23 March 2023 in Journal of the Mechanical Behavior of Biomedical Materials
1 January 2023 in Vojnosanitetski Pregled
1 January 2020 in Srpski arhiv za celokupno lekarstvo
Introduction/Objective. The objective of this study is to use scanning electron microscopy (SEM) to analyze working surfaces of new manual and rotary endodontic instruments and to check possible existence of manufacture dirt particles or defects on the working surface. Methods. In this study, we used three sets of new manual instruments: K-File, KF (Dentsply Maillefer, Switzerland) and Hedstorm Files, HF (SybronEndo Co, USA) and three sets of mechanical Ni-Ti instruments ? type K3 (SybronEndo Co, USA) and BioRaCe (FKG DENTAIRE Swiss Dental Products, Switzerland). The instruments were analyzed using SEM method at 170 ? magnification while semi-quantitative energy dispersive x-ray analysis was used to determine chemical composition of dirt particles. Fisher test (p < 0.05) was applied in statistical analysis. Results. Results showed that none of the instruments were defect-free. The most common defect type was the presence of metal strips, which were noticed at the surface of all tested instruments. Debris was present on all manual and only one type of mechanical instruments, K3 (39% in the apical and 33% in the middle third). Fretting was noticed in all manual KF and all mechanical instruments of the K3 group. Pitting was common in all manual instruments, KF (33% in the apical and 39% in the middle third) and HF (11% in the apical and 6% in the middle third). Corrosion of the working surface, metal flash, and disruption of the cutting edge were marked only in the KF group. Conclusion. Manufacture defects were noticed in all instruments and the most common type of irregularity were metal strips. Electropolished surface of BioRaCe instruments showed no debris of organic origin.
1 January 2022 in Vojnosanitetski Pregled
The introduction of NiTi rotary files into endodontic practice is one of the biggest steps towards more successful and better canal treatment. New perspectives in endodontics have been opened, thanks primarily to the extreme flexibility and the feature of smart materials to be able to return to their original shape after deformation. New concepts of making these files in recent years include the introduction of new alloys to improve their features, ie a new specific design of the workpiece that provides efficient cutting and elimination of dentin with a significant reduction in stress and possible complications during hemomechanical processing of canals. The introduction of new alloys for the manufacture of files and their exposure to special thermal treatment has affected their superior features, greater flexibility and increased resistance to cyclic fatigue. The concept of single-file treatment includes various systems that use full rotation, reciprocal movements (or a combination thereof), or systems with eccentric and transaxial movements to increase cutting efficiency and reduce cyclic file fatigue. The new movements of the files also offer greater safety and efficiency because they significantly reduce the contact of the files with the walls and thus the stress during the preparation of the canal. The preparation of the canal with only one file is based on the concept of "less is more" and has fundamentally changed a lot in endodontics (conceptually, procedurally and economically), and made endodontic intervention simpler, faster and more certain. This significantly shortens the duration of endodontic intervention, eliminates the possibility of cross-contamination and significantly saves time and financial expenses for both patients and endodontists. Understanding the design of new NiTi files and the correct choice of movement dynamics during chemomechanical processing allows the practitioner to maximize his endodontic skill in each endodontic technique, to increase the efficiency of the intervention and significantly minimize the possibility of error. The aim of this paper is to present a perspective concept of single-file treatment, to present the development and strategies of different systems of single NiTi files and to present the indications and the possibility of their application in different clinical situations.
1 January 2023 in Vojnosanitetski Pregled
Background/Aim. There is no standard protocol for cleaning and disinfection of used endodontic instruments before their sterilization and reuse. The aim of this study was to determine the efficiency of the different methods of removing biological debris from different types of used hand stainless steel endodontic instruments. Methods. A total of 120 hand stainless steel endodontic instruments: KerrTM reamers, KerrTM files, and Hedstr?mTM files, each forty ISO 25, used for root canal treatment on extracted teeth, were analyzed. The used instruments were divided into four groups based on different decontamination protocols. The evaluation of the efficiency of the cleaning methods was based on the evaluation of the amount of stained organic residues on the instruments (Van Gieson staining). Samples were analyzed by stereomicroscopy (x40). Statistical analysis was performed using the Mann-Whitney U test for the KerrTM reamers and Hedstr?mTM files, while the One-Way ANOVA/Bonferroni test was used for the KerrTM files, at a significance level of 5 % ( ? = 0 .05). Results. Residual biological debris was observed on 93.3% of all the samples taken. The thermal disinfectant cleaning method showed the lowest contamination values for all types of instruments. The method of mechanical cleaning showed that the mean value of maximum biologic contamination (MBC) was 58.5% for the KerrTM reamers and 56.2% for KerrTM files, while for Hedstr?mTM files, the highest MBC (50.2%) was shown by the ultrasonic method of cleaning. Conclusion. The use of a thermal disinfectant was the most efficient cleaning method for all three types of hand endodontic instruments.
1 January 2021 in Stomatoloski glasnik Srbije
Introduction. Modern endodontic procedure implies the use of rotary Ni-Ti instruments during chemomechanical treatment of root canals. The aim of this study is to analyze the surfaces of new (unused) rotary endodontic instruments using the SEM-EDS method and determine how frequently manufacture defects or impurities appear on their working surfaces. Material and method. Five new different sets of rotary endodontic Ni-Ti instruments were included in this study: K3, Mtwo, ProTaper Universal, HyFlex and BioRaCe. The working part of endodontic instrument was analyzed using SEMEDS method (magnifications ?150 to ?2000), which determined the morphological characteristics of the instrument surface and chemical composition of the found impurities. Statistical analysis was performed using the Fisher?s test (p < 0.05). Results. The results of SEM-EDS analysis showed that there is no new instrument without defects on its surface. The most common defects were observed in K3 (27.43%) and ProTaper Universal group (27.21%) and the least were in BioRaCe instruments (7.67%). The most common type of defect in tested instruments was fretting. In addition, the presence of debris and metal strips was found on all instruments, while corrosion of the working part was observed only in K3, ProTaper Universal and Mtwo systems in a small percentage. Conclusion. Based on the results of this research, it can be concluded that manufacturing defects were noticed in all examined instruments. The most common defect is pitting. Impurities such as debris and metal strips have also been registered. No organic debris was observed on electropolished surface of BioRaCe instruments, but a small percentage of other types of defects were registered.