Stefania Montemezzi

Stefania Montemezzi

Auto-generated profile, based on publicly available information

Stefania Montemezzi

Radiology Unit, Department of Pathology and Diagnostics, University Hospital of Verona, Piazzale Aristide Stefani, 1, 37126 Verona, Italy

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in European Journal of Radiology
Verified
Journal Article
Closed access
SMStefania Montemezzi
Stefania Montemezzi
LCLucia Camera
Lucia Camera
MGMaria Grazia Giri
Maria Grazia Giri
APAlice Pozzetto
Alice Pozzetto
ACAnna Caliò
Anna Caliò
CCCarlo Cavedon
Carlo Cavedon

1 November 2021 in Neurology Neuroimmunology & Neuroinflammation
Verified
Journal Article
Open access
PDF file
DMDamiano Marastoni
Damiano Marastoni
RMRoberta Magliozzi
Roberta Magliozzi
ABAnna Bolzan
Anna Bolzan
APAnna Isabella Pisani
Anna Isabella Pisani
SRStefania Rossi
Stefania Rossi
Massimiliano CalabreseMassimiliano Calabrese
Massimiliano Calabrese
Background and Objectives To evaluate the extent of intrathecal inflammation in patients with primary progressive MS (PPMS) at the time of diagnosis and to define markers and a specific inflammatory profile capable of distinguishing progressive from relapsing-remitting multiple sclerosis (RRMS). Methods Levels of 34 pro- and anti-inflammatory cytokines and chemokines in the CSF were evaluated at the diagnosis in 16 patients with PPMS and 80 with RRMS. All patients underwent clinical evaluation, including Expanded Disability Status Scale assessment and a 3T brain MRI to detect white matter and cortical lesion number and volume and global and regional cortical thickness. Results Higher levels of CXCL12 (odds ratio [OR] = 3.97, 95% CI [1.34–11.7]) and the monocyte-related osteopontin (OR = 2.24, 95% CI [1.01–4.99]) were detected in patients with PPMS, whereas levels of interleukin-10 (IL10) (OR = 0.28, 95% CI [0.09–0.96]) were significantly increased in those with RRMS. High CXCL12 levels were detected in patients with increased gray matter lesion number and volume (p = 0.001, r = 0.832 and r = 0.821, respectively). Pathway analysis confirmed the chronic inflammatory processes occurring in PPMS. Conclusions At the time of diagnosis, a specific CSF protein profile can recognize the presence of early intrathecal inflammatory processes, possibly stratifying PPMS with respect to RRMS. Elevated CSF levels of CXCL12 and osteopontin suggested a key role of brain innate immunity and glia activity in MS. These molecules could represent useful candidate markers of MS progression, with implications for the pathogenesis and treatment of progressive MS. Classification of Evidence This study provides Class III evidence that CXCL12 and monocyte-related osteopontin may be correlated with PPMS, and IL-10 may be related to RRMS. It is may be correlated due to Bonferroni correction negating the statistical correlations found in the study.

1 January 2019 in European Journal of Radiology Open
Verified
Journal Article
Open access
MRM. Ricci
M. Ricci
MBM. Boldini
M. Boldini
EBE. Bonfante
E. Bonfante
ESE. Sambugaro
E. Sambugaro
EVE. Vecchini
E. Vecchini
SMS. Montemezzi
S. Montemezzi
CBCT is an imaging technique consisting of X-ray computed tomography, in which the x-rays are divergent, forming a cone. During 2015, a new model of CBCT, New Tom 5G XL (Verona), was used in the Radiology Department of The University of Verona, in collaboration with the Orthopaedics Department. Our study was carried out from October 2015 to October 2016 (198 patients). We compared CBCT with standard x-ray in the diagnosis of foot and anke fractures (and Lisfranc lesions), tibial plateau fractures, wrist and scaphoid fractures, elbow fractures. All patients were analyzed, of which 143 were positive or had documented bone lesions, while 55 were with no fractures seen. Of the 55 negative patients, 19 were considered positive at Standard RX, thus in 34.5% of cases the X-ray Standard examination overestimated the disease (false positive cases). Similarly, of the 143 positive patients, 21 were negative at RX, resulting in 14.6% of false negatives. We can say that if compared to standard X-ray, CBCT has higher sensitivity and specificity in the proper identification and typing of these kind of lesions, with low exposition dose if compared to MDCT. The most common rx-unrecognized fractures were in small bones of carpus and tarsus.

