Dragan Kostić

Dragan Kostić

Auto-generated profile, based on publicly available information

Dragan Kostić

ASMPT, Beuningen, The Netherlands

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2022 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
LELuke F. van Eijk
Luke F. van Eijk
SBStijn Beer
Stijn Beer
RERobin M. J. van Es
Robin M. J. van Es
DKDragan Kostić
Dragan Kostić
Henk NijmeijerHenk Nijmeijer
Henk Nijmeijer
This brief investigates frequency-domain properties of the hybrid integrator-gain system (HIGS) by analytically deriving its higher-order sinusoidal input describing functions (HOSIDFs). Furthermore, a novel application of this nonlinear control element is proposed, where it is utilized as a nonlinear lag filter. Hereby, the closed-loop stability can be guaranteed based on a non-parametric plant model—while ensuring robustness against plant uncertainties—by utilizing a circle criterion-like argument. Control design is initially based on a describing function (DF) analysis of the HIGS. This yields magnitude characteristics similar to those of a linear lag filter, while having the freedom to tune the induced phase lag. However, the excitation of higher-order harmonics by the HIGS is, in that case, neglected. Based on the derived HOSIDFs, it is shown that the validity of this assumption depends on the properties of the plant and the controller, as well as the spectral properties of the external inputs. Finally, the potential of the nonlinear lag filter is investigated by means of simulations and experiments on a high-precision industrial motion stage, showing performance improvements compared with a linear lag filter.

19 March 2024 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Open access
DCDaniel Caporale
Daniel Caporale
LELuke F. van Eijk
Luke F. van Eijk
NKNima Karbasizadeh
Nima Karbasizadeh
SBStijn Beer
Stijn Beer
DKDragan Kostić
Dragan Kostić
HHHassan HosseinNia
Hassan HosseinNia
In this work, the proportional Clegg integrator (PCI), a resetting proportional-integrator (PI) element, is studied with the aim of improving the performance of an industrial motion stage currently controlled by a linear controller. A novel parallel continuous reset (CR) architecture, based on the PI, is presented, along with frequency-based tuning guidelines, similar to linear time-invariant (LTI) loopshaping techniques. Open-loop higher order sinusoidal input describing functions (HOSIDFs) and pseudo-sensitivities computed through analytically derived approximate closed-loop HOSIDFs were effectively applied to predict steady-state performance. The experimental results, obtained on a wire bonding machine, confirmed that resonance-induced vibrations of the machine’s base frame can be suppressed more effectively by adopting a PCI-PID controller compared to the currently used linear controller. The novel structure does not only reduce unwanted excitation of higher order harmonics of the base frame resonance, such as the series CR architecture recently introduced in literature, but also avoids amplification of noise when implemented in practice. With the novel parallel structure, a significant (32%) decrease in the root mean square (rms) of the settling error could be achieved when compared to the linear controller currently used and the series CR reset structure.

16 April 2024 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
MPMaurice Poot
Maurice Poot
MHMax van Haren
Max van Haren
DKDragan Kostić
Dragan Kostić
JPJim Portegies
Jim Portegies
TOTom Oomen
Tom Oomen
The requirements for high accuracy and throughput in next-generation data-intensive motion systems lead to situations where position-dependent feedforward is essential. This article aims to develop a framework for interpretable and task-flexible position-dependent feedforward through systematic learning with automated experimental design. A data-driven and interpretable framework is developed by employing Gaussian process (GP) regression, enabling accurate modeling of feedforward parameters as a continuous function of position. The data is efficiently collected and illustrated through an iterative learning control (ILC) algorithm. Moreover, a framework for experimental design in the sense of automatically determining the training positions is presented by exploiting the uncertainty estimates of the GP and the specified first-principles knowledge. Two relevant case studies show the importance and significant performance improvement of the approach for position-dependent snap feedforward for a simplified 1-D wafer stage simulation and experimental application to position-dependent motor force constant compensation in an industrial wirebonder.

13 August 2024 in IEEE Transactions on Automatic Control
Verified
Journal Article
Open access
LELuke F. van Eijk
Luke F. van Eijk
DKDragan Kostić
Dragan Kostić
MKMohammad Khosravi
Mohammad Khosravi
HHHassan HosseinNia
Hassan HosseinNia
This article introduces output prediction methods for two types of systems containing sinusoidal-input uniformly convergent (SIUC) elements. The first method considers these elements in combination with single-input single-output linear time-invariant (LTI) systems before, after, and in parallel to them. The second method considers a multiple-input multiple-output LTI system where each input is controlled by a SIUC element. The output prediction only requires frequency-response functions of the LTI elements and is fully accurate for sinusoidal inputs.

1 March 2026 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
SHS. Ali Hosseini
S. Ali Hosseini
FQFabian R. Quinten
Fabian R. Quinten
LELuke F. van Eijk
Luke F. van Eijk
DKDragan Kostić
Dragan Kostić
HHHassan HosseinNia
Hassan HosseinNia
This study introduces a modified version of the constant-in-gain, lead-in-phase (CgLp) filter, which incorporates a feedthrough term in the first-order reset element (FORE) to reduce the undesirable nonlinearities and achieve an almost constant gain across all frequencies. A backward calculation approach is proposed to derive the additional parameter introduced by the feedthrough term, enabling designers to easily tune the filter to generate the required phase. This article also presents an add-on filter structure that can enhance the performance of an existing LTI controller without altering its robustness margins. A sensitivity improvement indicator is proposed to guide the tuning process, enabling designers to visualize the improvements in closed-loop performance. The proposed methodology is demonstrated through a case study of an industrial wire bonder machine, showcasing its effectiveness in addressing low-frequency vibrations and improving overall control performance.

19 June 2025 in IEEE Control Systems Letters
Verified
Journal Article
Open access
LELuke F. van Eijk
Luke F. van Eijk
DKDragan Kostić
Dragan Kostić
HHHassan HosseinNia
Hassan HosseinNia
This article introduces an output prediction method for a general class of closed-loop reset control systems. The considered type of system consists of a linear time-invariant (LTI) part which is connected in feedback with a reset controller that (partially) resets (a part of) its states when its input is equal to zero. Given some practical assumptions on the reset element’s input signal, the system output can be accurately predicted when the system is subject to a sinusoidal input. One benefit of this approach is that it provides an intuitive frequency-domain representation of the system. Another benefit is that output prediction can be done based solely on a frequency-response function (FRF) of the LTI part of the system. This article also introduces an accurate and computationally efficient algorithm which can – based on the predicted output – compute a closed-loop pseudo-sensitivity. This pseudo-sensitivity represents the ratio between the maximum absolute value of the system’s output and the amplitude of its input, similar to the closed-loop sensitivity functions for LTI systems.