Paul J. C. Hughes

Paul J. C. Hughes

Auto-generated profile, based on publicly available information

Paul J. C. Hughes

POLARIS, Division of Clinical Medicine School of Medicine and Population Health, University of Sheffield Sheffield United Kingdom

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2017 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
CJChristopher S. Johns
Christopher S. Johns
ASAndrew J. Swift
Andrew J. Swift
SRSmitha Rajaram
Smitha Rajaram
PHPaul J.C. Hughes
Paul J.C. Hughes
DCDavid J. Capener
David J. Capener
JWJim M. Wild
Jim M. Wild
Purpose: To assess the diagnostic accuracy of magnetic resonance imaging (MRI) perfusion against perfusion single photon emission tomography (SPECT) screening for chronic thromboembolic pulmonary hypertension (CTEPH). Ventilation/perfusion (V/Q) scintigraphy is recommended to screen for suspected CTEPH. It has previously been shown that 3D dynamic contrast‐enhanced (DCE) lung perfusion MRI has a similar sensitivity for diagnosing CTEPH in comparison to planar perfusion scintigraphy; however, planar scintigraphy has now been largely replaced by SPECT, due to higher spatial resolution and sensitivity.Materials and Methods: Consecutive patients with suspected CTEPH or unexplained pulmonary hypertension attending a referral center, who underwent lung DCE perfusion MRI at 1.5T, perfusion SPECT, and computed tomography pulmonary angiography (CTPA) within 14 days of right heart catheterization, from April 2013 to April 2014, were included. DCE‐MR, SPECT, and CTPA were independently analyzed by two blinded radiologists. Disagreements were corrected by consensus. The gold standard reference for the diagnosis of chronic thromboemboli was based on a review of multimodality imaging and clinical findings.Results: In all, 74 patients with suspected CTEPH underwent all three modalities. Forty‐six were diagnosed with CTEPH (36) or chronic thromboembolic disease (CTED) (10). 3D DCE perfusion MRI correctly identified all patients (sensitivity of 100%), compared with a 97% sensitivity for SPECT.Conclusion: DCE lung perfusion MRI has increased sensitivity when compared with perfusion scintigraphy in screening for CTEPH. As MRI does not use ionizing radiation, it should be considered as a first‐line imaging modality in suspected CTEPH.Level of Evidence: 3Technical Efficacy: Stage 3J. Magn. Reson. Imaging 2017;46:1693–1697.

6 March 2017 in Thorax
Verified
Journal Article
Open access
PDF file
HMHelen Marshall
Helen Marshall
AHAlex Horsley
Alex Horsley
CTChris J Taylor
Chris J Taylor
LSLaurie Smith
Laurie Smith
DHDavid Hughes
David Hughes
JWJim M. Wild
Jim M. Wild
Hyperpolarised 3He ventilation-MRI, anatomical lung MRI, lung clearance index (LCI), low-dose CT and spirometry were performed on 19 children (6–16 years) with clinically stable mild cystic fibrosis (CF) (FEV1>−1.96), and 10 controls. All controls had normal spirometry, MRI and LCI. Ventilation-MRI was the most sensitive method of detecting abnormalities, present in 89% of patients with CF, compared with CT abnormalities in 68%, LCI 47% and conventional MRI 22%. Ventilation defects were present in the absence of CT abnormalities and in patients with normal physiology, including LCI. Ventilation-MRI is thus feasible in young children, highly sensitive and provides additional information about lung structure–function relationships.

5 March 2018 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
NSNeil J. Stewart
Neil J. Stewart
Ho-Fung ChanHo-Fung Chan
Ho-Fung Chan
PHPaul J.C. Hughes
Paul J.C. Hughes
FHFelix C. Horn
Felix C. Horn
GNGraham Norquay
Graham Norquay
JWJim M. Wild
Jim M. Wild
To support translational lung MRI research with hyperpolarized 129Xe gas, comprehensive evaluation of derived quantitative lung function measures against established measures from 3He MRI is required. Few comparative studies have been performed to date, only at 3T, and multisession repeatability of 129Xe functional metrics have not been reported. To compare hyperpolarized 129Xe and 3He MRI-derived quantitative metrics of lung ventilation and microstructure, and their repeatability, at 1.5T. Retrospective. Fourteen healthy nonsmokers (HN), five exsmokers (ES), five patients with chronic obstructive pulmonary disease (COPD), and 16 patients with nonsmall-cell lung cancer (NSCLC). 1.5T. NSCLC, COPD patients and selected HN subjects underwent 3D balanced steady-state free-precession lung ventilation MRI using both 3He and 129Xe. Selected HN, all ES, and COPD patients underwent 2D multislice spoiled gradient-echo diffusion-weighted lung MRI using both hyperpolarized gas nuclei. Ventilated volume percentages (VV%) and mean apparent diffusion coefficients (ADC) were derived from imaging. COPD patients performed the whole MR protocol in four separate scan sessions to assess repeatability. Same-day pulmonary function tests were performed. Intermetric correlations: Spearman's coefficient. Intergroup/internuclei differences: analysis of variance / Wilcoxon's signed rank. Repeatability: coefficient of variation (CV), intraclass correlation (ICC) coefficient. A significant positive correlation between 3He and 129Xe VV% was observed (r = 0.860, P < 0.001). VV% was larger for 3He than 129Xe (P = 0.001); average bias, 8.79%. A strong correlation between mean 3He and 129Xe ADC was obtained (r = 0.922, P < 0.001). MR parameters exhibited good correlations with pulmonary function tests. In COPD patients, mean CV of 3He and 129Xe VV% was 4.08% and 13.01%, respectively, with ICC coefficients of 0.541 (P = 0.061) and 0.458 (P = 0.095). Mean 3He and 129Xe ADC values were highly repeatable (mean CV: 2.98%, 2.77%, respectively; ICC: 0.995, P < 0.001; 0.936, P < 0.001). 129Xe lung MRI provides near-equivalent information to 3He for quantitative lung ventilation and microstructural MRI at 1.5T. Level of Evidence: 3 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2018.

