Kolbjørn Lindberg

Kolbjørn Lindberg

Auto-generated profile, based on publicly available information

Kolbjørn Lindberg

Department of Sport Science and Physical Education, Faculty of Health and Sport Sciences, University of Agder, Kristiansand, Norway

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KLKolbjørn Lindberg
Kolbjørn Lindberg
PSPaul Solberg
Paul Solberg
TBThomas Bjørnsen
Thomas Bjørnsen
CHChristian Helland
Christian Helland
BRBent Rønnestad
Bent Rønnestad
GPGøran Paulsen
Gøran Paulsen
The aim of the study was to examine the test-retest reliability and agreement across methods for assessing individual force-velocity (FV) profiles of the lower limbs in athletes. Using a multicenter approach, 27 male athletes completed all measurements for the main analysis, with up to 82 male and female athletes on some measurements. The athletes were tested twice before and twice after a 2- to 6-month period of regular training and sport participation. The double testing sessions were separated by ~1 week. Individual FV-profiles were acquired from incremental loading protocols in squat jump (SJ), countermovement jump (CMJ) and leg press. A force plate, linear encoder and a flight time calculation method were used for measuring force and velocity during SJ and CMJ. A linear regression was fitted to the average force and velocity values for each individual test to extrapolate the FV-variables: theoretical maximal force (F0), velocity (V0), power (Pmax), and the slope of the FV-profile (SFV). Despite strong linearity (R2>0.95) for individual FV-profiles, the SFV was unreliable for all measurement methods assessed during vertical jumping (coefficient of variation (CV): 14–30%, interclass correlation coefficient (ICC): 0.36–0.79). Only the leg press exercise, of the four FV-variables, showed acceptable reliability (CV:3.7–8.3%, ICC:0.82–0.98). The agreement across methods for F0 and Pmax ranged from (Pearson r): 0.56–0.95, standard error of estimate (SEE%): 5.8–18.8, and for V0 and SFV r: -0.39–0.78, SEE%: 12.2–37.2. With a typical error of 1.5 cm (5–10% CV) in jump height, SFV and V0 cannot be accurately obtained, regardless of the measurement method, using a loading range corresponding to 40–70% of F0. Efforts should be made to either reduce the variation in jumping performance or to assess loads closer to the FV-intercepts. Coaches and researchers should be aware of the poor reliability of the FV-variables obtained from vertical jumping, and of the differences across measurement methods.

2 September 2021 in Scandinavian Journal of Medicine & Science in Sports
Verified
Journal Article
Open access
PDF file
KLKolbjørn Lindberg
Kolbjørn Lindberg
PSPaul Solberg
Paul Solberg
BRBent R. Rønnestad
Bent R. Rønnestad
MFMartin Thorsen Frank
Martin Thorsen Frank
TLTommy Larsen
Tommy Larsen
TBThomas Bjørnsen
Thomas Bjørnsen
The present study aimed to examine the effectiveness of an individualized training program based on force‐velocity (FV) profiling on jumping, sprinting, strength, and power in athletes. Forty national level team sport athletes (20 ± 4years, 83 ± 13 kg) from ice‐hockey, handball, and soccer completed a 10‐week training intervention. A theoretical optimal squat jump (SJ)‐FV‐profile was calculated from SJ with five different loads (0, 20, 40, 60, and 80 kg). Based on their initial FV‐profile, athletes were randomized to train toward, away, or irrespective (balanced training) of their initial theoretical optimal FV‐profile. The training content was matched between groups in terms of set x repetitions but varied in relative loading to target the different aspects of the FV‐profile. The athletes performed 10 and 30 m sprints, SJ and countermovement jump (CMJ), 1 repetition maximum (1RM) squat, and a leg‐press power test before and after the intervention. There were no significant group differences for any of the performance measures. Trivial to small changes in 1RM squat (2.9%, 4.6%, and 6.5%), 10 m sprint time (1.0%, −0.9%, and −1.7%), 30 m sprint time (0.9%, −0.6%, and −0.4%), CMJ height (4.3%, 3.1%, and 5.7%), SJ height (4.8%, 3.7%, and 5.7%), and leg‐press power (6.7%, 4.2%, and 2.9%) were observed in the groups training toward, away, or irrespective of their initial theoretical optimal FV‐profile, respectively. Changes toward the optimal SJ‐FV‐profile were negatively correlated with changes in SJ height (r = −0.49, p < 0.001). Changes in SJ‐power were positively related to changes in SJ‐height (r = 0.88, p < 0.001) and CMJ‐height (r = 0.32, p = 0.044), but unrelated to changes in 10 m (r = −0.02, p = 0.921) and 30 m sprint time (r = −0.01, p = 0.974). The results from this study do not support the efficacy of individualized training based on SJ‐FV profiling.

