Hartmut Gemmeke

Hartmut Gemmeke

Auto-generated profile, based on publicly available information

Hartmut Gemmeke

Karlsruher Institut für Technologie (Germany)

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2007 in IEEE International Ultrasonics Symposium
Verified
Conference Paper
Closed access
NRN. V. Ruiter
N. V. Ruiter
RSRuss Schnell
Russ Schnell
MZM. Zapf
M. Zapf
HGH. Gemmeke
H. Gemmeke
Our experimental setup for ultrasound computer tomography (USCT) has a cylindrical aperture with a diameter of 18 cm and height of 15 cm. In this setup ultrasound can travel over long distances up to 50 cm. Phase aberration due to speed of sound variations cause many pulses not to overlap in the reflectivity reconstruction. 3D speed of sound (SOS) maps were calculated using the recorded data and applied for correction. Due to a sparse sampling of the received transmission signals, the resulting speed of sound maps are noisy and of low detail. But the accuracy of the average speed of sound is sufficient for phase aberration correction of the reflection images down to object size of approx. 1 mm and increases the image quality significantly. Our work shows that high resolution USCT is not possible without phase aberration correction using SOS information.

1 April 2016
Verified
Conference Paper
Closed access
PDF file
NRN. V. Ruiter
N. V. Ruiter
THT. Hopp
T. Hopp
MZM. Zapf
M. Zapf
EKE. Kretzek
E. Kretzek
HGH. Gemmeke
H. Gemmeke

19 September 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
UTUlas Taskin
Ulas Taskin
JNJoost Van Der Neut
Joost Van Der Neut
HGHartmut Gemmeke
Hartmut Gemmeke
KDKoen W. A. van Dongen
Koen W. A. van Dongen
Whole breast ultrasound scanning systems are used to screen a women’s breast for suspicious lesions. Typically, the transducers are located at fixed positions at relatively large distances from the breast to avoid any contact with the breast. Unfortunately, these large distances give rise to large spatial domains to be imaged. These large domains hamper the applicability of imaging by inversion. To reduce the size of the spatial computational domain, we present a two-dimensional redatuming method based on Hankel decomposition of the measured field. With this method, the field measured over an arbitrary-shaped closed curve can be redatumed to a new curve enclosing a smaller spatial domain. Additional advantages of the proposed method are that it allows to account for the finite size and orientation of a transducer and that it is robust to noise. The proposed method is successfully validated using synthetic and measured data and the results show that the recorded field can be redatumed to any position in the embedding.

10 April 2023
Verified
Conference Paper
Closed access
PDF file
THTorsten Hopp
Torsten Hopp
MZMichael Zapf
Michael Zapf
LFLaura Fernandez-Lago
Laura Fernandez-Lago
FFFridtjof Feldbusch
Fridtjof Feldbusch
HGHartmut E. Gemmeke
Hartmut E. Gemmeke
NRNicole V. Ruiter
Nicole V. Ruiter
Ultrasound Tomography (USCT) is an emerging technology for early breast cancer detection. At Karlsruhe Institute of Technology we recently realized a new generation of full 3D USCT device with a pseudo-randomly sampled hemispherical aperture. In this paper we summarize first imaging results with phantoms and first volunteer images. Using a gelatin phantom with PVC inclusions we evaluated transmission imaging, which showed a deviation from the ground truth of less than 5 m/s in the sound speed and 0:2 dB/cm in the attenuation for the phantom body and less than 15 m/s and 0:2 dB/cm for an inclusion with a diameter of 2:2 cm. Geometric errors are in average in the range of 0:2 cm. For reflectivity imaging we showed that the point spread function is nearly isotropic and with an average of 0:26 mm close to the theoretical predictions for the current system. While the system is still in final commissioning, the results of the phantom and volunteer imaging are very promising: after further calibration and deeper analysis with phantoms we aim at starting a clinical study.