Krzysztof Siwiec

Krzysztof Siwiec

Auto-generated profile, based on publicly available information

Krzysztof Siwiec

Institute of Microelectronics & Optoelectronics, Warsaw University of Technology, ul. Koszykowa 75, 00-662, POLAND

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016
Verified
Conference Paper
Closed access
PNPawel Narczyk
Pawel Narczyk
KSKrzysztof Siwiec
Krzysztof Siwiec
WPWitold A. Pleskacz
Witold A. Pleskacz
An analog front-end, with a new temperature calibration method, for an accurate temperature measurement of a human body has been presented. The discussed AFE consists of a current reference, a precision current source, a programmable gain amplifier, a voltage source proportional to absolute temperature and on-chip temperature calibration resistor. Human body temperature can be measured in the range from +25 °C to +45 °C at the operating temperature of an IC in the range from -40 °C to +125 °C with 0.1 °C precision. The presented analog front-end consumes no more than 180 uW and was designed in UMC CMOS 130 nm technology.

1 April 2012
Verified
Conference Paper
Closed access
KSKrzysztof Siwiec
Krzysztof Siwiec
TBTomasz Borejko
Tomasz Borejko
WPWitold A. Pleskacz
Witold A. Pleskacz
In this paper a low-voltage LC voltage-controlled oscillator (VCO) design automation tool has been presented. The tool is based on design methodology, which takes under consideration trade-offs between power consumption, phase noise and tuning range. NMOS only architecture is considered because of its capability to work with low supply voltages. One of the goals, while creating the tool, was to make it technology independent. This was achieved by creating SKILL scripts that allows fast configuration of design library for specified technology. Trade-offs between power consumption, phase noise and tuning range are analyzed and based on them design flow has been proposed. Finally two design examples in 90 and 130 nm CMOS technology have been presented.

1 June 2015
Verified
Conference Paper
Closed access
KSKrzysztof Siwiec
Krzysztof Siwiec
KMKrzysztof Marcinek
Krzysztof Marcinek
TBTomasz Borejko
Tomasz Borejko
AJAdam Jarosz
Adam Jarosz
JKJakub Kopanski
Jakub Kopanski
WPWitold A. Pleskacz
Witold A. Pleskacz
A system-on-chip allowing dynamic measurement and processing of the most important human physiological parameters has been presented. The BioChip consists of analog front-ends, analog to digital converters and a two core 32-bit microcontroller Azurite. The two core architecture allows to control the signals' acquisition, data processing and communication with the peripherals simultaneously. The microcontroller was equipped with many interfaces: 8×UART, 2×SPI, I2C and 24 GPIOs. The clock frequency of the microprocessor is configurable from 32 kHz up to 120 MHz. The BioChip comes in front of the growing demand for portable health monitoring. It will allow for easy integration with a new generation of devices, such as smartphones, and also it will allow adding new functionalities in the area of telemedicine. The BioChip was designed in UMC CMOS 130 nm technology and the chip area is 25 mm 2 .

1 April 2011
Verified
Conference Paper
Closed access
KSKrzysztof Siwiec
Krzysztof Siwiec
TBTomasz Borejko
Tomasz Borejko
WPWitold A. Pleskacz
Witold A. Pleskacz
In this paper PLL Design tool, created in Matlab from MathWorks, has been presented. The tool allows to analyze loop stability and phase noise of PLL, based on phase-locked loop linear model. Fast evaluation of loop filter components values for popular passive and active filters is possible. The created tool allows to analyze PLL parameters, like loop filter components values, VCO gain and charge pump current variations impact on loop stability and phase-noise. Algorithm for phase-noise calculation, based on transient PLL simulation, has also been implemented. Thanks to these features the created tool is a valuable aid for PLL designer on all design steps.

1 April 2016
Verified
Conference Paper
Closed access
KSKrzysztof Siwiec
Krzysztof Siwiec
KMKrzysztof Marcinek
Krzysztof Marcinek
PBPiotr Boguszewicz
Piotr Boguszewicz
TBTomasz Borejko
Tomasz Borejko
AHAleh Halauko
Aleh Halauko
WPWitold A. Pleskacz
Witold A. Pleskacz
The BioSoC is a highly integrated SoC that consists of analog front-ends, analog to digital converters and a 32-bit microcontroller - Adelite. The designed IC allows for dynamic acquisition and processing of the most important human physiological parameters. The provided analog interfaces to external electrodes and sensors allow measurement of electrocardiograms (ECG), electromyograms (EMG), skin temperature and resistance, and respiration rate (RR). After analog processing signals are sampled and digitized in analog-to-digital converters they can be further processed in a 32-bit microcontroller Adelite. The clock frequency of the microprocessor core is configurable from 32 kHz up to 16 MHz. The microcontroller is equipped with many digital interfaces and peripherals, such as 2×UART and 2×SPI with DMA channels, 16 GPIOs and 5 timers along with RTC. The BioSoC makes it possible to build highly integrated devices with rich functionalities in the area of telemedicine that respond to the growing demand for portable health monitoring. The BioSoC was designed and fabricated in UMC CMOS 130 nm technology process and occupies the area of 25mm 2 .

1 June 2014
Verified
Conference Paper
Closed access
DPDaniel Pietron
Daniel Pietron
KSKrzysztof Siwiec
Krzysztof Siwiec
JKJakub Kopanski
Jakub Kopanski
WPWitold A. Pleskacz
Witold A. Pleskacz
In this paper, the RF chain for the Bluetooth receiver, implemented in the UMC CMOS 130 nm process, is presented. Project was carried out at the electrical schematic level. Due to the most beneficial parameters, the low-IF architecture was selected. The circuit is formed by a single-end low noise amplifier (LNA), an active balun and a quadrature double-balanced passive mixer. The Bluetooth receiver operates in 2.4 GHz ISM band and complies with Bluetooth's specification (version 4.0 EDR) [1]. Design goals, such as noise figure (NF) and third order intermodulation point (IIP3), were calculated on the basis of the Bluetooth's specification. The circuit exhibits a low noise figure of 2.32 dB and dissipates only 3.34 mW, what makes it suitable for low-power applications.