Jesse X. Wayment

Jesse X. Wayment

Auto-generated profile, based on publicly available information

Jesse X. Wayment

Electrical and Computer Engineering Department, Brigham Young University, Provo, UT 84602

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2024 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
MSMohammad Julker Neyen Sampad
Mohammad Julker Neyen Sampad
SSS. M. Saiduzzaman
S. M. Saiduzzaman
ZWZach J. Walker
Zach J. Walker
TWTanner Wells
Tanner Wells
JWJesse X. Wayment
Jesse X. Wayment
HSHolger Schmidt
Holger Schmidt
Viral outbreaks can cause widespread disruption, creating the need for diagnostic tools that provide high performance and sample versatility at the point of use with moderate complexity. Current gold standards such as PCR and rapid antigen tests fall short in one or more of these aspects. Here, we report a label-free and amplification-free nanopore sensor platform that overcomes these challenges via direct detection and quantification of viral RNA in clinical samples from a variety of biological fluids. The assay uses an optofluidic chip that combines optical waveguides with a fluidic channel and integrates a solid-state nanopore for sensing of individual biomolecules upon translocation through the pore. High specificity and low limit of detection are ensured by capturing RNA targets on microbeads and collecting them by optical trapping at the nanopore location where targets are released and rapidly detected. We use this device for longitudinal studies of the viral load progression for Zika and Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) infections in marmoset and baboon animal models, respectively. The up to million-fold trapping-based target concentration enhancement enables amplification-free RNA quantification across the clinically relevant concentration range down to the assay limit of RT-qPCR as well as cases in which PCR failed. The assay operates across all relevant biofluids, including semen, urine, and whole blood for Zika and nasopharyngeal and throat swab, rectal swab, and bronchoalveolar lavage for SARS-CoV-2. The versatility, performance, simplicity, and potential for full microfluidic integration of the amplification-free nanopore assay points toward a unique approach to molecular diagnostics for nucleic acids, proteins, and other targets.

21 July 2026 in European Journal of Control
Verified
Journal Article
Closed access
SGSebin Gracy
Sebin Gracy
JWJesse Wayment
Jesse Wayment
IMIrinel C. Morărescu
Irinel C. Morărescu
VVVineeth S. Varma
Vineeth S. Varma
PPPhilip E. Paré
Philip E. Paré