Marc Kouwenhoven

Marc Kouwenhoven

Auto-generated profile, based on publicly available information

Marc Kouwenhoven

Department of MR R&D Clinical Science, Philips, Best, The Netherlands

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 1998 in Electronics Letters
Verified
Journal Article
Closed access
MKM.H.L. Kouwenhoven
M.H.L. Kouwenhoven
JMJ. Mulder
J. Mulder
ARA.H.M. van Roermund
A.H.M. van Roermund
Current noise analysis techniques for translinear and other companding filters are unsuitable for circuits that contain intentional dynamic nonlinearities. The authors present a method for treating dynamic nonlinearities in a straightforward manner using stochastic differential equations.

8 November 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
GKGuruprasad Krishnamoorthy
Guruprasad Krishnamoorthy
JTJoao Tourais
Joao Tourais
JSJouke Smink
Jouke Smink
MBMarcel Breeuwer
Marcel Breeuwer
MKMarc Kouwenhoven
Marc Kouwenhoven
Purpose: To develop a free‐breathing (FB) 2D radial balanced steady‐state free precession cine cardiac MRI method with 100% respiratory gating efficiency using respiratory auto‐calibrated motion correction (RAMCO) based on a motion‐sensing camera.Methods: The signal from a respiratory motion‐sensing camera was recorded during a FB retrospectively electrocardiogram triggered 2D radial balanced steady‐state free precession acquisition using pseudo–tiny‐golden‐angle ordering. With RAMCO, for each acquisition the respiratory signal was retrospectively auto‐calibrated by applying different linear translations, using the resulting in‐plane image sharpness as a criterium. The auto‐calibration determines the optimal magnitude of the linear translations for each of the in‐plane directions to minimize motion blurring caused by bulk respiratory motion. Additionally, motion‐weighted density compensation was applied during radial gridding to minimize through‐plane and non‐bulk motion blurring. Left ventricular functional parameters and sharpness scores of FB radial cine were compared with and without RAMCO, and additionally with conventional breath‐hold Cartesian cine on 9 volunteers.Results: FB radial cine with RAMCO had similar sharpness scores as conventional breath‐hold Cartesian cine and the left ventricular functional parameters agreed. For FB radial cine, RAMCO reduced respiratory motion artifacts with a statistically significant difference in sharpness scores (P < 0.05) compared to reconstructions without motion correction.Conclusion: 2D radial cine imaging with RAMCO allows evaluation of left ventricular functional parameters in FB with 100% respiratory efficiency. It eliminates the need for breath‐holds, which is especially valuable for patients with no or impaired breath‐holding capacity. Validation of the proposed method on patients is warranted.

15 October 2025 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
JTJoao Tourais
Joao Tourais
GKGuruprasad Krishnamoorthy
Guruprasad Krishnamoorthy
JSJouke Smink
Jouke Smink
MBMarcel Breeuwer
Marcel Breeuwer
MKMarc Kouwenhoven
Marc Kouwenhoven
Objective: To develop a non-iterative method for applying elliptical field-of-view (FOV) to radial imaging and evaluate it for Stack-Of-Stars (SOS) with variable radial density in the $${k}_{z}$$ k z direction. Materials and methods: New analytic expressions were derived to compute the radial profile angles for an elliptical FOV with and without golden angle sampling. With a major-to-minor-axis FOV ratio of 1:0.5, anisotropic FOV and variable density SOS were evaluated, using point spread function analysis, phantom imaging, and in vivo pelvic imaging. Results: Compared with conventional SOS, elliptical density in $${k}_{z}$$ k z reduced scan time by 20%, while maintaining similar levels of radial aliasing artifacts. Anisotropic FOV reduced scan time by 31%, resulting in similar levels of radial aliasing artifacts at low undersampling for objects with matching in-plane anisotropy. Combining both techniques resulted in a 45% scan time reduction. Alternatively, when compared to conventional SOS using identical scan time, variable density and anisotropic FOV both displayed a lower level of radial aliasing artifacts, although for anisotropic FOV this effect was less pronounced at higher undersampling. Discussion: Variable density and anisotropic FOV can reduce scan time and/or reduce aliasing artifacts for SOS. The new analytical expressions for elliptical FOV will facilitate future studies on anisotropic FOV radial imaging.