18 March 2023 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Open access
MBMaarten F. Bobbert
Maarten F. Bobbert
KLKolbjørn Lindberg
Kolbjørn Lindberg
TBThomas Bjørnsen
Thomas Bjørnsen
PSPaul Solberg
Paul Solberg
GPGøran Paulsen
Gøran Paulsen
Introduction: Force–velocity profiling has been proposed in the literature as a method to identify the overall mechanical characteristics of lower extremities. A force–velocity profile is obtained by plotting for jumps at different loads the effective work as a function of the average push-off velocity, fitting a straight line to the results, and extrapolating this line to find the theoretical maximum isometric force and unloaded shortening velocity. Here we investigated whether the force–velocity profile and its characteristics can be related to the intrinsic force–velocity relationship. Methods: We used simulation models of various complexity, ranging from a simple mass actuated by a linearly damped force to a planar musculoskeletal model comprising four segments and six muscle–tendon complexes. The intrinsic force–velocity relationship of each model was obtained by maximizing the effective work during isokinetic extension at different velocities. Results: Several observations were made. First, at the same average velocity, less effective work can be done during jumping than during isokinetic lower extremity extension at this velocity. Second, the intrinsic relationship is curved; fitting a straight line and extrapolating it seem arbitrary. Third, the maximal isometric force and the maximal velocity corresponding to the profile are not independent. Fourth, they both vary with inertial properties of the system. Conclusions: For these reasons, we concluded that the force–velocity profile is specific for the task and is just what it is: the relationship between effective work and an arbitrary estimate of average velocity; it does not represent the intrinsic force–velocity relationship of the lower extremities.

1 December 2021 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
PDF file
KLKolbjørn Lindberg
Kolbjørn Lindberg
IEIngrid Eythorsdottir
Ingrid Eythorsdottir
PSPaul Solberg
Paul Solberg
ØGØyvind Gløersen
Øyvind Gløersen
OSOlivier Seynnes
Olivier Seynnes
GPGøran Paulsen
Gøran Paulsen
Purpose: The aim of this study was to examine the concurrent validity of force–velocity (FV) variables assessed across 5 Keiser leg press devices. Methods: A linear encoder and 2 independent force plates (MuscleLab devices) were mounted on each of the 5 leg press devices. A total of 997 leg press executions, covering a wide range of forces and velocities, were performed by 14 participants (29 [7] y, 181 [5] cm, 82 [8] kg) across the 5 devices. Average and peak force, velocity, and power values were collected simultaneously from the Keiser and MuscleLab devices for each repetition. Individual FV profiles were fitted to each participant from peak and average force and velocity measurements. Theoretical maximal force, velocity, and power were deduced from the FV relationship. Results: Average and peak force and velocity had a coefficient of variation of 1.5% to 8.6%, near-perfect correlations (.994–.999), and a systematic bias of 0.7% to 7.1% when compared with reference measurements. Average and peak power showed larger coefficient of variations (11.6% and 17.2%), despite excellent correlations (.977 and .952), and trivial to small biases (3.9% and 8.4%). Extrapolated FV variables showed near-perfect correlations (.983–.997) with trivial to small biases (1.4%–11.2%) and a coefficient of variation of 1.4% to 5.9%. Conclusions: The Keiser leg press device can obtain valid measurements over a wide range of forces and velocities across different devices. To accurately measure power, theoretical maximal power calculated from the FV profile is recommended over average and peak power values from single repetitions, due to the lower random error observed for theoretical maximal power.

