1 August 2000 in Química Nova
The need for new materials to substitute injured or damaged parts of the human body has led scientists of different areas to the investigation of bioceramics since the 70's, when other materials in use started to show implantation problems. Bioceramics show some advantages like being the material that best mimics the bone tissue but also, present low mechanical strength due to its ceramic nature. This paper presents a general view about the topic.
12 June 2002 in Journal of Biomedical Materials Research
1 January 1996 in Analytical Communications
Hydroxyapatite, prepared by precipitation from a calcium hydroxide suspension with phosphoric acid at 60 °C and a pH of 9, was used to develop a potentiometric sensor for phosphate. The electrodes were made in two ways: firstly, by mixing hydroxyapatite powder with an epoxy polymer and graphite; and secondly, by sealing porous hydroxyapatite sticks to the extremity of a glass tube. The first sensor showed a very small linear range of response (6.0 × 10–5 to 2.0 × 10–4 mol l–1) to log [phosphate] at pH = 5.0, with a slope of 55 mV decade–1 of phosphate concentration and a detection limit of 4.0 × 10–5 mol l–1. The second showed a higher linear response range from 5.0 × 10–5 up to 5.0 × 10–2 mol l–1, with a slope of 33 mV decade–1 and a detection limit of 2.5 × 10–5 mol l–1, under the same conditions. The response time was about 25 s in the first case and 40 s in the second. The effects of interfering ions were investigated and the Kpot values for Cl–, NO3 –, SO4 2–, ClO4 –, acetate and citrate were determined, showing only a small interference with the electrode response. The powder electrode is not stable but the stick has good stability.
1 April 2013 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
MFMaria Tereza Cortez Fernandes
Maria Tereza Cortez Fernandes
RGRenata Batista Rivero Garcia
Renata Batista Rivero Garcia
CLCarlos Alberto Paula Leite
Carlos Alberto Paula Leite
1 March 2007 in Journal of Craniofacial Surgery
CBCelso Aparecido Bertran
Autogenous bone grafts have frequently been used in the treatment of bone defects; however, this procedure can cause clinical complications after surgery. Besides, the amount of available bone is sometimes insufficient. Therefore, synthetic biomaterials have been researched as an alternative to autogenous bone graft implants. The objective of this study was to evaluate the repair of bone defects treated with compact autogenous bone graft or porous calcium phosphate ceramics. Three defects 3 mm in diameter were produced in the skull of 21 rats. One the defects was produced in the frontal bone, which remained empty, while the others were produced in the right and left parietal bones, which were filled respectively with ceramics and autogenous bone graft. The animals were sacrificed 1, 2, 4, and 24 weeks after surgery and analyzed by light microscopy and radiography. In the twenty-fourth week, the defects filled with autogenous bone graft and ceramics had similar volumes of newly formed bone tissue. The ceramics offered favorable conditions to bone tissue growth. Thus, we concluded that the calcium phosphate ceramic implant proved to be effective in repairing defects produced in the skull of rats.
1 June 2021 in Surfaces and Interfaces