15 November 2023 in IEEE Letters on Electromagnetic Compatibility Practice and Applications
Open transverse electromagnetic (TEM) cells are used for many applications. Usually, such cells are built of metal sheets with linear profiles. Due to these simple geometries, the impedance matching is limited. To improve the matching, a simple semi-analytical method for an advanced septum profile is developed. Dominant TEM-mode propagation and an expression for the characteristic impedance of a stripline are considered. The characteristic impedances of the feed and the central stripline are equal to a given, desired value. To minimize reflections, the characteristic impedance of the TEM mode is enforced to be constant over the entire structure, especially along the tapered sections. In this way the proposed method returns the septum width as a function of the longitudinal coordinate along the cell such that each cross-section has a characteristic impedance equal to the given, desired value. A septum designed according to the proposed method is manufactured and installed in a TEM cell prototype. The 30 MHz -1 GHz frequency range is considered to cover CISPR bands C and D. Both measurements and full-wave simulations indicate an improvement in the return loss of 4.6 dB from 10.6 dB to 15.2 dB with respect to the previously installed linearly tapered septum.
3 October 2023 in IEEE Transactions on Electromagnetic Compatibility
In this article, a compliant radiated emission setup based on a low-cost software-defined radio (SDR) and a transverse electromagnetic cell is presented. The SDR B200mini from Ettus Research is investigated, which incorporates the popular Analog Devices AD9364 transceiver chip. The most demanding requirements for receivers are specified in CISPR band C/D. Therefore, the focus is put on the respective frequency range 30 MHz–1 GHz. For performance verification, test signals specified in the dedicated norm CISPR 16-1-1 are utilized. The results show that the B200mini is capable to measure broadband impulses using the peak detector at an analysis bandwidth of 20 MHz. However, downconversion spurs hinder accurate measurements at low tuning frequencies. To overcome this, a highly linear upconversion stage is presented, offering sufficient dynamic range for quasi-peak detector measurements, which are the benchmark for professional receivers. Owing to the bandpass-filtered output of the stage, the SDR must fulfill less stringent linearity requirements, and downconversion spurs become a minor issue. Combining the SDR with the upconversion stage allows one to use full-scale resolution of the implemented analog-to-digital converters (ADCs) without driving the SDR's analog front end into saturation. By decreasing the bandwidth of the ADC's antialiasing filters to 1 MHz, it becomes possible to fulfill quasi-peak detector requirements. Supplementary to CISPR 16-1-1 , the overall system performance is verified by characterizing a test device. It is shown that the results are comparable with accredited electromagnetic compatibility test houses, enabling a reliable estimate of radiated emission spectra.
7 December 2022 in IEEE Letters on Electromagnetic Compatibility Practice and Applications
In this paper, a highly linear frontend to improve the performance of (software-defined radios) SDRs for radiated precompliance measurements is presented. In CISPR band C/D, the test receiver needs to fulfill stringent requirements for using the quasi-peak detector. Usually, an expensive preselection filter bank is necessary to make fully compliant measurements of broadband transients. Direct-conversion based SDRs show a limited out-ofthe-box performance for pre-compliance measurements caused by, e.g., harmonic mixing and saturation effects. With the use of a triple-balanced mixer, a highly linear up-conversion stage is built, eliminating the need for a filter bank. The dynamic range requirements for the SDR are strongly reduced by a narrowband intermediate frequency filter, making CISPR 16-1-1 compliant measurements possible. The sensitivity of the frontend is comparable to professional receivers on the market, although no low-noise amplifier is implemented. The performance is verified by continuous wave and transient signals according to CISPR norms. The broadband measurement results are compared with traditional characterizations of the dynamic range using the compression level and the noise figure. It shows that assumptions on the RF-link budget for a compliant design can be made with continuous wave measurements. Based on our results, the requirements for the SDR frontend are derived.
17 March 2026 in IEEE Letters on Electromagnetic Compatibility Practice and Applications
This paper presents an improved open transverse electromagnetic (TEM) cell for pre-compliance testing. The design shows a 300 mm septum height and works over CISPR Bands C and D (from 30 MHz to 1 GHz). The improvement lies in its do-it-yourself construction, enabling in-house manufacturing using laser-cut, bendable sheet metals with rectangular slots removed to ease bending. The resulting structure is cost-effective and mechanically robust. 3D-printed supports extending only between the septum and the upper conductor improve the accessibility to the test volume. The design is tested experimentally (minimum return loss of 11.5 dB), and its reproducibility is validated over four independently assembled samples.