Robert Groth

Robert Groth

Auto-generated profile, based on publicly available information

Robert Groth

Queensland University of Technology

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2021 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
RGRobert Groth
Robert Groth
LCLuke T. Cravigan
Luke T. Cravigan
SNSadegh Niazi
Sadegh Niazi
ZRZoran Ristovski
Zoran Ristovski
GJGraham R. Johnson
Graham R. Johnson
The airborne dynamics of respiratory droplets, and the transmission routes of pathogens embedded within them, are governed primarily by the diameter of the particles. These particles are composed of the fluid which lines the respiratory tract, and is primarily mucins and salts, which will interact with the atmosphere and evaporate to reach an equilibrium diameter. Measuring organic volume fraction (OVF) of cough aerosol has proved challenging due to large variability and low material volume produced after coughing. Here, the diametric hygroscopic growth factors (GF) of the cough aerosol produced by healthy participants were measured in situ using a rotating aerosol suspension chamber and a humidification tandem differential mobility analyser. Using hygroscopicity models, it was estimated that the average OVF in the evaporated cough aerosol was 0.88 ± 0.07 and the average GF at 90% relative humidity (RH) was 1.31 ± 0.03. To reach equilibrium in dry air the droplets will reduce in diameter by a factor of approximately 2.8 with an evaporation factor of 0.36 ± 0.05. Hysteresis was observed in cough aerosol at RH = ∼35% and RH = ∼65% for efflorescence and deliquescence, respectively, and may depend on the OVF. The same behaviour and GF were observed in nebulized bovine bronchoalveolar lavage fluid.

19 July 2022 in Environmental Science & Technology
Verified
Journal Article
Closed access
RGRobert Groth
Robert Groth
SNSadegh Niazi
Sadegh Niazi
GJGraham R. Johnson
Graham R. Johnson
ZRZoran Ristovski
Zoran Ristovski

14 February 2024 in Environmental Science & Technology
Verified
Journal Article
Closed access
RGRobert Groth
Robert Groth
SNSadegh Niazi
Sadegh Niazi
HOHenry P. Oswin
Henry P. Oswin
AHAllen E. Haddrell
Allen E. Haddrell
KSKirsten Spann
Kirsten Spann
ZRZoran Ristovski
Zoran Ristovski

TNTham Thi Nguyen
Tham Thi Nguyen
CHCongrong He
Congrong He
RCRobyn Carter
Robyn Carter
EBEmma L. Ballard
Emma L. Ballard
KSKim Smith
Kim Smith
Knibbs LukeKnibbs Luke
Knibbs Luke
Pseudomonas aeruginosa (Pa) is the predominant bacterial pathogen in people with cystic fibrosis (CF) and can be transmitted by airborne droplet nuclei. Little is known about the ability of ultraviolet band C (UV-C) irradiation to inactivate Pa at doses and conditions relevant to implementation in indoor clinical settings. We assessed the effectiveness of UV-C (265 nm) at up to seven doses on the decay of nebulized Pa aerosols (clonal Pa strain) under a range of experimental conditions. Experiments were done in a 400 L rotating sampling drum. A six-stage Andersen cascade impactor was used to collect aerosols inside the drum and the particle size distribution was characterized by an optical particle counter. UV-C effectiveness was characterized relative to control tests (no UV-C) of the natural decay of Pa. We performed 112 tests in total across all experimental conditions. The addition of UV-C significantly increased the inactivation of Pa compared with natural decay alone at all but one of the UV-C doses assessed. UV-C doses from 246–1968 µW s/cm2 had an estimated effectiveness of approximately 50–90% for airborne Pa. The effectiveness of doses ≥984 µW s/cm2 were not significantly different from each other (p-values: 0.365 to ~1), consistent with a flattening of effectiveness at higher doses. Modelling showed that delivering the highest dose associated with significant improvement in effectiveness (984 µW s/cm2) to the upper air of three clinical rooms would lead to lower room doses from 37–49% of the 8 h occupational limit. Our results suggest that UV-C can expedite the inactivation of nebulized airborne Pa under controlled conditions, at levels that can be delivered safely in occupied settings. These findings need corroboration, but UV-C may have potential applications in locations where people with CF congregate, coupled with other indoor and administrative infection control measures.

14 May 2026 in ACS ES&T Air
Verified
Journal Article
Closed access
BABehnaz Alinaghipour
Behnaz Alinaghipour
SNSadegh Niazi
Sadegh Niazi
RGRobert Groth
Robert Groth
BMBranka Miljevic
Branka Miljevic
ZRZoran Ristovski
Zoran Ristovski

1 June 2022 in ChemRxiv
Verified
Preprint
Open access
PDF file
RGRobert Groth
Robert Groth
SNSadegh Niazi
Sadegh Niazi
GJGraham Johnson
Graham Johnson
ZRZoran Ristovski
Zoran Ristovski
The impact of respiratory particle composition on the equilibrium morphology and phase are not well understood. Furthermore, the effects of these different phases and morphologies on the viability of viruses embedded within these particles are equally unknown. Physiologically relevant respiratory fluid analogues were constructed, and their hygroscopic behavior were measured using an ensemble technique. A relationship between hygroscopicity and protein concentration was determined, providing additional validation to the high protein content of respiratory aerosol measured in prior works (>90%). It was found that the salt component of the respiratory particles could crystallize as a single crystal, multiple crystals, or would not crystallize at all. It was found that dried protein particles at indoor-relevant climatic conditions could exist separately in a glassy (~77% of particles) or viscoelastic state (~23% of particles). The phase state and morphology of respiratory particles may influence the viability of embedded pathogens. We recommend that pathogen research aiming to mimic the native composition of respiratory fluid should use a protein concentration of at least 90% by solute volume to improve the representativity of the pathogen’s microenvironment.