Helder Rocha da Silva Araújo

Helder Rocha da Silva Araújo

Auto-generated profile, based on publicly available information

Helder Rocha da Silva Araújo

Department of Orthopaedics and Traumatology, Federal University of Goiás (UFG), Goiânia 74605-050, Brazil

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2025 in Life
Verified
Journal Article
Open access
PDF file
ATAndrei MACHADO VIEGAS Trindade
Andrei MACHADO VIEGAS Trindade
Leonardo Pinheiro RezendeLeonardo Pinheiro Rezende
Leonardo Pinheiro Rezende
HAHelder Rocha da Silva Araújo
Helder Rocha da Silva Araújo
RPRodolfo Parreira
Rodolfo Parreira
COClaudia Santos Oliveira
Claudia Santos Oliveira
In the context of the rising demand for total knee arthroplasty (TKA) in older adults and persistent uncertainty about the quality of long-term functional recovery, this study evaluated elderly patients’ mobility after unilateral TKA via a transquadriceps approach using instrumented Timed Up and Go (TUG) tests. A total of 20 patients treated between 2022 and 2024 at a tertiary hospital were invited to participate in this observational, retrospective, descriptive study, and 19 met the inclusion criteria (age 50–80 and Kellgren–Lawrence ≥ 4). The participants performed two TUG trials at two postoperative time points (18 and 53 months), with an inertial measurement unit (G-sensor) capturing 15 kinematic variables. When comparing the postoperative time points, it was found that the total TUG duration remained stable (14.97 ± 3.48 vs. 15.47 ± 2.93 s; p = 0.58), while the mid-turning peak velocity increased significantly (106.44 ± 30.96 vs. 132.77 ± 30.82°/s; p = 0.0039; r = 0.88). The end-turning velocity and sit-to-stand parameters showed small-to-moderate effect size gains without statistical significance. These findings suggest that, in the first year following surgery, patients continue to experience difficulties with movement fluidity and motor control—especially during turning—underscoring the value of segmented, sensor-based assessments and the need for extended rehabilitation protocols that emphasize rotational control and balance. These findings provide clinically relevant parameters that can support future interventional studies and help guide rehabilitation planning after TKA.

21 February 2026 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
ATAndrei MACHADO VIEGAS Trindade
Andrei MACHADO VIEGAS Trindade
Leonardo Pinheiro RezendeLeonardo Pinheiro Rezende
Leonardo Pinheiro Rezende
HAHelder Rocha da Silva Araújo
Helder Rocha da Silva Araújo
RPRodolfo Parreira
Rodolfo Parreira
CSClaudio Santili
Claudio Santili
COClaudia Santos Oliveira
Claudia Santos Oliveira
Background/Objectives: The clinical superiority of rotating-bearing (RB) versus fixed-bearing (FB) total knee arthroplasty (TKA) remains controversial despite the proposed biomechanical advantages of mobile-bearing designs. Objective gait assessment with inertial measurement units (IMUs) provides a measurable view of functional recovery that may complement patient-reported outcome measures (PROMs). This study compared spatiotemporal gait parameters between FB and RB TKA over 24 months. Methods: This prospective longitudinal comparative study enrolled 57 patients undergoing primary unilateral TKA for end-stage knee osteoarthritis. Spatiotemporal gait parameters (gait velocity, cadence, and stance-phase duration) were measured using wireless IMUs (G-WALK system) at 6, 12, and 24 months post-surgery. WOMAC and the 10-point Geriatric Locomotive Function Scale (GLFS-10P) were assessed at 12 and 24 months. Group, time, and Group × Time effects were analyzed using linear mixed-effects models. Results: Both groups improved during follow-up, with performance largely plateauing between 12 and 24 months. At 24 months, there were no significant differences between groups in gait velocity (FB 1.17 vs. RB 1.16 m/s; p = 0.65), cadence (99.8 vs. 97.4 steps/min; p = 0.72), or stance-phase duration (59.3% vs. 59.0%; p = 0.82). Group × Time interactions were not significant across gait outcomes. WOMAC and GLFS-10P improved similarly in both groups (p > 0.05). Cadence was inversely correlated with the WOMAC function subscale at 24 months (rho = −0.563; p = 0.036). Conclusions: FB and RB bearing designs showed similar objective gait recovery trajectories and PROM improvements through 24 months after primary TKA, suggesting no intermediate-term functional advantage from bearing design.

