Carsten Dahl Mørch

Carsten Dahl Mørch

Auto-generated profile, based on publicly available information

Carsten Dahl Mørch

Aalborg University

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2016 in Somatosensory & Motor Research
Verified
Journal Article
Closed access
YIY. Imai
Y. Imai
KPK. K. Petersen
K. K. Petersen
CMC. D. Mørch
C. D. Mørch
LALars Arendt-Nielsen
Lars Arendt-Nielsen
This study aimed to compare the reliability and magnitude of conditioned pain modulation (CPM) by applying different test stimuli (TS) and conditioning stimuli (CS). Twenty-six healthy male participants were recruited in the study of two identical sessions. In each session, four TS (electrical, heat, handheld, and cuff pressure algometry) were applied before and during CS (cold pressor test (CPT) or cuff algometry). The same procedure was repeated with 45-min intervals, but with the other CS. Five thresholds were measured including four pain detection thresholds from four TS and pain tolerance threshold from cuff TS (cuff PTT). Intraclass correlation coefficient (ICC (3,1)) and coefficient of variation (CV) were calculated as measures of reliability. The reliability of TS before and during CS was good for all combinations (ICC: 0.60–0.96, CV: 2.2–22.9%), but the reliability of the CPM effect varied (ICC: 0.04–0.53, CV: 63.6–503.9%). The most reliable combinations were considered to be the handheld pressure pain threshold with CPT (ICC: 0.49, CV: 63.6%) and the cuff pressure pain threshold with CPT (ICC: 0.44, CV: 107.6%). Significant CPM effects were found for all combinations, except the combinations of electrical and heat pain thresholds with cuff CS, which indicates the novel classification of the CPM mechanism. The combinations of handheld pressure and heat pain threshold with CPT would provide the minimum sample size to detect the significant CPM changes in further studies. It is beneficial to provide and compare both ICC and CV to design further clinical trials.

1 January 2003 in Brain Research
Verified
Journal Article
Closed access
HYHao-Jun You
Hao-Jun You
CMCarsten Dahl Morch
Carsten Dahl Morch
JCJun Chen
Jun Chen
LALars Arendt-Nielsen
Lars Arendt-Nielsen

5 January 2011 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
CMCarsten Dahl Mørch
Carsten Dahl Mørch
KHKristian Hennings
Kristian Hennings
OAOle Kæseler Andersen
Ole Kæseler Andersen

3 July 2007 in European Journal of Neuroscience
Verified
Journal Article
Closed access
PDF file
CMC. D. Mørch
C. D. Mørch
JHJ. W. Hu
J. W. Hu
LALars Arendt-Nielsen
Lars Arendt-Nielsen
BSB. J. Sessle
B. J. Sessle

20 June 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JMJosé A. Biurrun Manresa
José A. Biurrun Manresa
RFRaphael Fritsche
Raphael Fritsche
PVPascal H. Vuilleumier
Pascal H. Vuilleumier
COCarmen Oehler
Carmen Oehler
CMCarsten D. Mørch
Carsten D. Mørch
MCMichele Curatolo
Michele Curatolo
The aim of this study was to determine the reliability of the conditioned pain modulation (CPM) paradigm assessed by an objective electrophysiological method, the nociceptive withdrawal reflex (NWR), and psychophysical measures, using hypothetical sample sizes for future studies as analytical goals. Thirty-four healthy volunteers participated in two identical experimental sessions, separated by 1 to 3 weeks. In each session, the cold pressor test (CPT) was used to induce CPM, and the NWR thresholds, electrical pain detection thresholds and pain intensity ratings after suprathreshold electrical stimulation were assessed before and during CPT. CPM was consistently detected by all methods, and the electrophysiological measures did not introduce additional variation to the assessment. In particular, 99% of the trials resulted in higher NWR thresholds during CPT, with an average increase of 3.4 mA (p<0.001). Similarly, 96% of the trials resulted in higher electrical pain detection thresholds during CPT, with an average increase of 2.2 mA (p<0.001). Pain intensity ratings after suprathreshold electrical stimulation were reduced during CPT in 84% of the trials, displaying an average decrease of 1.5 points in a numeric rating scale (p<0.001). Under these experimental conditions, CPM reliability was acceptable for all assessment methods in terms of sample sizes for potential experiments. The presented results are encouraging with regards to the use of the CPM as an assessment tool in experimental and clinical pain. Clinical Trials.gov NCT01636440

9 January 2011 in European journal of pain
Verified
Journal Article
Closed access
PDF file
SFSara Finocchietti
Sara Finocchietti
MNMogens Nielsen
Mogens Nielsen
CMCarsten Dahl Mørch
Carsten Dahl Mørch
LALars Arendt-Nielsen
Lars Arendt-Nielsen
TGThomas Graven-Nielsen
Thomas Graven-Nielsen