Gijsbert Patijn

Gijsbert Patijn

Auto-generated profile, based on publicly available information

Gijsbert Patijn

Connected Care Center Isala Zwolle Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in Journal of Medical Internet Research
Verified
Journal Article
Open access
JLJobbe P L Leenen
Jobbe P L Leenen
CLCrista Leerentveld
Crista Leerentveld
JDJoris D van Dijk
Joris D van Dijk
HWHenderik L. van Westreenen
Henderik L. van Westreenen
LSLisette Schoonhoven
Lisette Schoonhoven
GPGijsbert A Patijn
Gijsbert A Patijn
Background: Continuous monitoring of vital signs by using wearable wireless devices may allow for timely detection of clinical deterioration in patients in general wards in comparison to detection by standard intermittent vital signs measurements. A large number of studies on many different wearable devices have been reported in recent years, but a systematic review is not yet available to date. Objective: The aim of this study was to provide a systematic review for health care professionals regarding the current evidence about the validation, feasibility, clinical outcomes, and costs of wearable wireless devices for continuous monitoring of vital signs. Methods: A systematic and comprehensive search was performed using PubMed/MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials from January 2009 to September 2019 for studies that evaluated wearable wireless devices for continuous monitoring of vital signs in adults. Outcomes were structured by validation, feasibility, clinical outcomes, and costs. Risk of bias was determined by using the Mixed Methods Appraisal Tool, quality assessment of diagnostic accuracy studies 2nd edition, or quality of health economic studies tool. Results: In this review, 27 studies evaluating 13 different wearable wireless devices were included. These studies predominantly evaluated the validation or the feasibility outcomes of these devices. Only a few studies reported the clinical outcomes with these devices and they did not report a significantly better clinical outcome than the standard tools used for measuring vital signs. Cost outcomes were not reported in any study. The quality of the included studies was predominantly rated as low or moderate. Conclusions: Wearable wireless continuous monitoring devices are mostly still in the clinical validation and feasibility testing phases. To date, there are no high quality large well-controlled studies of wearable wireless devices available that show a significant clinical benefit or cost-effectiveness. Such studies are needed to help health care professionals and administrators in their decision making regarding implementation of these devices on a large scale in clinical practice or in-home monitoring.

4 May 2023 in JMIR Nursing
Verified
Journal Article
Open access
JLJobbe P L Leenen
Jobbe P L Leenen
HRHenriëtte J M Rasing
Henriëtte J M Rasing
CKCor J Kalkman
Cor J Kalkman
LSLisette Schoonhoven
Lisette Schoonhoven
GPGijsbert A Patijn
Gijsbert A Patijn
Background: Continuous monitoring of vital signs (CMVS) using wearable wireless sensors is increasingly available to patients in general wards and can improve outcomes and reduce nurse workload. To assess the potential impact of such systems, successful implementation is important. We developed a CMVS intervention and implementation strategy and evaluated its success in 2 general wards. Objective: We aimed to assess and compare intervention fidelity in 2 wards (internal medicine and general surgery) of a large teaching hospital. Methods: A mixed methods sequential explanatory design was used. After thorough training and preparation, CMVS was implemented—in parallel with the standard intermittent manual measurements—and executed for 6 months in each ward. Heart rate and respiratory rate were measured using a chest-worn wearable sensor, and vital sign trends were visualized on a digital platform. Trends were routinely assessed and reported each nursing shift without automated alarms. The primary outcome was intervention fidelity, defined as the proportion of written reports and related nurse activities in case of deviating trends comparing early (months 1-2), mid- (months 3-4), and late (months 5-6) implementation periods. Explanatory interviews with nurses were conducted. Results: The implementation strategy was executed as planned. A total of 358 patients were included, resulting in 45,113 monitored hours during 6142 nurse shifts. In total, 10.3% (37/358) of the sensors were replaced prematurely because of technical failure. Mean intervention fidelity was 70.7% (SD 20.4%) and higher in the surgical ward (73.6%, SD 18.1% vs 64.1%, SD 23.7%; P<.001). Fidelity decreased over the implementation period in the internal medicine ward (76%, 57%, and 48% at early, mid-, and late implementation, respectively; P<.001) but not significantly in the surgical ward (76% at early implementation vs 74% at midimplementation [P=.56] vs 70.7% at late implementation [P=.07]). No nursing activities were needed based on vital sign trends for 68.7% (246/358) of the patients. In 174 reports of 31.3% (112/358) of the patients, observed deviating trends led to 101 additional bedside assessments of patients and 73 consultations by physicians. The main themes that emerged during interviews (n=21) included the relative priority of CMVS in nurse work, the importance of nursing assessment, the relatively limited perceived benefits for patient care, and experienced mediocre usability of the technology. Conclusions: We successfully implemented a system for CMVS at scale in 2 hospital wards, but our results show that intervention fidelity decreased over time, more in the internal medicine ward than in the surgical ward. This decrease appeared to depend on multiple ward-specific factors. Nurses’ perceptions regarding the value and benefits of the intervention varied. Implications for optimal implementation of CMVS include engaging nurses early, seamless integration into electronic health records, and sophisticated decision support tools for vital sign trend interpretation.

