10 May 2010 in physica status solidi (c)
1 June 2021 in AIP Advances
The outbreak of the coronavirus disease (COVID-19) pandemic has become a worldwide health catastrophe instigated by Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2). Countries are battling to slow the spread of this virus by testing and treating patients, along with other measures such as prohibiting large gatherings, maintaining social distance, and frequent, thorough hand washing, as no vaccines or medicines are available that could effectively treat infected people for different types of SARS-CoV-2 variants. However, the testing procedure to detect this virus is lengthy. This study proposes a surface plasmon resonance-based biosensor for fast detection of SARS-CoV-2. The sensor employs a multilayered configuration consisting of TiO2–Ag–MoSe2 graphene with a BK7 prism. Antigen–antibody interaction was considered the principle for this virus detection. Immobilized CR3022 antibody molecules for detecting SARS-CoV-2 antigens (S-glycoprotein) are used for this sensor. It was found that the proposed sensor’s sensitivity (194°/RIU), quality factor (54.0390 RIU−1), and detection accuracy (0.2702) outperformed those of other single and multilayered structures. This study could be used as a theoretical base and primary step in constructing an actual sensor.
1 March 2020 in Results in Physics
1 February 2013 in Journal of Materials Science & Technology
11 August 2021 in IEEE Access
In this era of technological advancement, the flow of an enormous amount of information has become such an inevitable phenomenon that makes a path for the takeover of the internet of things (IoT) based smart grid from the currently available grid system. In a smart grid, demand-side management plays a crucial role in reducing the generation capacity by shifting the user energy consumption from peak period to off-peak period, which requires detailed knowledge of the user consumption at the individual appliance level. Non-intrusive load monitoring (NILM) provides an exceptionally low-cost solution for determining individual appliance levels using a single-point measurement. This paper proposed an IoT-based real-time non-intrusive load classification (RT-NILC) system considering the variability of supply voltage using low-frequency data. Due to the unavailability of smart meters at the household level in Bangladesh, a data-acquisition system (DAS) is developed. The DAS is capable of measuring and storing rms voltage, rms current, active power, and power factor data at a sampling rate of 1 Hz. These data are processed to train different multilabel classification models. The best-performed classification model has been selected and utilized for the implementation of RT-NILC over IoT. The Firebase real-time online database is considered for data storage to flow the data in two-way between end-user and service provider (energy distributor). The GPRS module is used for wireless data transmission as a Wi-Fi network may not be available everywhere. Windows and web applications are developed for data visualization. The proposed system has been validated in real-time, using rms voltage, rms current, and active power measurements at a real house. Even under supply voltage variability, the performance evaluation of the RT-NILC system has shown an average classification accuracy of more than 94%. Good classification accuracy and the overall operation of the IoT-based information exchange systems ensure the proposed system’s applicability for efficient energy management.
9 November 2020 in IEEE Access
Novel GaN-based van der Walls (vdW) hetero-bilayer (HBL) is systemically studied through the first-principles density functional theory (DFT) framework to explore its optoelectronic property facilitated photocatalytic activity for hydrogen (H2) fuel production. The vdW concept of planar GaN with GeC monolayer, together making stacked hetero-bilayer, shows unique and tunable optoelectronic properties that fulfill all the photocatalysis attributes. The confirmation of chemical and dynamical stabilities is made with negative interlayer binding energy and non-negative frequency in phonon spectra, respectively. Among the dynamically stable hetero-bilayers, binding energy in HBL 2 (AB1) is the lowest and interlayer distance ~2.954 Å is the smallest. The HBLs are sensitive to the stacking arrangements, where HBL 2 demonstrates type-I direct bandgap and HBL 6 (AB6) is Type-II direct bandgap. The intrinsic HBLs show superior carrier mobility as their effective masses are lower from their constituent monolayers. Also, the intrinsic absorption coefficient of the HBLs increase as high as ~106 cm-1, 10 times greater than conventional perovskite materials, which show outperforming optoelectronic conversion efficiency. Additionally, the HBLs are highly tunable in both bandgap and type due to biaxial strains and cross-plane electric fields. With biaxial strains, from compressive to tensile, both HBLs show monotonous bandgap lowering with a dominant direct-indirect bandgap splitting in HBL 2. Interestingly, for all the biaxial strains within the -6% to +6% range, both HBLs have sufficient kinetic overpotential for photocatalytic water splitting and an increase in visible peak by 3.5 (2) times in the HBL 6 (HBL 2). Electric fields also increase the photocatalytic water splitting performance with a net bandgap lowering and increasing the visible absorption peak by ~1.5 times compared with intrinsic HBLs. These promising properties that we have found in the planar GaN/GeC vdW hetero-bilayer are highly suggestive for the impending use of this material in photocatalytic water splitting technology to produce H2 fuel.