Peng Sun

Peng Sun

Auto-generated profile, based on publicly available information

Peng Sun

State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, 47913 Chongqing China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
RLRuikuo Liu
Ruikuo Liu
JYJun Yao
Jun Yao
XWXuewei Wang
Xuewei Wang
PSPeng Sun
Peng Sun
JPJinxin Pei
Jinxin Pei
JHJiabing Hu
Jiabing Hu
With the increasing penetration of the wind power, the stability issues of the weak AC grid-connected doubly fed induction generator (DFIG)-based wind turbines during low voltage ride through (LVRT) cannot be neglected. In order to explore the instability mechanism of DFIG system during weak grid fault, the small signal state space model is established in this paper. The results of the modal analysis show that the dominant unstable poles are mainly impacted by the phase locked loop (PLL), rotor current control loop (RCCL) and terminal voltage during the fault, where the PLL is the dominant factor. Furthermore, the impact of each factors on the system dynamic stability are comprehensively evaluated, which indicates that the controller bandwidth under normal grid condition is no longer apply to the fault condition due to the interaction between the controller and grid. Then, the optimal current proportion which can significantly improve the system stability is deduced. Finally, based on the analysis, this paper proposes the improved LVRT control schemes from two aspects of either injecting active current or decreasing PLL bandwidth to enhance the system small signal stability. The effectiveness of the proposed LVRT control strategies is validated by the simulation and experiments.

31 July 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JPJinxin Pei
Jinxin Pei
JYJun Yao
Jun Yao
RLRuikuo Liu
Ruikuo Liu
DZDeyin Zeng
Deyin Zeng
PSPeng Sun
Peng Sun
YLYuan Liu
Yuan Liu
The voltage-frequency coupled transient stability and risk assessment issues of weak grid-connected large-scale renewable energy plants (REPs) during low voltage ride-through (LVRT) have received little attention to date. The shape and mechanism of voltage-frequency coupled transient instability during LVRT was investigated in detail by the voltage-vector-triangle graphic (VTG) method utilized in this study, which avoids complex mathematical calculations. In addition, the margin of the transmission line's voltage angle (MTVA) was defined in this paper and was then used to quantitatively assess the transient instability risk of the large-scale REPs during LVRT. Furthermore, the expressions of the MTVA were deduced under different conditions and the major influencing factors which resulted in instability risk were determined correspondingly. On this basis, the transient instability risk assessment standard of the large-scale REPs is built and the instability risk minimized scheduling strategy is proposed in this paper, which does not change the internal control structure and parameters of the REPs during LVRT. Finally, both the correctness of the VTG method and the risk assessment standard, and the effectiveness of the scheduling strategy proposed in this paper are validated by experiments and simulations.

8 June 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TZTian Zhang
Tian Zhang
JYJun Yao
Jun Yao
PSPeng Sun
Peng Sun
JPJinxin Pei
Jinxin Pei
HZHailin Zhang
Hailin Zhang
YZYang Zhao
Yang Zhao
The commutation failure fault usually occurs in the Line Commutated Converter (LCC)-based High Voltage Direct Current (HVDC) transmission system. When commutation failure fault occurs, the voltage of sending Alternate Current (AC) system changes rapidly and the connected Doubly Fed Induction Generator (DFIG)-based wind turbine may be tripped. Thus, the Fault Ride Through (FRT) control strategy of DFIG should be investigated for enhancing the stability of the sending AC system. However, the voltage of the sending AC system during commutation failure isn't changed in rectangular in shape, besides, the voltage presents the “first reduce then rise” characteristic, which is not considered in the existing FRT control strategies. In order to realize the continuous FRT of DFIG during commutation failure, the stator flux and Electromotive Force (EMF) when the stator voltage changes continuously have been analyzed for the first time in this paper. Furthermore, based on the analysis results, an improved continuous FRT control strategy is proposed. The simulation and experiment results validate the effectiveness of the proposed method. The proposed control strategy is not only suitable for the commutation failure condition, but also for the scenario with continuous voltage variation during grid fault, which indicates that the proposed method is general.