30 November 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
GCGuilhem J. Collier
Guilhem J. Collier
JEJames A. Eaden
James A. Eaden
PHPaul J. C. Hughes
Paul J. C. Hughes
SBStephen M. Bianchi
Stephen M. Bianchi
NSNeil J. Stewart
Neil J. Stewart
JWJim M. Wild
Jim M. Wild

25 October 2018 in European Respiratory Journal
Verified
Journal Article
Closed access
PDF file
LSLaurie J. Smith
Laurie J. Smith
GCGuilhem J. Collier
Guilhem J. Collier
HMHelen Marshall
Helen Marshall
PHPaul J.C. Hughes
Paul J.C. Hughes
ABAlberto M. Biancardi
Alberto M. Biancardi
JWJim M. Wild
Jim M. Wild
Hyperpolarised helium-3 (3He) ventilation magnetic resonance imaging (MRI) and multiple-breath washout (MBW) are sensitive methods for detecting lung disease in cystic fibrosis (CF). We aimed to explore their relationship across a broad range of CF disease severity and patient age, as well as assess the effect of inhaled lung volume on ventilation distribution.32 children and adults with CF underwent MBW and3He-MRI at a lung volume of end-inspiratory tidal volume (EIVT). In addition, 28 patients performed3He-MRI at total lung capacity.3He-MRI scans were quantitatively analysed for ventilation defect percentage (VDP), ventilation heterogeneity index (VHI) and the number and size of individual contiguous ventilation defects. From MBW, the lung clearance index, convection-dependent ventilation heterogeneity (Scond) and convection–diffusion-dependent ventilation heterogeneity (Sacin) were calculated.VDP and VHI at EIVTstrongly correlated with lung clearance index (r=0.89 and r=0.88, respectively), Sacin (r=0.84 and r=0.82, respectively) and forced expiratory volume in 1 s (FEV1) (r=−0.79 and r=−0.78, respectively). Two distinct3He-MRI patterns were highlighted: patients with abnormal FEV1had significantly (p<0.001) larger, but fewer, contiguous defects than those with normal FEV1, who tended to have numerous small volume defects. These two MRI patterns were delineated by a VDP of ∼10%. At total lung capacity, when compared to EIVT, VDP and VHI reduced in all subjects (p<0.001), demonstrating improved ventilation distribution and regions of volume-reversible and nonreversible ventilation abnormalities.

6 July 2020 in European Respiratory Journal
Verified
Journal Article
Closed access
PDF file
LSLaurie J. Smith
Laurie J. Smith
AHAlex Horsley
Alex Horsley
JBJody Bray
Jody Bray
PHPaul J.C. Hughes
Paul J.C. Hughes
ABAlberto Biancardi
Alberto Biancardi
JWJim M. Wild
Jim M. Wild
Introduction: Xenon-129 (129Xe) ventilation magnetic resonance imaging (MRI) is sensitive to detect early cystic fibrosis (CF) lung disease and response to treatment.129Xe-MRI could play a significant role in clinical trials and patient management. Here we present data on the repeatability of imaging measurements and their sensitivity to longitudinal change.Methods: 29 children and adults with CF and a range of disease severity were assessed twice, a median (interquartile range (IQR)) of 16.0 (14.4–19.5) months apart. Patients underwent129Xe-MRI, lung clearance index (LCI), body plethysmography and spirometry at both visits. 11 patients repeated129Xe-MRI in the same session to assess the within-visit repeatability. The ventilation defect percentage (VDP) was the primary metric calculated from129Xe-MRI.Results: At baseline, mean±sdage was 23.0±11.1 years and forced expiratory volume in 1 s (FEV1) z-score was −2.2±2.0. Median (IQR) VDP was 9.5 (3.4–31.6)% and LCI was 9.0 (7.7–13.7). Within- and inter-visit repeatability of VDP was high. At 16 months there was no single trend of129Xe-MRI disease progression. Visible129Xe-MRI ventilation changes were common, which reflected changes in VDP. Based on the within-visit repeatability, a significant short-term change in VDP is >±1.6%. For longer-term follow-up, changes in VDP of up to ±7.7% can be expected, or ±4.1% for patients with normal FEV1. No patient had a significant change in FEV1; however, 59% had change in VDP >±1.6%. In patients with normal FEV1, there were significant changes in ventilation and in VDP.Conclusions: 129Xe-MRI is a highly effective method for assessing longitudinal lung disease in patients with CF. VDP has great potential as a sensitive clinical outcome measure of lung function and end-point for clinical trials.