1 March 2009 in Clinical Biomechanics
1 April 2000 in American Journal of Roentgenology
OBJECTIVE. Our objective was to evaluate a combined method of contrast material bolus followed by saline solution flush for thoracic helical CT and statistical comparison with a uniphasic injection protocol.MATERIALS AND METHODS. Fifty patients underwent helical CT of the thorax using 60 ml of contrast material (370 mg I/ml) followed by flushing with 30 ml of physiologic saline solution. These 50 patients had been examined before using our previous protocol, 75 ml of the same contrast material without a subsequent saline solution. Mean attenuation values for both protocols were measured in the superior vena cava, the pulmonary trunk, and the ascending aorta. Image artifacts and mediastinal and hilar depiction were graded and compared.RESULTS. Mean attenuation values in the superior vena cava were considerably higher in the regimen without saline solution flush (459 H versus 352 H) and in the pulmonary trunk and the ascending aorta were almost identical for both protocols. Injection of saline solution dimi...
1 June 2002 in American Journal of Roentgenology
OBJECTIVE. The purpose of this study was to compare multidetector CT (MDCT) of the thoracic and lumbar segments of the spine with MR imaging and conventional radiography for bone lesion detection and for evaluating the risk of vertebral fracture in multiple myeloma.SUBJECTS AND METHODS. Eighteen patients with multiple myeloma stage III (according to the criteria of Durie and Salmon) underwent MDCT, conventional radiography, and MR imaging of the lumbar and thoracic spine. MDCT was performed using a standard protocol with no contrast material. Source images were reconstructed using an effective slice thickness of 3 mm with an overlapping reconstruction increment (0.8 mm). Secondary coronal and sagittal multiplanar reformations were exclusively used for establishing the diagnosis. Findings were compared with those of MR imaging and conventional radiography.RESULTS. In all patients, coronal and sagittal multiplanar reformations depicted the extent of osseous destruction and provided detailed information abou...
5 May 2009 in Tissue Engineering Part A
Autologous fibrin-based tissue-engineered heart valves have demonstrated excellent potential as patient-derived valve replacements. The present pilot study aims to evaluate the structure and mechanical durability of fibrin-based heart valves after implantation in a large-animal model (sheep). Tissue-engineered heart valves were molded using a fibrin scaffold and autologous arterial-derived cells before 28 days of mechanical conditioning. Conditioned valves were subsequently implanted in the pulmonary trunk of the same animals from which the cells were harvested. After 3 months in vivo , explanted valve conduits (n = 4) had remained intact and exhibited native tissue consistency, although leaflets demonstrated insufficiency because of tissue contraction. Routine histology showed remarkable tissue development and cell distribution, along with functional blood vessel ingrowth. A confluent monolayer of endothelial cells was present on the valve surface, as evidenced by scanning electron microscopy and positive von Willebrand factor staining. Immunohistochemistry and extracellular matrix (ECM) assay demonstrated complete resorption of the fibrin scaffold and replacement with ECM proteins. Transmission electron microscopy revealed mature collagen formation and viable, active resident tissue cells. The preliminary findings of implanted fibrin-based tissue-engineered heart valves are encouraging, with excellent tissue remodeling and structural durability after 3 months in vivo . The results from this pilot study highlight the potential for construction of completely “autologous” customized tissue-engineered heart valves based on a patient-derived fibrin scaffold.
1 June 2010 in Biomaterials