Quantitative susceptibility mapping (QSM) is a promising non-invasive method for obtaining information relating to oxygen metabolism. However, the optimal acquisition sequence and QSM reconstruction method for reliable venous susceptibility measurements are unknown. Full flow compensation is generally recommended to correct for the influence of venous blood flow, although the effect of flow compensation on the accuracy of venous susceptibility values has not been systematically evaluated. In this study, we investigated the effect of different acquisition sequences, including different flow compensation schemes, and different QSM reconstruction methods on venous susceptibilities. Ten healthy subjects were scanned with five or six distinct QSM sequence designs using monopolar readout gradients and different flow compensation schemes. All data sets were processed using six different QSM pipelines and venous blood susceptibility was evaluated in whole-brain segmentations of the venous vasculature and single veins. The quality of vein segmentations and the accuracy of venous susceptibility values were analyzed and compared between all combinations of sequences and reconstruction methods. The influence of the QSM reconstruction method on average venous susceptibility values was found to be 2.7-11.6 times greater than the influence of the acquisition sequence, including flow compensation. The majority of the investigated QSM reconstruction methods tended to underestimate venous susceptibility values in the vein segmentations that were obtained. In summary, we found that multi-echo gradient-echo acquisition sequences without full flow compensation yielded venous susceptibility values comparable to sequences with full flow compensation. However, the QSM reconstruction method had a great influence on susceptibility values and thus needs to be selected carefully for accurate venous QSM.
The myelin concentration and the degree of myelination of nerve fibers can provide valuable information on the integrity of human brain tissue. Magnetic resonance imaging (MRI) of myelin-sensitive parameters can help to non-invasively evaluate demyelinating diseases such as multiple sclerosis (MS). Several different myelin-sensitive MRI methods have been proposed to determine measures of the degree of myelination, in particular the g-ratio. However, variability in underlying physical principles and different biological models influence measured myelin concentrations, and consequently g-ratio values. We therefore investigated similarities and differences between five different myelin-sensitive MRI measures and their effects on g-ratio mapping in the brains of both MS patients and healthy volunteers.
Multi-parameter mapping (MPM) magnetic resonance imaging (MRI) provides quantitative estimates of the longitudinal and effective transverse relaxation rates R1 and R2*, proton density (PD), and magnetization transfer saturation (MTsat). Thereby, MPM enables better comparability across sites and time than conventional weighted MRI. However, for MPM, several contrasts must be acquired, resulting in prolonged measurement durations and thus preventing MPM's application in clinical routines. State-of-the-art imaging acceleration techniques such as Compressed SENSE (CS), a combination of compressed sensing and sensitivity encoding, can be used to reduce the scan time of MPM. However, the accuracy and precision of the resulting quantitative parameter maps have not been systematically evaluated. In this study, we therefore investigated the effect of CS acceleration on the fidelity and reproducibility of MPM acquisitions. In five healthy volunteers and in a phantom, we compared MPM metrics acquired without imaging acceleration, with the standard acceleration (SENSE factor 2.5), and with Compressed SENSE with acceleration factors 4 and 6 using a 32-channel head coil. We evaluated the reproducibility and repeatability of accelerated MPM using data from three scan sessions in gray and white matter volumes-of-interest (VOIs). Accelerated MPM provided precise and accurate quantitative parameter maps. For most parameters, the results of the CS-accelerated protocols correlated more strongly with the non-accelerated protocol than the standard SENSE-accelerated protocols. Furthermore, for most VOIs and contrasts, coefficients of variation were lower when calculated from data acquired with different imaging accelerations within a single scan session than from data acquired in different scan sessions with the same acceleration method. These results suggest that MPM with Compressed SENSE acceleration factors up to at least 6 yields reproducible quantitative parameter maps that are highly comparable to those acquired without imaging acceleration. Compressed SENSE can thus be used to considerably reduce the scan duration of R1, R2*, PD, and MTsat mapping, and is highly promising for clinical applications of MPM.
Quantitative susceptibility mapping (QSM) is a promising non-invasive method for obtaining information relating to the oxygen metabolism. However, the optimal acquisition sequence and QSM reconstruction method for reliable venous susceptibility measurements are unknown. Full flow compensation is generally recommended to correct for the influence of venous blood flow, although the effect of flow compensation on the accuracy of venous susceptibility values has not been systematically evaluated. In this study, we investigated the effect of different acquisition sequences, including different flow compensation schemes, and different QSM reconstruction methods on venous susceptibilities. Ten healthy subjects were scanned with five or six distinct QSM sequence designs implementing different flow compensation schemes. All data sets were processed using six different QSM pipelines and venous blood susceptibility was evaluated in whole-brain segmentations of the venous vasculature and single veins. The quality of vein segmentations and the accuracy of venous susceptibility values were analyzed and compared between all combinations of sequences and QSM methods. The influence of the QSM method on average venous susceptibility values was found to be 2.7 - 11.6 times greater than the influence of the acquisition sequence, including flow compensation. The majority of the investigated QSM reconstruction methods tended to underestimate venous susceptibility values in the vein segmentations that were obtained. Using multi-echo gradient-echo acquisitions with monopolar readout gradients, we found that sequences without full flow compensation yielded venous susceptibility values comparable to sequences with full flow compensation. However, the QSM method had a great influence on susceptibility values and thus needs to be considered carefully for accurate venous QSM.
Conventional T1-weighted (T1w) magnetic resonance imaging (MRI) is commonly used in multiple sclerosis (MS) morphometry and volumetry research. However, arbitrary intensity scales preclude interpretation of signal values across patients, sites, and time. This requires quantitative MRI techniques, which are not always available. This study assessed T1w image intensity scaling methods, relying on extracerebral reference regions, for quantitative analysis of brain MRI in MS. In total, 701 people with a diagnosis of radiologically isolated syndrome, clinically isolated syndrome, or MS were included. Four intensity scaling strategies were applied: 1) MRI signal modeling, 2) linear scaling with reference regions, 3) z-score standardization, and 4) none (only bias field correction). Methods were evaluated using variance analysis, R1 map comparison, and normal-appearing white matter (NAWM) intensity group comparison, using mean and coefficient of variation (CoV), between low (≤3) and high (>3) expanded disability status scale (EDSS) scores. Statistical analysis was conducted using Pearson's r, two-sided Welch two-sample t-test, ANCOVA, and Cohen's d. Linear scaling with temporal fatty tissue achieved the most consistent variance reduction and strong correlation with R1 maps (r = 0.84). R1 values in NAWM were significantly lower in people with high compared to low EDSS scores (d = -0.351). Similarly, group differences in mean NAWM intensity of fat-scaled images were significant (d = -0.252). The largest group differences were found in NAWM CoV in bias field-corrected T1w images (d = 0.818). Linear scaling with fatty tissue most accurately reproduced the results obtained with R1 maps. Changes in MS NAWM appear to increase intensity variability detectable in conventional T1w images.
Background and ObjectivesParamagnetic rim lesions (PRLs) have been established as a radiologic surrogate for chronic active inflammation in multiple sclerosis (MS). Although associations between PR...