5 May 2023 in JMIR Perioperative Medicine
Verified
Journal Article
Open access
JLJobbe P L Leenen
Jobbe P L Leenen
VAVera Ardesch
Vera Ardesch
GPGijsbert Patijn
Gijsbert Patijn
Background: Hospital stays after colorectal surgery are increasingly being reduced by enhanced recovery and early discharge protocols. As a result, postoperative complications may frequently manifest after discharge in the home setting, potentially leading to emergency room presentations and readmissions. Virtual care interventions after hospital discharge may capture clinical deterioration at an early stage and hold promise for the prevention of readmissions and overall better outcomes. Recent technological advances have enabled continuous vital sign monitoring by wearable wireless sensor devices. However, the potential of these devices for virtual care interventions for patients discharged after colorectal surgery is currently unknown. Objective: We aimed to determine the feasibility of a virtual care intervention consisting of continuous vital sign monitoring with wearable wireless sensors and teleconsultations for patients discharged after colorectal surgery. Methods: In a single-center observational cohort study, patients were monitored at home for 5 consecutive days after discharge. Daily vital sign trend assessments and telephone consultations were performed by a remote patient-monitoring department. Intervention performance was evaluated by analyzing vital sign trend assessments and telephone consultation reports. Outcomes were categorized as “no concern,” “slight concern,” or “serious concern.” Serious concern prompted contact with the surgeon on call. In addition, the quality of the vital sign data was determined, and the patient experience was evaluated. Results: Among 21 patients who participated in this study, 104 of 105 (99%) measurements of vital sign trends were successful. Of these 104 vital sign trend assessments, 68% (n=71) did not raise any concern, 16% (n=17) were unable to be assessed because of data loss, and none led to contacting the surgeon. Of 62 of 63 (98%) successfully performed telephone consultations, 53 (86%) did not raise any concerns and only 1 resulted in contacting the surgeon. A 68% agreement was found between vital sign trend assessments and telephone consultations. Overall completeness of the 2347 hours of vital sign trend data was 46.3% (range 5%-100%). Patient satisfaction score was 8 (IQR 7-9) of 10. Conclusions: A home monitoring intervention of patients discharged after colorectal surgery was found to be feasible, given its high performance and high patient acceptability. However, the intervention design needs further optimization before the true value of remote monitoring for early discharge protocols, prevention of readmissions, and overall patient outcomes can be adequately determined.

25 February 2025 in JMIR Perioperative Medicine
Verified
Journal Article
Open access
ATA Daniëlle Talen
A Daniëlle Talen
JLJobbe P L Leenen
Jobbe P L Leenen
GSGeert van der Sluis
Geert van der Sluis
HOHilbrand Klaas Evert Oldenhuis
Hilbrand Klaas Evert Oldenhuis
JKJoost M. Klaase
Joost M. Klaase
GPGijsbert A Patijn
Gijsbert A Patijn
Background: The mainstay of colorectal cancer care is surgical resection, which carries a significant risk of complications. Efforts to improve outcomes have recently focused on intensive multimodal prehabilitation programs to better prepare patients for surgery, which make the perioperative process even more complex and demanding for patients. Digital applications (eCoaches) seem promising tools to guide patients during their care journey. We developed a comprehensive eCoach to support, guide, and monitor patients undergoing elective colorectal surgery through the perioperative phase of the care pathway. Objective: The primary aim of this study was to determine its feasibility, in terms of recruitment rate, retention rate, and compliance. Also, usability and patient experience were examined. Methods: A single-center cohort study was conducted from April to September 2023 in a tertiary teaching hospital in the Netherlands. All elective colorectal surgery patients were offered an eCoach that provided preoperative coaching of the prehabilitation protocol, guidance by giving timely information, and remote monitoring of postoperative recovery and complications. Recruitment and retention rate, as well as compliance for each part of the care pathway, were determined. Secondary, patient-reported usability measured by the Usefulness, Satisfaction, and Ease of Use questionnaire and patient experiences were reported. Results: The recruitment rate for the eCoach was 74% (49/66). Main reasons for exclusion were digital illiteracy (n=10), not owning a smartphone (n=3), and the expected burden of use being too high (n=2). The retention rate was 80% (37/46). Median preoperative compliance with required actions in the app was 92% (IQR 87-95), and postoperative compliance was 100% (IQR 100-100). Patient-reported usability was good and patient experiences were mostly positive, although several suggestions for improvement were reported. Conclusions: Our results demonstrate the feasibility of a comprehensive eCoach for guiding and monitoring patients undergoing colorectal surgery encompassing the entire perioperative pathway, including prehabilitation and postdischarge monitoring. Compliance was excellent for all phases of the care pathway and recruitment and retention rates were comparable with rates reported in the literature. The study findings provide valuable insights for the further development of the eCoach and highlight the potential of digital health applications in perioperative support.

