyzed using scanning (transmission) electron microscopy (SEM/TEM). The sample was subjected to 5 million gait cycles according to ISO 14242-1:2002 in newborn calf serum at body temperature, equivalent to ∼ 3-5 years in-vivo. The formed surface oxides were compared with a previously investigated as-fabricated femoral component and an 'in-vivo' implant explanted after approximately two years due to early aseptic loosening. The results showed the presence of an oxide on all investigated surfaces with varying thicknesses (15-280 nm). Hence, all oxides were thicker than what would be expected from native oxidation of ZrN. Oxide composition, thickness and microstructure were comparable between in-vitro and in-vivo samples, except one outlier on the in-vitro sample (280 nm thick oxide). However, the distribution of the colored areas was not comparable: the in-vivo sample exhibited a non-articulating area completely purplish colored (art. area golden), whereas colored areas on the in-vitro sample were distributed inhomogenously. Differences in loading conditions, presence of embedded particles, exposure duration and fluids could explain these variations.

23 November 2022 in arXiv
Verified
Preprint
Open access
PDF file
ADAntje Dollmann
Antje Dollmann
JRJulia Rau
Julia Rau
BBBeatrix Bieber
Beatrix Bieber
LMLakshmi Mantha
Lakshmi Mantha
Christian KübelChristian Kübel
Christian Kübel
CGChristian Greiner
Christian Greiner
Microstructural evolution under tribological load is known to change the friction and wear response of the entire tribological system. It is however not yet fully understood, how these changes take place on an elementary, mechanistic level. Revealing the temporal sequence of deformation mechanisms under a tribological load by experiments is scarce. The discrete strain release in the case of deformation twinning allows the identification of their temporal sequence. Therefore, a medium stacking fault energy material, namely CoCrNi, was investigated due to the significant contribution of deformation twinning to the overall deformation at room temperature. The investigated grain showed three activated twin systems. The evolution sequence of these is discussed critically based on several twin intersection mechanisms. The experimental analysis decodes the temporal sequence of the active twinning systems of highest resolved shear stresses for the first time. This approach gives experimental indications for the stress field under a tribological load.