18 March 2022 in La radiologia medica
Verified
Journal Article
Open access
PDF file
ENEmanuele Neri
Emanuele Neri
VGVincenza Granata
Vincenza Granata
SMStefania Montemezzi
Stefania Montemezzi
PBPaolo Belli
Paolo Belli
DBDaniela Bernardi
Daniela Bernardi
ROBERTO GRASSIROBERTO GRASSI
ROBERTO GRASSI
Background: Radiology is an essential tool in the management of a patient. The aim of this manuscript was to build structured report (SR) Mammography based in Breast Cancer. Methods: A working team of 16 experts (group A) was composed to create a SR for Mammography Breast Cancer. A further working group of 4 experts (group B), blinded to the activities of the group A, was composed to assess the quality and clinical usefulness of the SR final draft. Modified Delphi process was used to assess level of agreement for all report sections. Cronbach’s alpha (Cα) correlation coefficient was used to assess internal consistency and to measure quality analysis according to the average inter-item correlation. Results: The final SR version was built by including n = 2 items in Personal Data, n = 4 items in Setting, n = 2 items in Comparison with previous breast examination, n = 19 items in Anamnesis and clinical context; n = 10 items in Technique; n = 1 item in Radiation dose; n = 5 items Parenchymal pattern; n = 28 items in Description of the finding; n = 12 items in Diagnostic categories and Report and n = 1 item in Conclusions. The overall mean score of the experts and the sum of score for structured report were 4.9 and 807 in the second round. The Cronbach’s alpha (Cα) correlation coefficient was 0.82 in the second round. About the quality evaluation, the overall mean score of the experts was 3.3. The Cronbach’s alpha (Cα) correlation coefficient was 0.90. Conclusions: Structured reporting improves the quality, clarity and reproducibility of reports across departments, cities, countries and internationally and will assist patient management and improve breast health care and facilitate research.

27 May 2021 in La radiologia medica
Verified
Journal Article
Open access
PDF file
NCNicolò Cardobi
Nicolò Cardobi
Giulio BenettiGiulio Benetti
Giulio Benetti
GCGiuseppe Cardano
Giuseppe Cardano
CACinzia Arena
Cinzia Arena
CMClaudio Micheletto
Claudio Micheletto
SMStefania Montemezzi
Stefania Montemezzi
Purpose: To classify COVID-19, COVID-19-like and non-COVID-19 interstitial pneumonia using lung CT radiomic features. Material and Methods: CT data of 115 patients with respiratory symptoms suspected for COVID-19 disease were retrospectively analyzed. Based on the results of nasopharyngeal swab, patients were divided into two main groups, COVID-19 positive (C +) and COVID-19 negative (C−), respectively. C− patients, however, presented with interstitial lung involvement. A subgroup of C−, COVID-19-like (CL), were considered as highly suggestive of COVID pneumonia at CT. Radiomic features were extracted from the whole lungs. A dual machine learning (ML) model approach was used. The first one excluded CL patients from the training set, eventually included on the test set. The second model included the CL patients also in the training set. Results: The first model classified C + and C− pneumonias with AUC of 0.83. CL median response (0.80) was more similar to C + (0.92) compared to C− (0.17). Radiomic footprints of CL were similar to the C + ones (possibly false negative swab test). The second model, however, merging C + with CL patients in the training set, showed a slight decrease in classification performance (AUC = 0.81). Conclusion: Whole lung ML models based on radiomics can classify C + and C− interstitial pneumonia. This may help in the correct management of patients with clinical and radiological stigmata of COVID-19, however presenting with a negative swab test. CL pneumonia was similar to C + pneumonia, albeit with slightly different radiomic footprints.

1 January 2021 in Radiology
Verified
Journal Article
Closed access
FCFrancesca Caumo
Francesca Caumo
SMStefania Montemezzi
Stefania Montemezzi
GRGiovanna Romanucci
Giovanna Romanucci
SBSilvia Brunelli
Silvia Brunelli
PBPaola Bricolo
Paola Bricolo
GGGisella Gennaro
Gisella Gennaro
Digital breast tomosynthesis at first round and at repeat screening depicted a higher proportion of stage I cancers than screening with digital mammography. Background Few results are available about subsequent outcomes after screening with digital breast tomosynthesis (DBT). Purpose To compare the diagnostic accuracy of a screening round with DBT plus...