5 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ATAndrei MACHADO VIEGAS Trindade
Andrei MACHADO VIEGAS Trindade
Leonardo Pinheiro RezendeLeonardo Pinheiro Rezende
Leonardo Pinheiro Rezende
HAHelder Rocha da Silva Araújo
Helder Rocha da Silva Araújo
RPRodolfo Parreira
Rodolfo Parreira
CSClaudio Santili
Claudio Santili
COClaudia Santos Oliveira
Claudia Santos Oliveira
Background/Objectives: The clinical superiority of rotating-bearing (RB) versus fixed-bearing (FB) total knee arthroplasty (TKA) remains controversial despite the proposed biomechanical advantages of mobile-bearing designs. Objective gait assessment with inertial measurement units (IMUs) provides a measurable view of functional recovery that may complement patient-reported outcome measures (PROMs). This study compared spatiotemporal gait parameters between FB and RB TKA over 24 months. Methods: This prospective longitudinal comparative study enrolled 47 patients undergoing primary unilateral TKA for end-stage knee osteoarthritis. Spatiotemporal gait parameters (gait velocity, cadence, and stance-phase duration) were measured using wireless IMUs (G-WALK system) at 6, 12, and 24 months post-surgery. WOMAC and the 10-point Geriatric Locomotive Function Scale (GLFS-1) were assessed at 12 and 24 months. Group, time, and Group × Time effects were analyzed using linear mixed-effects models. Results: Both groups improved during follow-up, with performance largely plateauing between 12 and 24 months. At 24 months, there were no significant differences between groups in gait velocity (FB 1.17 vs. RB 1.16 m/s; p = 0.65), cadence (99.8 vs. 97.4 steps/min; p = 0.72), or stance-phase duration (59.3% vs. 59.0%; p = 0.82). Group × Time interactions were not significant across gait outcomes. WOMAC and GLFS-1 improved similarly in both groups (p > 0.05). Cadence was inversely correlated with the WOMAC function subscale at 24 months (rho = −0.563; p = 0.036). Conclusions: FB and RB bearing designs showed similar objective gait recovery trajectories and PROM improvements through 24 months after primary TKA, suggesting no intermediate-term functional advantage from bearing design.

1 January 2022 in Acta Ortopedica Brasileira
Verified
Journal Article
Open access
HAHelder Rocha da Silva Araujo
Helder Rocha da Silva Araujo
RHRenan Simoes Heyn
Renan Simoes Heyn
MTMarcelo Rodrigues Torres
Marcelo Rodrigues Torres
HJHalley Paranhos Junior
Halley Paranhos Junior
UJUlbiramar Correa da Silva Junior
Ulbiramar Correa da Silva Junior
ÊOÊNIO OLIVEIRA
ÊNIO OLIVEIRA
Osteoarthritis is a major cause of disability worldwide. Objective: To evaluate the effects of Total Knee Arthroplasty of subjects with knee osteoarthritis by the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC ). Methods: Prospective, non-randomized study with convenience sampling. We included subjects with knee osteoarthritis with indication for surgical treatment. We used WOMAC to evaluate the level of pain, joint stiffness, physical activity, and quality of life in the preoperative and postoperative phase six months after unilateral surgery. We compared WOMAC to the factors age, gender, Body Mass Index and the type of angular deformity of the knee. Results: In total, we analyzed 58 patients with significant improvements in pain relief, joint stiffness, level of physical activity, and quality of life six months after total knee arthroplasty according to WOMAC. Conclusion: Total knee arthroplasty showed positive effects on the quality of life of patients with knee osteoarthritis. Level of Evidence II, Cohort Study.

