25 December 2019 in IEEE Access
The gradual fossil fuel depletion, the exponential increase in load, the environmental, social and political concern has lead to the gradual sprawl of distributed energy resources in the form of microgrid. But disproportionate integration of DERs into the conventional power system may result in the anomalous system behavior causing violation of operational limits i.e., under and overvoltage, thermal overloading, line losses, transformer or feeder overloading, harmonic distortion breaching the standards, mal-operation of the protective devices etc. The key to mitigate these violations is appropriate hosting capacity assessment. This paper proposes the concept of customary hosting capacity and enhanced hosting capacity at all nodes in a network with low voltage level, high voltage level, ampacity and total harmonic distortion as the governing criteria. The analysis is tested on reconfigured IEEE 33 bus distribution system, whose reconfiguration is achieved by particle swarm optimization, keeping loss minimization as the objective function. The attainment of enhanced hosting capacity is significant since it may lead to considerable improvement of voltage in the network, maintaining the line current values very low. The experimentation on reconfigured and base configuration of IEEE 33 bus distribution system is performed in MATLAB and validated in hardware in loop. The results are also compared with existing literature to prove its efficacy.
3 August 2023 in Electric Power Systems Research
1 December 2022 in Electric Power Systems Research
19 June 2021 in International Transactions on Electrical Energy Systems
The gradual sprawl of power system toward smart grid and enhanced integration of distributed energy resources at the distribution end is transforming the conventional distribution system and is eventually making it self-sustained. The distribution system is thus continuously evolving to prepare itself for any unforeseen natural, man-made, and complex events. These events may impact the distribution system as high-impact low-frequency (HILF) scenarios. The high intensity and widespread damage of the power system due to HILF scenarios necessitate resilience. Resilience analysis aims to identify these region-specific vulnerabilities of the electricity network and implement appropriate methods to quickly restore the system to its predisturbance state. Further to enhance the network visibility and situational awareness, integration of synchrophasor to resilience is significant. Therefore, synchrophasor technology integrated with resilience provides online wide area visibility of the distribution system. Using synchrophasor for resilience assessment propels an agile network for coordinating accurate and timely analysis of the system parameters. Therefore, understanding the concept of resilience, its evolution, detailed overview, synchrophasor-based resilience (SBR) methods as well as its applications are necessary. This article outlines the key points of the synchrophasor technology based resilience technique, its significance, and lays a foundation for continuing research in this area. It offers detailed insight into the comprehensive review of this evolving concept. The article majorly focuses on all the aspects of SBR, its necessity in performance evaluation, synchrophasor measurement based resilience enhancement methods, and application of different SBR techniques in the distribution system. A detailed comparative analysis of SBR features, sample efficiency, result accuracy, merits, and demerits based on available literature is provided. Finally, future perspectives are discussed for implementing resilience assessment using synchrophasor technology in the distribution system.
1 April 2024 in IEEE Access
Renewable distributed energy resources are the solution to rising power demand, but their integration is a difficult technological undertaking that requires careful planning. Distributed energy resources are mostly incorporated in the final level of power system networks, where harmonic content swings are highest. At the planning stage, the highest potential power injection, i.e., hosting capacity, is estimated while taking into account the main anticipated operational challenges, one of which is undesirable harmonics. But it is not possible to include all operational harmonic orders precisely for accurate hosting capacity estimation. The presence of harmonics affects the hosting capacity of the network to a considerable extent. In this work, operational derated hosting capacity is proposed to enhance the situational awareness for calculating the change in hosting capacity of the network due to the presence of operational dominant harmonics, as compared to the ideal condition. Additionally, the effect of harmonics on the power factor of the network nodes are also investigated thoroughly, abiding the limits of IEEE-519-2014. Because in any distribution network, unbalance cannot be neglected, operational derated hosting capacity is also extended for testing unbalanced conditions within the network. To justify the effectiveness of the proposed work operational derated hosting capacity is compared with the existing literature. A reconfigured IEEE-33 bus distribution network is considered for assessment. The authors utilized MATLAB along with Typhoon HIL real-time platform for modeling as well as for validation of the results.
27 June 2014 in Proceedings of the Institution of Mechanical Engineers, Part O: Journal of Risk and Reliability
Failure frequency and steady-state availability are two key indices for reliability analysis of phasor measurement units. Phasor measurement unit is the edifice of wide area measurement system and thus reliable operation is essential. Markov model is the general basis for evaluation of reliability indices, but it involves matrices of large dimension. This article describes the general purpose graphical approach for obtaining the two key reliability indices of phasor measurement units from flow graph based on Markov model. It is concerned with the calculation of availability, frequency and outage duration of phasor measurement units by module wise reliability analysis. This method itself is sufficient for sensitivity analysis of phasor measurement unit and helps in identifying the critical module within the phasor measurement unit.