Edmund E. Rachkovsky

Edmund E. Rachkovsky

Auto-generated profile, based on publicly available information

Edmund E. Rachkovsky

Research Institute of Clinical and Experimental Lymphology – Branch of the Institute of Cytology and Genetics of SB RAS

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2021 in Acta Biomedica Scientifica
Verified
Journal Article
Open access
PDF file
ASA. V. Shurlygina
A. V. Shurlygina
SMS. V. Michurina
S. V. Michurina
LRL. N. Rachkovskaya
L. N. Rachkovskaya
ASA. E. Serykh
A. E. Serykh
SMS. M. Miroshnichenko
S. M. Miroshnichenko
АЛА. Ю. Летягин
А. Ю. Летягин
It is known that the circadian rhythm of melatonin production depends on the intensity of illumination. Violation of the light regime leads to suppression of melatonin synthesis and the development of desynchronosis, which increases the risk of developing a number of pathologies. In this regard, it is relevant to search for opportunities to restore disturbed circadian rhythms and, especially, to correct immune dysfunctions that occur in these situations.The aim of this study was to examine the effect of a complex of melatonin, aluminum oxide and polymethylsiloxane on the lymphocytes of the spleen of mice kept under round-the-clock lighting.Materials and methods. Mice of the C57Bl/6J line were kept under round-the-clock lighting for 14 days, against which they were intragastrically injected with distilled water, aluminum oxide with polydimethylsiloxane, melatonin and a complex of melatonin, aluminum oxide and polymethylsiloxane (a new drug developed by the Research Institute of Clinical and Experimental Lymphology – Branch of the Federal Research Center Institute of Cytology and Genetics SB RAS; Patent of Russian Federation No. 2577580, 2016), represented by a complex of porous material (aluminum oxide with polydimethylsiloxane) and melatonin, immobilized in the pores, from which it is gradually released in a liquid medium. Intact animals kept under the light regime of ST 12/12 and under round-the-clock lighting served as a control. Immunophenotyping of spleen B- and T-lymphocytes was performed on a flow cytofluorimeter with monoclonal antibodies APC CD3 and FITC CD19. For studying the distribution of cells by stages of the cell cycle in splenocytes, the amount of intracellular DNA was measured by the level of inclusion of propidium iodide.Results. Flow cytometry of the distribution of B- and T-lymphocytes of the spleen in male mice of the C57Bl/6J line kept under round-the-clock lighting conditions (KO 24/0 h) revealed a decrease in the percentage of B-lymphocytes and an increase in the number of T-lymphocytes, compared with animals kept under standard lighting conditions (the light/dark photoperiod – 14/10 hours). The ratio of CD19+/CD3+ lymphocytes of the spleen in mice under the conditions of KO significantly decreases (1.5 times) compared to intact animals (p ≤ 0.001). The administration of pure and modified melatonin (Complex M) to animals kept under round-the-clock lighting conditions has an equally pronounced normalizing effect on the cellular composition of B- (CD19) and T- (CD3) lymphocytes of the spleen, bringing the values of the studied parameters to the control values of the intact animals (p ≤ 0.001) Round-the-clock lighting affects the proliferative potential of splenocytes, reducing the number of cells in the G2/M phase, compared with animals treated with melatonin (p ≤ 0.050). The introduction of melatonin leads to an increase in the percentage of cells in the G2/M phase relative to the placebo group (p ≤ 0.050). In the group of mice treated with Complex M, the greatest increase in cells at the S + G2/M phases and the highest percentage of cells at the G2/M phase were revealed compared to the placebo control group (p ≤ 0.050).Conclusion. The complex of melatonin, aluminum oxide and polymethylsiloxane has additional immunotropic properties in relation to the modifier molecule, which, apparently, are due to the joint immunostimulating effect of melatonin and the lymphostimulating effect of the sorbent. Melatonin in the composition of the complex shows its properties more stably.

