Mrigendra Amatya

Mrigendra Amatya

Auto-generated profile, based on publicly available information

Mrigendra Amatya

Department of Physiology, Nepal Medical College, Gokarneswor-8, Kathmandu

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2019 in Nepal Medical College Journal
Verified
Journal Article
Open access
PDF file
MAMrigendra Amatya
Mrigendra Amatya
DPD.B. Pun
D.B. Pun
The spirometric measurements are very sensitive, accurate and reliable parameters, which have diagnostic as well as prognostic values. We aimed to find the reliability of two simple measurements, namely chest expansion and voluntary breath holding, which are often suggested as tools for screening and monitoring of respiratory diseases. A cross-sectional descriptive study was conducted on students of Nepal Medical College. Measurements of spirometry (forced vital capacity, FVC in liter; forced expiratory volume in first second, FEV1 in liter; and peak expiratory flow rate, PEF in liter persecond), cirtometry (average of maximum chest expansion, CE in centimeter), and breath-holding time (maximum voluntary apnea at end-inspiration, MVAIT and maximum voluntary apnea at end expiration, MVAET in second) were performed. Degrees of correlation (Pearson’s r) were determined between different parameters; setting level of significance at 95%. Total 308 students (M=164, 53.25%;F=144, 46.75%) participated. Owing to very highly significant differences between males and females, gender-separate correlations were determined. In males, CE correlation was very highly significant (p=0.000) with FVC and FEV1 but not with PEF. MVAET correlated significantly with FVC, FEV1 and PEF; MVAIT correlation was not significant with any parameters. In females, CE correlation was significant with FVC and FEV1 but not with PEF; MVAET and MVAIT correlations were not significant with any of the parameters. In conclusion, the correlation of CE with different spirometric parameters is significant but not very strong (0.3<r<0.5). Also, gender differences exist. Therefore, using CE and breath-holding time may not be appropriate to assess respiratory ventilatory function.

31 March 2020 in Journal of College of Medical Sciences-Nepal
Verified
Journal Article
Open access
ONOjashwi Nepal
Ojashwi Nepal
STSamjhana Thapa
Samjhana Thapa
RKRoshan Kasti
Roshan Kasti
RJReena Kumari Jha
Reena Kumari Jha
MAMrigendra Amatya
Mrigendra Amatya
Background: Public transport drivers are constantly being exposed to stimuli and are at risk of disorder of peripheral nervous system which can be further complicated by comorbidities. Thus, we wanted to examine intactness of tactile discriminatory ability in healthy drivers by comparing it to healthy samples of non-driving population. Since two point discrimination (TPD) test is frequently used for neurological assessment of tactile stimulation we determined and compared various locations in hands of two populations. Methods: Participants were asked to answer whether they feel one point or two points touch by blunted end of simple compass divider in their hand. The minimum distance between the points at which the participants could answer correctly was noted as two point discrimination value. Results: Drivers had TPD range of 2-4mm with mean 2.53±0.62 and, 1-4mm with mean 2.6±0.72 at middle finger of right and left hand respectively. Following t-test between drivers versus students, significant difference in the mean TPD value in the proximal palm supplied by median nerve (p=0.016) and proximal palm corresponding to ulnar nerve (p=0.032) on the right hand was found. On the left hand, significant difference in the mean TPD value is found in the proximal palm corresponding to median nerve (p=0.008) and ulnar nerve (p=0.043) respectively. Conclusion: Healthy public transport drivers have less tactile discriminating prowess at proximal palmar surface of hand. Examined distal phalanges and distal palm showed no significant difference in mean of TPD values for healthy drivers versus students.