5 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ATAndrei MACHADO VIEGAS Trindade
Andrei MACHADO VIEGAS Trindade
Leonardo Pinheiro RezendeLeonardo Pinheiro Rezende
Leonardo Pinheiro Rezende
RPRodolfo Parreira
Rodolfo Parreira
CSCláudio Santili
Cláudio Santili
HAHelder Rocha da Silva Araújo
Helder Rocha da Silva Araújo
COClaudia Santos Oliveira
Claudia Santos Oliveira
This case report describes longitudinal gait mechanics in a 62-year-old man who underwent left total knee arthroplasty (TKA) and subsequently laparoscopic sleeve gastrectomy with massive weight loss. Gait was evaluated using a wearable inertial sensor system at 6 months (T1) and 12 months (T2) after arthroplasty, alongside functional mobility and endurance tests (Timed Up and Go and 2-minute walk). Body mass decreased from 120 kg (BMI approximately 43 kg/m2) to 69 kg (BMI approximately 25 kg/m2) between T1 and T2. Despite the substantial reduction in mechanical loading, spatiotemporal gait parameters and pelvic kinematics remained largely stable, with persistent asymmetry and a compensatory gait strategy. Acceleration-derived estimates suggested approximately 42.5% mechanical offloading after weight loss. These findings indicate that, in this patient, massive postoperative weight loss did not translate into marked improvements in gait mechanics within the first year after TKA, underscoring the need for targeted rehabilitation even after successful weight reduction.

Verified
Journal Article
Open access
PDF file
ATAndrei MACHADO VIEGAS Trindade
Andrei MACHADO VIEGAS Trindade
Leonardo Pinheiro RezendeLeonardo Pinheiro Rezende
Leonardo Pinheiro Rezende
HAHelder Rocha da Silva Araújo
Helder Rocha da Silva Araújo
JJJunichiro Sado Junior
Junichiro Sado Junior
HJHalley Paranhos Júnior
Halley Paranhos Júnior
COClaudia Santos Oliveira
Claudia Santos Oliveira
Background: The choice between fixed-bearing (FB) and mobile-bearing (MB) prostheses in total knee arthroplasty (TKA) remains controversial, and longitudinal evidence based on objective instrumented assessment is limited. Objectives: To compare global spatiotemporal gait performance and ambulation capacity across three postoperative assessments in patients receiving FB versus MB/rotating-platform implants. Methods: In this retrospective, longitudinal, observational cohort study, patients who had undergone primary unilateral TKA were assessed at up to three postoperative visits approximately 12 months apart, the first at a median of 12 months after surgery. Gait speed, cadence, stride length, a step-time symmetry index and a gait quality index were obtained from a single lumbar-mounted inertial measurement unit during steady-state level walking, and ambulation capacity was measured with the 2-Minute Walk Test (2MWT). Linear mixed-effects models with a random intercept per patient, adjusted for age and sex, were fitted for all six outcomes, with time specified both as a linear term and, in a sensitivity analysis, as a categorical factor yielding estimated marginal means and between-group contrasts at each visit. Results: A total of 105 observations from 54 patients were analysed (29 FB, 25 MB/PS-RP). Groups were comparable at the first assessment on age, sex, body mass index, WOMAC score and all gait outcomes. No between-group difference reached statistical significance for any outcome, in either the linear or the categorical specification; all 18 visit-specific contrasts included the null value. Within the FB group, gait speed, stride length, the symmetry index, the gait quality index and 2MWT distance decreased significantly between the second and third assessments, a change based on six patients. Conclusions: Under the conditions of this study, no significant differences in global spatiotemporal gait performance or ambulation capacity were detected between FB and MB/rotating-platform prostheses. Because the study was not designed or powered as an equivalence trial, lacks preoperative and joint-level kinematic data, and cannot separate bearing design from the surgical approach with which it was collinear, these findings do not establish that the two designs perform equivalently.