9 March 2020 in JMIR Preprints
Verified
Preprint
Open access
JLJobbe Pl Leenen
Jobbe Pl Leenen
CLCrista Leerentveld
Crista Leerentveld
JDJoris D van Dijk
Joris D van Dijk
HWHenderik L. van Westreenen
Henderik L. van Westreenen
LSLisette Schoonhoven
Lisette Schoonhoven
GPGijsbert A Patijn
Gijsbert A Patijn
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Continuous monitoring of vital signs by using wearable wireless devices may allow for timely detection of clinical deterioration in patients in general wards in comparison to detection by standard intermittent vital signs measurements. A large number of studies on many different wearable devices have been reported in recent years, but a systematic review is not yet available to date. Objective: The aim of this study was to provide a systematic review for health care professionals regarding the current evidence about the validation, feasibility, clinical outcomes, and costs of wearable wireless devices for continuous monitoring of vital signs. Methods: A systematic and comprehensive search was performed using PubMed/MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials from January 2009 to September 2019 for studies that evaluated wearable wireless devices for continuous monitoring of vital signs in adults. Outcomes were structured by validation, feasibility, clinical outcomes, and costs. Risk of bias was determined by using the Mixed Methods Appraisal Tool, quality assessment of diagnostic accuracy studies 2nd edition, or quality of health economic studies tool. Results: In this review, 27 studies evaluating 13 different wearable wireless devices were included. These studies predominantly evaluated the validation or the feasibility outcomes of these devices. Only a few studies reported the clinical outcomes with these devices and they did not report a significantly better clinical outcome than the standard tools used for measuring vital signs. Cost outcomes were not reported in any study. The quality of the included studies was predominantly rated as low or moderate. Conclusions: Wearable wireless continuous monitoring devices are mostly still in the clinical validation and feasibility testing phases. To date, there are no high quality large well-controlled studies of wearable wireless devices available that show a significant clinical benefit or cost-effectiveness. Such studies are needed to help health care professionals and administrators in their decision making regarding implementation of these devices on a large scale in clinical practice or in-home monitoring.

23 November 2022 in JMIR Preprints
Verified
Preprint
Open access
JLJobbe P L Leenen
Jobbe P L Leenen
HRHenriëtte J M Rasing
Henriëtte J M Rasing
CKCor J Kalkman
Cor J Kalkman
LSLisette Schoonhoven
Lisette Schoonhoven
GPGijsbert A Patijn
Gijsbert A Patijn
BACKGROUND Continuous monitoring of vital signs (CMVS) using wearable wireless sensors is increasingly available to patients in general wards and can improve outcomes and reduce nurse workload. To assess the potential impact of such systems, successful implementation is important. We developed a CMVS intervention and implementation strategy and evaluated its success in 2 general wards. OBJECTIVE We aimed to assess and compare intervention fidelity in 2 wards (internal medicine and general surgery) of a large teaching hospital. METHODS A mixed methods sequential explanatory design was used. After thorough training and preparation, CMVS was implemented—in parallel with the standard intermittent manual measurements—and executed for 6 months in each ward. Heart rate and respiratory rate were measured using a chest-worn wearable sensor, and vital sign trends were visualized on a digital platform. Trends were routinely assessed and reported each nursing shift without automated alarms. The primary outcome was intervention fidelity, defined as the proportion of written reports and related nurse activities in case of deviating trends comparing early (months 1-2), mid- (months 3-4), and late (months 5-6) implementation periods. Explanatory interviews with nurses were conducted. RESULTS The implementation strategy was executed as planned. A total of 358 patients were included, resulting in 45,113 monitored hours during 6142 nurse shifts. In total, 10.3% (37/358) of the sensors were replaced prematurely because of technical failure. Mean intervention fidelity was 70.7% (SD 20.4%) and higher in the surgical ward (73.6%, SD 18.1% vs 64.1%, SD 23.7%; P<.001). Fidelity decreased over the implementation period in the internal medicine ward (76%, 57%, and 48% at early, mid-, and late implementation, respectively; P<.001) but not significantly in the surgical ward (76% at early implementation vs 74% at midimplementation [P=.56] vs 70.7% at late implementation [P=.07]). No nursing activities were needed based on vital sign trends for 68.7% (246/358) of the patients. In 174 reports of 31.3% (112/358) of the patients, observed deviating trends led to 101 additional bedside assessments of patients and 73 consultations by physicians. The main themes that emerged during interviews (n=21) included the relative priority of CMVS in nurse work, the importance of nursing assessment, the relatively limited perceived benefits for patient care, and experienced mediocre usability of the technology. CONCLUSIONS We successfully implemented a system for CMVS at scale in 2 hospital wards, but our results show that intervention fidelity decreased over time, more in the internal medicine ward than in the surgical ward. This decrease appeared to depend on multiple ward-specific factors. Nurses’ perceptions regarding the value and benefits of the intervention varied. Implications for optimal implementation of CMVS include engaging nurses early, seamless integration into electronic health records, and sophisticated decision support tools for vital sign trend interpretation.