28 June 2020 in Communication Sciences & Disorders
10 October 2021 in Journal of Audiology and Otology
Background and Objectives: This study aimed to investigate the occupational performance of Korean workers with and without hearing loss and analyze the hearing-related difficulties in the working environment.Subjects and Methods: The Amsterdam checklist for hearing and work was used for the analyses and the occupational environments of the Korean workers were investigated. Out of 129 total participants, 86 workers experienced severe to profound hearing loss and 43 had the normal hearing ability. The hearing-impaired workers were recruited from two leading vocational centers and normal-hearing workers were their colleagues.Results: The hearing-impaired workers were found to take fewer sick leaves and exhibited higher rates of permanent job statuses compared to the normal-hearing workers. Workers with hearing loss rarely detected background sound; however, they could perceive reverberation more frequently. They felt more satisfied with their careers than the normal hearing workers as they received social support and needed to put their effort into hearing for most hearing activities. Furthermore, the effort in hearing increased with the increase in job demand, job control, social support, and career satisfaction. The working hours per week increased with the increase in age, education level, job demand, job control, and social support. Different trends were observed in 9 out of 12 variables while comparing the data from the present study with that obtained from the hearing-impaired workers of the Netherlands, indicating a large difference between countries.Conclusions: Although the hearing-impaired Korean workers operate diligently with good job positions, it is necessary to enhance their acoustic environment and provide them social support. Considering the cultural background of the hearing-impaired workers, the development of suitable vocational rehabilitation programs and specific questionnaires is strongly recommended worldwide.
10 April 2022 in Journal of Audiology and Otology
Background and Objectives: Natural and synthetic speech signals effectively stimulate cortical auditory evoked potential (CAEP). This study aimed to select the speech materials for CAEP and identify CAEP waveforms according to gender of speaker (GS) and gender of listener (GL).Subjects and Methods: Two experiments including a comparison of natural and synthetic stimuli and CAEP measurement were performed of 21 young announcers and 40 young adults. Plosive /g/ and /b/ and aspirated plosive /k/ and /p/ were combined to /a/. Six bisyllables–/ga/-/ka/, /ga/-/ba/, /ga/-/pa/, /ka/-/ba/, /ka/-/pa/, and /ba/-/pa/–were formulated as tentative forwarding and backwarding orders. In the natural and synthetic stimulation mode (SM) according to GS, /ka/ and /pa/ were selected through the first experiment used for CAEP measurement.Results: The correction rate differences were largest (74%) at /ka/-/ pa/ and /pa/-/ka/; thus, they were selected as stimulation materals for CAEP measurement. The SM showed shorter latency with P2 and N1-P2 with natural stimulation and N2 with synthetic stimulation. The P2 amplitude was larger with natural stimulation. The SD showed significantly larger amplitude for P2 and N1-P2 with /pa/. The GS showed shorter latency for P2, N2, and N1-P2 and larger amplitude for N2 with female speakers. The GL showed shorter latency for N2 and N1-P2 and larger amplitude for N2 with female listeners.Conclusions: Although several variables showed significance for N2, P2, and N1-P2, P1 and N1 did not show any significance for any variables. N2 and P2 of CAEP seemed affected by endogenous factors.
31 July 2021 in Audiology and Speech Research
Purpose: The aim of this study was to compose the test for music perception and analyze the characteristic of cochlear implant users’ music perception.Methods: The test was made up with the pitch, melody, and timbre factors, using three low and high frequencies, six music genres, and four types of musical instruments correspondingly. The tests were conducted to 10 normal-hearing (NH) young adults and 10 young cochlear-implant (CI) users.Results: All the music perception tests showed significant differences between NH and CI group [F(1, 4) = 0.018, p = 0.019]. In the pitch test, CI group showed significantly lower correction rate(51.3%) than NH group (82.7%) did with higher correction rates in low frequencies. In the melody test, CI group showed significantly lower correction rate (29.7%) than NH group (95.8%) did with the highest performance in folk songs (51.7%). In the timbre test, CI group showed significantly reduced performance (22.5%) than NH group (65.8%) did. For both CI and NH groups, the pitched percussion showed the highest scores (45% and 100%) while the woodwind showed the lowest scores (13.3% and 48.3%).Conclusion: Out of three tests, CI group showed better performance in pitch perception than melody and timber perception. CI group showed better performances in low pitch sounds, melodies of familiar genre, and sound of pitched percussion instruments’ timber showing complicated music perception ability. To enhance the music perception ability for CI users by aural rehabilitation, more specified and systematic music perception test material should be developed.