1 July 2022 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
PDF file
KLKolbjørn Lindberg
Kolbjørn Lindberg
PSPaul Solberg
Paul Solberg
TBThomas Bjørnsen
Thomas Bjørnsen
CHChristian Helland
Christian Helland
BRBent Rønnestad
Bent Rønnestad
GPGøran Paulsen
Gøran Paulsen
Purpose: This study examined the test–retest reliability of common assessments for measuring strength and power of the lower body in high-performing athletes. Methods: A total of 100 participants, including both male (n = 83) and female (n = 17) athletes (21 [4] y, 182 [9] cm, and 78 [12] kg), were recruited for this study, using a multicenter approach. The participants underwent physical testing 4 times. The first 2 sessions (1 and 2) were separated by ∼1 week, followed by a period of 2 to 6 months, whereas the last 2 sessions (3 and 4) were again separated by ∼1 week. The test protocol consisted of squat jumps, countermovement jumps, jump and reach, 30-m sprint, 1-repetition-maximum squat, sprint cycling, and a leg-press test. Results: The typical error (%) ranged from 1.3% to 8.5% for all assessments. The change in means ranged from −1.5% to 2.5% for all assessments, whereas the interclass correlation coefficient ranged from .85 to .97. The smallest worthwhile change (0.2 of baseline SD) ranged from 1.2% to 5.0%. The ratio between the typical error (%) and the smallest worthwhile change (%) ranged from 0.5 to 1.2. When observing the reliability across testing centers, considerable differences in reliability were observed (typical error [%] ratio: 0.44–1.44). Conclusions: Most of the included assessments can be used with confidence by researchers and coaches to measure strength and power in athletes. Our results highlight the importance of controlling testing reliability at each testing center and not relying on data from others, despite having applied the same protocol.

22 March 2022 in Scandinavian Journal of Medicine & Science in Sports
Verified
Journal Article
Open access
KLKolbjørn Lindberg
Kolbjørn Lindberg
HLHilde Lohne‐Seiler
Hilde Lohne‐Seiler
SFSindre H. Fosstveit
Sindre H. Fosstveit
ESErlend E. Sibayan
Erlend E. Sibayan
JFJoachim S. Fjeller
Joachim S. Fjeller
TBThomas Bjørnsen
Thomas Bjørnsen
The study aimed to investigate the effectiveness of an individualized power training program based on force–velocity (FV) profiling on physical function, muscle morphology, and neuromuscular adaptations in older men. Forty‐nine healthy men (68 ± 5 years) completed a 10‐week training period to enhance muscular power. They were randomized to either a generic power training group (GPT) or an individualized power training group (IPT). Unlike generic training, individualized training was based on low‐ or high‐resistance exercises, from an initial force–velocity profile. Lower‐limb FV profile was measured in a pneumatic leg‐press, and physical function was assessed as timed up‐and‐go time (TUG), sit‐to‐stand power, grip strength, and stair‐climbing time (loaded [20kg] and unloaded). Vastus lateralis morphology was measured with ultrasonography. Rate of force development (RFD) and rate of myoelectric activity (RMA) were measured during an isometric knee extension. The GPT group improved loaded stair‐climbing time (6.3 ± 3.8 vs. 2.3% ± 7.3%, p = 0.04) more than IPT. Both groups improved stair‐climbing time, sit to stand, and leg press power, grip strength, muscle thickness, pennation angle, fascicle length, and RMA from baseline (p < 0.05). Only GPT increased loaded stair‐climbing time and RFD (p < 0.05). An individualized power training program based on FV profiling did not improve physical function to a greater degree than generic power training. A generic power training approach combining both heavy and low loads might be advantageous through eliciting both force‐ and velocity‐related neuromuscular adaptions with a concomitant increase in muscular power and physical function in older men.