29 August 2024 in Siberian Scientific Medical Journal
Verified
Journal Article
Open access
PDF file
AMAndrey Momot
Andrey Momot
LRL. N. Rachkovskaya
L. N. Rachkovskaya
VNVadim Nimaev
Vadim Nimaev
ERE. E. Rachkovsky
E. E. Rachkovsky
AMA. N. Mamaev
A. N. Mamaev
ASA. A. Smagin
A. A. Smagin
Aim of the study was to evaluate the effect of lithium- and melatonin-containing sorbent based on aluminum oxide and polydimethylsiloxane on changes in the number of platelets during hemosorption modeling and on the features of the hemostatic response during dosed contact of the sorbent with blood in an in vitro experiment. Material and methods. An analysis of the effect of the porous sorbent modified with melatonin (MT, 0.15 %) and lithium (0.5 %) based on aluminum oxide and polydimethylsiloxane (Al2O3@PDMS/MT-Li) was carried out in comparison with sorbent without modifiers (Al2O3@PDMS) and modified with MT (Al2O3@PDMS/MT) on a number of donor blood clotting parameters under in vitro hemosorption conditions. Studies of the hemostatic system included assessment of platelet count, chronometric parameters, fibrinogen concentration, antithrombin activity and plasminogen content. For integral assessment, calibrated thrombography and computer thromboelastometry were used. Results and discussion. Contact of all studied sorbents with blood causes a moderate decrease in the number of platelets (by 5.3–10.1 % from initial). Comparison sorbents reduce fibrinogen concentration by 7.1–7.7 %, Al2O3@PDMS/MT-Li – by 2.6 times, which is likely due to the methodology for determining this protein against the background of the independent anticoagulant activity of lithium ions. Al2O3@PDMS and Al2O3@PDMS/MT cause the development of a hypercoagulable shift, as evidenced by a shortening of kaolin time (by 27.5 and 22.1 %, respectively) and of activated partial thromboplastin time (APTT) by 7.1 % for both sorbents. At the same time, when lithium was included in the sorbent, not only did the hypercoagulation shift not occur, but blood clotting was also inhibited, as evidenced by an increase in kaolin time and APTT by 1.2 and 1.6 times, respectively, as well as in silicone time. Conclusions. Modifying sorbents with biologically active substances, lithium and MT, makes it possible to obtain an original hemosorbent with new properties. The presented results demonstrated the absence of a hypercoagulable shift in donor blood after contact with a lithium-, MTcontaining sorbent in vitro and indicate the potential for its using as a basis for the development of safe drugs.

27 October 2022 in Siberian Scientific Medical Journal
Verified
Journal Article
Open access
PDF file
LRL. N. Rachkovskaya
L. N. Rachkovskaya
ASA. A. Smagin
A. A. Smagin
VNVadim Nimaev
Vadim Nimaev
ADA. Yu. Demura
A. Yu. Demura
ERE. E. Rachkovsky
E. E. Rachkovsky
ALA. Yu. Letyagin
A. Yu. Letyagin
The aim of the study was to investigate the influence of the original porous silver–containing sorbent on the morphofunctional parameters of red blood cells during in vitro hemoperfusion. Material and methods. Donor blood was perfused through glass columns filled with a sorbent based on porous aluminum oxide, polydimethylsiloxane and silver nanoclusters and a sorbent without silver. The effect of a silver-containing sorbent on the change in morphofunctional parameters of red blood cells after perfusion through sorbents was determined by scanning flow cytometry. Results and their discussion. Due to the uniformity of the distribution of silver (0.1 %) over the sorbent granules, the parameters of the porous structure – the specific surface area and pore volume – practically do not change compared to the sorbent without silver. Morphological parameters of original donor blood and after hemoperfusion are within the norm. The functional parameters are also normal, although the introduction of silver in to the sorbent slightly increases the number of active band 3 (B3) proteins on erythrocyte membranes, both in comparison with the donor red cell mass as a control and in comparison with the sorbent without silver. There is also an increase in the ultimate extensibility of the erythrocyte membrane compared to the original blood (2.2 times) and the sorbent without silver (1.4 times). Conclusions. A sorbent modified with silver and a sorbent without silver does not have a damaging toxic effect on the morphofunctional parameters of blood under perfusion conditions. The mechanisms affecting the indicators of the ultimate extensibility of the erythrocyte membrane after blood perfusion through a silver-containing sorbent require further research.

