29 October 2023 in Journal for ImmunoTherapy of Cancer
Background: Gut microbiota composition can influence cancer immunotherapy response. Recent evidence suggests Helicobacter pylori infection may reduce immune checkpoint inhibitor (ICI) efficacy in lung cancer and melanoma, but thorough characterization of this association in patients with gastric cancer is lacking. We aimed to determine the impact of H. pylori on survival in this population. Methods: This single-center, retrospective study included all ICI-treated individuals with metastatic gastric cancer and documented H. pylori status at Memorial Sloan Kettering between July 2013 and October 2021. H. pylori-positive status was defined as history of infection obtained via breath test, stool antigen test, histopathology, and/or chart documentation. Negative status was defined as explicitly negative testing, histopathology, and/or chart documentation. Primary outcomes were progression-free survival (PFS) and overall survival (OS). Results: Of 215 included patients, 49 had documented history of H. pylori infection. Compared with H. pylori-negative patients, positive individuals tended to be younger, non-white, and Hispanic with non-cardia and intestinal-type gastric cancer. H. pylori-positive patients had significantly shorter median PFS (3.2 vs 6.8 months, HR 1.96, p<0.01) and OS (9.8 vs 17.9 months, HR 1.54, p=0.02). Multivariable analysis confirmed H. pylori infection as an independent predictor of PFS (HR 3.04, p<0.01) and OS (HR 2.24, p=0.01). Conclusions: In this largest study of its kind, H. pylori infection was associated with inferior survival in ICI-treated patients with gastric cancer. This suggests H. pylori status may be a prognostic marker of immune responsiveness. Future studies are needed to elucidate immunoregulatory mechanisms and whether treatment of active infections would improve immunotherapy outcomes.
20 July 2024 in Journal for ImmunoTherapy of Cancer
Background Limited data exist for management strategies targeting immunotherapy-related enteritis (irEnteritis). Systemic corticosteroids are commonly used but often are limited by adverse events. Enteric corticosteroids such as budesonide offer an attractive alternative; however, the ileocolonic release of enteric-coated budesonide has limited utility for diffuse enteritis. Open-capsule budesonide (OCB) is a novel therapeutic approach that offers drug delivery throughout the small bowel. We report outcomes in patients treated with OCB for confirmed or suspected irEnteritis. Methods This retrospective cohort included all individuals treated with OCB for irEnteritis at Memorial Sloan Kettering from July 2018 to August 2023. Primary outcomes included clinical response, clinical remission, and corticosteroid-free remission following OCB. Secondary outcomes were OCB-related adverse events and efficacy by gastrointestinal toxicity location. Results 19 patients (53% female) with irEnteritis were treated with OCB. All patients presented with diarrhea; 15 (79%) reported anorexia with median 6 kg weight loss. 17 patients (89%) underwent esophagogastroduodenoscopy with biopsies revealing enteritis in all; 8 (42%) had concomitant colitis. 15 (79%) patients were treated previously with systemic corticosteroids: 8 (53%) were corticosteroid-dependent while 7 (47%) demonstrated non-response. 18 patients (95%) achieved clinical response, 15 (79%) attained clinical remission, and 11 (58%) had corticosteroid-free remission. Response to OCB was rapid with improvement noted after a median 4 days. 14 (74%) patients restored their pre-irEnteritis weight by OCB cessation. One mild, self-resolving adverse event was reported. Conclusions OCB is a safe and effective therapy for irEnteritis. OCB avoids systemic immunosuppression and successfully achieves clinical response and remission even in patients previously nonresponsive to systemic corticosteroids. Future studies are needed to optimize indications and duration.
