17 May 2015 in Journal of NeuroEngineering and Rehabilitation
The effectiveness of transcranial magnetic stimulation (TMS) depends highly on the coil orientation relative to the subject’s head. This implies that the direction of the induced electric field has a large effect on the efficiency of TMS. To improve future protocols, knowledge about the relationship between the coil orientation and the direction of the induced electric field on the one hand, and the head and brain anatomy on the other hand, seems crucial. Therefore, the induced electric field in the cortex as a function of the coil orientation has been examined in this study. The effect of changing the coil orientation on the induced electric field was evaluated for fourteen cortical targets. We used a finite element model to calculate the induced electric fields for thirty-six coil orientations (10 degrees resolution) per target location. The effects on the electric field due to coil rotation, in combination with target site anatomy, have been quantified. The results confirm that the electric field perpendicular to the anterior sulcal wall of the central sulcus is highly susceptible to coil orientation changes and has to be maximized for an optimal stimulation effect of the motor cortex. In order to obtain maximum stimulation effect in areas other than the motor cortex, the electric field perpendicular to the cortical surface in those areas has to be maximized as well. Small orientation changes (10 degrees) do not alter the induced electric field drastically. The results suggest that for all cortical targets, maximizing the strength of the electric field perpendicular to the targeted cortical surface area (and inward directed) optimizes the effect of TMS. Orienting the TMS coil based on anatomical information (anatomical magnetic resonance imaging data) about the targeted brain area can improve future results. The standard coil orientations, used in cognitive and clinical neuroscience, induce (near) optimal electric fields in the subject-specific head model in most cases.
1 November 2015 in Parkinsonism & Related Disorders
9 January 2018 in Neurology
Objective To assess, in a cross-sectional study, the feasibility and immediate efficacy of laser shoes, a new ambulatory visual cueing device with practical applicability for use in daily life, on freezing of gait (FOG) and gait measures in Parkinson disease (PD). Methods We tested 21 patients with PD and FOG, both “off” and “on” medication. In a controlled gait laboratory, we measured the number of FOG episodes and the percent time frozen occurring during a standardized walking protocol that included FOG provoking circumstances. Participants performed 10 trials with and 10 trials without cueing. FOG was assessed using offline video analysis by an independent rater. Gait measures were recorded in between FOG episodes with the use of accelerometry. Results Cueing using laser shoes was associated with a significant reduction in the number of FOG episodes, both “off” (45.9%) and “on” (37.7%) medication. Moreover, laser shoes significantly reduced the percent time frozen by 56.5% (95% confidence interval [CI] 32.5–85.8; p = 0.004) when “off” medication. The reduction while “on” medication was slightly smaller (51.4%, 95% CI −41.8 to 91.5; p = 0.075). These effects were paralleled by patients9 positive subjective experience on laser shoes9 efficacy. There were no clinically meaningful changes in the gait measures. Conclusions These findings demonstrate the immediate efficacy of laser shoes in a controlled gait laboratory, and offer a promising intervention with potential to deliver in-home cueing for patients with FOG. Classification of evidence This study provides Class III evidence that for patients with PD, laser shoes significantly reduce FOG severity (both number and duration of FOG episodes).
21 June 2013 in Physics in Medicine & Biology
Volume conduction models can help in acquiring knowledge about the distribution of the electric field induced by transcranial magnetic stimulation. One aspect of a detailed model is an accurate description of the cortical surface geometry. Since its estimation is difficult, it is important to know how accurate the geometry has to be represented. Previous studies only looked at the differences caused by neglecting the complete boundary between cerebrospinal fluid (CSF) and grey matter (Thielscher et al 2011 NeuroImage 54 234-43, Bijsterbosch et al 2012 Med. Biol. Eng. Comput. 50 671-81), or by resizing the whole brain (Wagner et al 2008 Exp. Brain Res. 186 539-50). However, due to the high conductive properties of the CSF, it can be expected that alterations in sulcus width can already have a significant effect on the distribution of the electric field. To answer this question, the sulcus width of a highly realistic head model, based on T1-, T2- and diffusion-weighted magnetic resonance images, was altered systematically. This study shows that alterations in the sulcus width do not cause large differences in the majority of the electric field values. However, considerable overestimation of sulcus width produces an overestimation of the calculated field strength, also at locations distant from the target location.
28 August 2014 in Medical & Biological Engineering & Computing
24 June 2014 in Journal of Neurology