28 October 2021 in Siberian Scientific Medical Journal
Verified
Journal Article
Open access
PDF file
ALAlexander Lykov
Alexander Lykov
LRL. N. Rachkovskaya
L. N. Rachkovskaya
OPO. V. Poveshchenko
O. V. Poveshchenko
ERE. E. Rachkovsky
E. E. Rachkovsky
ALA. Yu. Letyagin
A. Yu. Letyagin
АЛА. Ю. Летягин
А. Ю. Летягин
A comparative study of the effect of a matrix based on porous aluminum oxide and a silicon organic polymer polydimethylsiloxane (PDMS) (А12O3@PDMS) and a matrix complex with copper and zinc sorbed on its surface (Cu@Zn- А12O3@PDMS) on the functional properties of fibroblasts has been carried out.Material and methods.The effect of the Cu@Zn- А12O3@PDMS complex and the matrix on the cell proliferative potential (MTT test), apoptosis, necrosis and the production of stable nitric oxide (NO) metabolites were studied in an in vitro experiment with a human embryo fibroblast cell line (HEF-15).Results.The compared samples of Cu@Zn-A12O3@PDMS and Al2O3@PDMS are similar in their physico-chemical properties. Study of HEF-15 functional potential indicates a higher level of cell proliferation and ability to produce NO after contact with the complex. There was no significant increase in apoptosis and necrosis of HEF-15 in the presence of samples of the complex and the carrier.Conclusion.The absence of a significant negative effect of the tested samples on the functional status of cells of the FEH-15 line (proliferation, apoptosis, necrosis, NO secretion) in vitro allows the use of the Cu@Zn-A12O3@PDMS complex for further analysis of its safety in experimental models of skin defects in animals.

7 July 2022
Verified
Conference Paper
Closed access
ALAlexander Lykov
Alexander Lykov
LRLubov Rachkovskaya
Lubov Rachkovskaya
EREdmund Rachkovsky
Edmund Rachkovsky
OPOlga Poveshchenko
Olga Poveshchenko
This work described effects of the composition of menthol, camphor, boric acid, and colloidal silver with particles of porous aluminum oxide with polydimethylsiloxane on THP-1 and U-937 cell lines in vitro. Effects of the composition on THP-1 and U-937 cells NAD (P) H-dependent oxidoreductase intracellular enzyme activity, lactate, glucose and NO levels in conditioned media were studied. It was found that composition increased NAD (P) H-dependent oxidoreductase intracellular enzyme activity, decreased lactate production, and glucose consumption by THP-1 and U-937 cells in vitro.

7 July 2022
Verified
Conference Paper
Closed access
ASAlexander Smagin
Alexander Smagin
LRLubov Rachkovskaya
Lubov Rachkovskaya
VNVadim Nimaev
Vadim Nimaev
EYEkaterina Yastrebova
Ekaterina Yastrebova
EREdmund Rachkovsky
Edmund Rachkovsky
ALAndrey Letyagin
Andrey Letyagin
As preventive, curative and restorative measures in modern conditions of the spread of infectious diseases (Covid 19), the use of sorption materials and detoxification methods with their use in hemosorption are of particular importance. It is known that hemosorption is an effective method of detoxification of the body, and no less important is the use of safe sorbents in relation to the shaped elements of blood, both time-tested sorbents and new, less studied, but more promising from the point of view of their safe production technology. The purpose of this work is to study with the help of scanning flow cytometry the effect of a sorbent with carbon nanofiber A1203@PDMS/CNF in comparison with a carbon-free sorbent A1203@PDMS on morphofunctional parameters erythrocytes. The study of the physico-chemical properties of sorbents was carried out according to standard methods. The biological properties of sorbents were evaluated by its effect on erythrocytes of erythrocyte concentrate during hemoperfusion of blood through columns with sorbents using the method of scanning flow cytometry according to the standard method. The data obtained using the method of scanning flow cytometry made it possible to conclude that the studied sorbents do not have a traumatic effect on the morphofunctional parameters of erythrocytes. The introduction of carbon nanofiber into the composition of the sorbent in an amount of 0.02% improves the functional parameters of blood erythrocytes both in comparison with the initial donor blood and compared to the sorbent without carbon.