Andrei Matlashov

Andrei Matlashov

Auto-generated profile, based on publicly available information

Andrei Matlashov

Center for Axion and Precision Physics Research (CAPP), IBS, Daejeon 34051, Republic of Korea

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2021 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
OKOhjoon Kwon
Ohjoon Kwon
DLDoyu Lee
Doyu Lee
WCWoohyun Chung
Woohyun Chung
DADanho Ahn
Danho Ahn
HBHeeSu Byun
HeeSu Byun
YSYannis K. Semertzidis
Yannis K. Semertzidis
The Center for Axion and Precision Physics Research at the Institute for Basic Science is searching for axion dark matter using ultralow temperature microwave resonators. We report the exclusion of the axion mass range 10.7126–10.7186  μeV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16–11.37  μeV with about 9 times larger coupling at 90% confidence level. This is the first axion search result in these ranges. It is also the first with a resonator physical temperature of less than 40 mK.

28 February 2023 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
JKJinsu Kim
Jinsu Kim
OKOhjoon Kwon
Ohjoon Kwon
ÇKÇağlar Kutlu
Çağlar Kutlu
WCWoohyun Chung
Woohyun Chung
AMAndrei Matlashov
Andrei Matlashov
YSYannis K. Semertzidis
Yannis K. Semertzidis
We report the results of an axion dark matter search over an axion mass range of 9.39–9.51  μeV. A flux-driven Josephson parametric amplifier (JPA) was added to the cryogenic receiver chain. A system noise temperature of as low as 200 mK was achieved, which is the lowest recorded noise among published axion cavity experiments with phase-insensitive JPA operation. In addition, we developed a two-stage scanning method which boosted the scan speed by 26%. As a result, a range of two-photon coupling in a plausible model for the QCD axion was excluded with an order of magnitude higher in sensitivity than existing limits.

1 April 2018 in Cryogenics
Verified
Journal Article
Closed access
AMAndrei Matlashov
Andrei Matlashov
MSMatthias Schmelz
Matthias Schmelz
VZVyacheslav Zakosarenko
Vyacheslav Zakosarenko
RSRonny Stolz
Ronny Stolz
YSYannis K. Semertzidis
Yannis K. Semertzidis

22 November 2016 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
WAW. H. Anderson
W. H. Anderson
EFE. R. Flynn
E. R. Flynn
TKT. Karaulanov
T. Karaulanov
AMA. N. Matlashov
A. N. Matlashov
CNC. Nettles
C. Nettles
WRW. Radigan
W. Radigan
Superparamagnetic relaxometry (SPMR) is a new technology used for detection and localization of cells tagged with super-paramagnetic nanoparticles. SPMR is one of the most promising methods for early cancer diagnosis with the potential for submillimeter size tumor resolution. SQUID-based gradiometers are very suitable for such sensitive measurements. Presently, most commonly used SPMR instruments consist of axial wire-wound gradiometers connected to SQUID-sensors placed inside tight superconducting shields. This configuration avoids flux trapping by the Josephson junctions during magnetization. A thin-film planar gradiometer integrated with a SQUID on a single chip traps flux, if it picks up even small portion of a magnetizing field. Thermal cycling is very slow, therefore it is not practical. Special measures must be applied such as newly developed methods of SQUIDs ac de-fluxing. Planar thin-film gradiometers have advantages over axial wire-wound gradiometers because of their much higher balance level, higher reliability, and reproducibility in production, and significant simplification of multichannel systems design. In this paper, we compare experimental results received using axial wire-wound and planar thin-film gradiometers. This comparison is based on SPMR measurements conducted using the seven-channel axial second-order gradiometer system and two systems with different geometries of the thin-film first-order planar gradiometer arrays. We discuss advantages and drawbacks of the two types of gradiometers.