Ruipeng Li

Ruipeng Li

Auto-generated profile, based on publicly available information

Ruipeng Li

Department of Civil & Environmental Engineering, University of Maryland, College Park, MD 20742, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
LTLewei Tong
Lewei Tong
YZYunfeng Zhang
Yunfeng Zhang
LZLyu Zhang
Lyu Zhang
HLHeng Liu
Heng Liu
ZZZhiping Zhang
Zhiping Zhang
RLRuipeng Li
Ruipeng Li

11 June 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
YGYongsheng Gao
Yongsheng Gao
RLRuipeng Li
Ruipeng Li
In-process measurement can provide feedback for the control of workpiece precision in terms of size, roughness and, in particular, mid-spatial frequency form error. Optical measurement methods are of the non-contact type and possess high precision, as required for in-process form error measurement. In precision machining, coolant is commonly used to reduce heat generation and thermal deformation on the workpiece surface. However, the use of coolant will induce an opaque coolant barrier if optical measurement methods are used. In this paper, a new multiple air beam approach is proposed. The new approach permits the displacement of coolant from any direction and with a large thickness, i.e. with a large amount of coolant. The model, the working principle, and the key features of the new approach are presented. Based on the proposed new approach, a new in-process form error optical measurement system is developed. The coolant removal capability and the performance of this new multiple air beam approach are assessed. The experimental results show that the workpiece surface y ( x , z ) can be measured successfully with standard deviation up to 0.3011 µ m even under a large amount of coolant, such that the coolant thickness is 15 mm. This means a relative uncertainty of 2 σ up to 4.35% and the workpiece surface is deeply immersed in the opaque coolant. The results also show that, in terms of coolant removal capability, air supply and air velocity, the proposed new approach improves by, respectively, 3.3, 1.3 and 5.3 times on the previous single air beam approach. The results demonstrate the significant improvements brought by the new multiple air beam method together with the developed measurement system.