5 July 2024 in American Journal of Gastroenterology
INTRODUCTION: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is frequently used to risk-stratify pancreatic cystic lesions (PCLs). Rising PCL incidence and developments in tissue acquisition and specimen analysis necessitate updated appraisal of EUS-FNA safety, particularly the risk of postprocedure pancreatitis, the most common EUS-FNA-related adverse event. Our systematic review aims to accurately quantify the risk of EUS-FNA-related pancreatitis to best inform decisions regarding EUS-FNA's optimal role in PCL workup. METHODS: We performed systematic searches in 4 databases from inception to April 2024 for original English-language studies investigating EUS-FNA-related pancreatitis. We extracted data on demographics and EUS-FNA-related pancreatitis risk, severity, and risk factors. These were meta-analyzed through the DerSimonian Laird Method using a random-effects model. Meta-regression of pancreatitis risk was performed to delineate associations with clinical and procedural characteristics. RESULTS: Sixty-four studies comprised 8,086 patients and reported 110 EUS-FNA-related pancreatitis events. Pooled risk of EUS-FNA-related pancreatitis was 1.4% (95% confidence intervals, −0.8% to 3.5%; I 2 = 0.00), which was predominantly of mild severity (67%) and uniformly nonfatal. Pancreatitis risk lacked significant association with sample size, age, sex, cyst size, needle caliber, or passes, although we noted trends toward higher risk in studies published after 2015, those using higher gauge needles (19 G vs 22 G/25 G), and those performing EUS-guided through-the-needle biopsy. DISCUSSION: We note with high certainty that pancreatitis after EUS-FNA of PCLs is infrequent and mild in severity with no mortality in the included cohort. EUS-guided through-the-needle biopsy may serve as a significant risk factor for EUS-FNA-related pancreatitis risk; however, further studies are needed to delineate other predisposing characteristics.
9 May 2025 in Gastrointestinal Endoscopy
30 May 2025 in Clinical Endoscopy
Background/Aims: The real-world efficacy of computer-aided detection (CADe) systems, such as GI Genius (Medtronic), is unclear. We examined the colonoscopy metrics using CADe alone and with a mucosal exposure device (EndoCuff; Olympus) in a real-world setting.Methods: We retrospectively reviewed screening and surveillance colonoscopies before, during, and after CADe use in a large tertiary care center. Outcomes included the adenomas per colonoscopy (APC), sessile serrated lesions per colonoscopy, adenoma detection rate (ADR), sessile serrated lesion detection rate (SSLDR), advanced ADR, total polyp detection rate, and true histology rate. The ADR and SSLDR were further examined according to size, colon location, and EndoCuff use.Results: A total of 798 colonoscopies were performed, including 386 pre-CADe, 178 CADe, and 234 post-CADe. In cases where CADe was used with the EndoCuff, the 1 to 5 mm ADR increased from 36.3% (pre-CADe) to 52.1% (CADe) (p=0.01). The 1 to 5 mm SSLDR increased from 9.6% (pre-CADe) to 17.1% (CADe) (p=0.02). The right-sided ADR increased from 30.8% (pre-CADe) to 42.7% (CADe) (p=0.03). The right-sided SSLDR increased from 12.3% (pre-CADe) to 24.8% (CADe) (p<0.001). No significant changes were observed when only CADe was used. No differences were found in other outcome measures. Post-CADe metrics returned to pre-CADe levels.Conclusions: GI Genius is useful for identifying small and right-sided polyps only when used with the EndoCuff.
4 October 2023 in Endoscopy International Open
Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is an emerging procedure that lacks technical standardization with limited adoption beyond expert centers. We surveyed high-volume endosonographers about the technical aspects of EUS-GE to describe how the procedure is currently performed at expert centers and identify targets for standardization. Methods Invitations to complete an electronic survey were distributed to 21 expert EUS practitioners at 19 U.S. centers. Respondents were surveyed about technical aspects of EUS-GE, indications, efficacy, safety, and attitudes toward the procedure. Results All 21 (100%) invited expert endoscopists completed the survey. Nine (42.9%) reported performing >10 EUS-GEs in the last 12 months. About half (47.6%, 10/21) puncture the target loop prior to lumen-apposing metal stent (LAMS) introduction, most often to confirm the loop is jejunum. No respondents reported guidewire placement prior to LAMS introduction. Most (71.4%, 15/21) do not use a guidewire at any time, while 28.6% (6/21) reported wire placement after distal flange deployment to secure the tract during apposition. Eight (38.1%, 8/21) reported at least one major adverse event, most commonly intraperitoneal LAMS deployment (87.5%, 7/8). Factors most often reported as advantageous for EUS-GE over enteral stenting included lack of papilla interference (33.3%, 7/21) and decreased occlusion risk (23.8%, 5/21). Conclusions Significant variation in performance technique for EUS-GE exists among expert US endoscopists, which may hinder widespread adoption and contribute to inconsistencies in reported patient outcomes. The granularity provided by these survey results may identify areas to focus standardization efforts and guide future studies on developing an ideal EUS-GE protocol.