13 July 2020 in Nepal Medical College Journal
Verified
Journal Article
Open access
PDF file
MAMrigendra Amatya
Mrigendra Amatya
Adverse effects (AE) like vasovagal reactions (presyncope and syncope) have negative impact on old as well as new blood donors. Various methods have been suggested to prevent or attenuate AE in blood donors. This study assessed the effectiveness of prehydration with different fluids or applied muscle tension (AMT) during blood donation in preventing or attenuating AE. Consenting and eligible voluntary blood donors (n=448) were randomly allocated to Control (n=115), prehydration with 500 mL plain water (PW, n=97), prehydration with oral rehydration solution (ORS, n=71), prehydration with 400 mL fruit juice (FJ, n=74), or leg muscle tensing during blood removal (AMT, n=91) groups. Donors’ hemodynamic responses to blood donation were assessed by comparing blood pressures (systolic–SBP and diastolic–DBP) and heart rate (HR) recorded before blood removal to values midway during, and at 0 min, 5 min, 10 min and 15 min after blood removal. Presyncope and syncope were defined by BP and HR changes. Subjective AE were also recorded. Overall, 35 donors (7.8%) suffered AE with highest rates in PW (13.4%) and ORS (11.3%) groups and lowest in Control (3.5%) although group differences were not significant (p>0.05, Chi square). Blood removal was associated with significant falls in SBP and DBP (mean falls by 6.63 and 3.35 mmHg, respectively; p0.05). Hemodynamic responses showed significant differences between groups (p

27 June 2020 in Journal of Kathmandu Medical College
Verified
Journal Article
Closed access
PDF file
MAMrigendra Amatya
Mrigendra Amatya
BKBibek Khanal
Bibek Khanal
Background: Occupational drivers are exposed to various stressors such as ergonomic restriction, whole body vibration, vehicle exhaust and dust exposure. Drivers are reported to have higher rates of morbidities, especially of the musculoskeletal and peripheral nervous systems. Reports on drivers’ nerve functions by specific electrodiagnostic methods are lacking. Objectives: To compare electrophysiologic parameters of median and ulnar nerves in drivers with other population. Methodology: In a cross-sectional comparative study, nerve conduction study was performed in median and ulnar nerves in three groups of participants – Drivers (driving taxi/microbus for at least six months), Helpers (microbus conductors for at least six months) and Controls (college staff/students). Parameters for sensory nerve action potentials and compound motor action potentials were compared among groups by ANOVA and right versus left sides within groups by paired t test. Results: The study involved 145 male participants – 51 Drivers, 34 Helpers and 60 Controls. Compared to drivers and helpers, conduction velocity of nerves was significantly higher in controls for sensory component of all nerves (p values for right median = 0.001, left median = <0.001, right ulnar = <0.001 and left ulnar = 0.019) and motor component of right ulnar nerve (p=0.002). In right-left comparisons, conduction was slower in left median sensory than right (p=0.001) and right ulnar sensory than left (p=0.015) in the helpers but not significant in other groups. Conclusion: Electrophysiological evidences of afflictions of median and ulnar nerves are detectable in urban taxi/ microbus drivers and helpers with at least six months’ occupational duration.

31 December 2019 in Janaki Medical College Journal of Medical Science
Verified
Journal Article
Closed access
PDF file
MAMrigendra Amatya
Mrigendra Amatya
KOK. Oli
K. Oli
SPS. Pokhrel
S. Pokhrel
SSS. Shrestha
S. Shrestha
Background and Objectives: Ingestion of plain water is associated with an acute rise in blood pressure, probably due to elicitation of a sympathetic reflex in patients with autonomic dysfunction. Whether the pressor response is similar in healthy individuals is disputed. Other types of fluid could have different effects. Comparison of the pressor effects of plain water ingestion with other types of fluids has been reported scantily. Material and methods: In a cross-over experimental study, young medical students ingested 500 mL of plain water (PW), 500 mL of oral rehydration salt solution (ORS), or 400 mL of commercial fruit juice (FJ) on separate days, with at least two days’ gap. Their heart rate (HR) and blood pressure (BP: systolic, SBP and diastolic, DBP) were recorded before, immediately after (0 min), and at 2, 5, 20, and 40 min after fluid ingestion and compared with baseline values. Results: Sixty nine apparently healthy medical students (40 males and 29 females, age range 18-24 years) participated in the study. Compared to baseline, SBP and DBP were significantly higher at 0, 2, and 5 min measurements with ORS and FJ; then lowered at 20 and 40 min. With the PW, BP changes were not significant at any time of measurement. In all experimental set ups, HR increased significantly at 0, 2, and 5 min and lowered to near baseline levels then after. Conclusion: Ingestion of ORS and FJ, but not PW, is associated with acute pressor effects in healthy young adults. This finding could have implications on the choice of fluid for prophylaxis in hypotensive conditions such as blood donation, postural hypotension, and autonomic dysfunction.