Lin-Wen Hu

Lin-Wen Hu

Auto-generated profile, based on publicly available information

Lin-Wen Hu

Mem. ASME Nuclear Reactor Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2011 in Discover Nano
Verified
Journal Article
Open access
PDF file
CGCraig Gerardi
Craig Gerardi
JBJacopo Buongiorno
Jacopo Buongiorno
LHLin-Wen Hu
Lin-Wen Hu
TMThomas McKrell
Thomas McKrell
Infrared thermometry was used to obtain first-of-a-kind, time- and space-resolved data for pool boiling phenomena in water-based nanofluids with diamond and silica nanoparticles at low concentration (<0.1 vol.%). In addition to macroscopic parameters like the average heat transfer coefficient and critical heat flux [CHF] value, more fundamental parameters such as the bubble departure diameter and frequency, growth and wait times, and nucleation site density [NSD] were directly measured for a thin, resistively heated, indium-tin-oxide surface deposited onto a sapphire substrate. Consistent with other nanofluid studies, the nanoparticles caused deterioration in the nucleate boiling heat transfer (by as much as 50%) and an increase in the CHF (by as much as 100%). The bubble departure frequency and NSD were found to be lower in nanofluids compared with water for the same wall superheat. Furthermore, it was found that a porous layer of nanoparticles built up on the heater surface during nucleate boiling, which improved surface wettability compared with the water-boiled surfaces. Using the prevalent nucleate boiling models, it was possible to correlate this improved surface wettability to the experimentally observed reductions in the bubble departure frequency, NSD, and ultimately to the deterioration in the nucleate boiling heat transfer and the CHF enhancement.

13 June 2007 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
Roberto RusconiRoberto Rusconi
Roberto Rusconi
WWWesley C. Williams
Wesley C. Williams
JBJacopo Buongiorno
Jacopo Buongiorno
RPRoberto Piazza
Roberto Piazza
LHLin-Wen Hu
Lin-Wen Hu

21 October 2015 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
EFEric C. Forrest
Eric C. Forrest
LHLin-Wen Hu
Lin-Wen Hu
JBJacopo Buongiorno
Jacopo Buongiorno
TMThomas J. McKrell
Thomas J. McKrell

5 June 2019 in Nuclear Technology
Verified
Journal Article
Closed access
RRR. R. Romatoski
R. R. Romatoski
LHL. W. Hu
L. W. Hu
An important fluoride-salt-cooled high-temperature reactor (FHR) development step is to design, build, and operate a test reactor. The uncertainties of the coolant thermophysical properties range between 2% and 20%. This study determines the effects of these high uncertainties by incorporating uncertainty propagation in a thermal-hydraulic safety analysis for test reactor licensing. A hot channel thermal-hydraulic model, Monte Carlo statistical sampling uncertainty propagation, and a limiting safety systems settings (LSSS) approach are combined to ensure sufficient margin to fuel and material thermal limits during steady-state operation while incorporating margin for high-uncertainty inputs. The method calculates LSSS parameters to define safe operation. The methodology is applied to two test reactors currently considered, i.e., China’s first Solid Fueled Thorium Molten Salt Reactor (TMSR-SF1) pebble bed design and Massachusetts Institute of Technology’s Transportable FHR prismatic core design; two candidate coolants, i.e., flibe (LiF-BeF2) and nafzirf (NaF-ZrF4); and forced flow and natural circulation conditions to compare operating regions and LSSS power (maximum power not exceeding any thermal limits). The calculated operating region accounts for uncertainty (2σ) with an LSSS power for forced flows of 25.37 ± 0.72, 22.56 ± 1.15, 21.28 ± 1.48, and 11.32 ± 1.35 MW for pebble flibe, pebble nafzirf, prismatic flibe, and prismatic nafzirf, respectively. The pebble bed has superior heat transfer with an operating region reduced ∼10% less when switching coolants and ∼50% smaller uncertainty than the prismatic. The maximum fuel temperature constrains the pebble bed while the maximum coolant temperature constrains the prismatic due to different dominant heat transfer modes. Sensitivity analysis revealed that (1) thermal conductivity and thus conductive heat transfer dominate in the prismatic design while convection is superior in the pebble bed and (2) the impact of thermophysical property uncertainties is ranked and should be considered for experimental measurements in the following order: thermal conductivity, heat capacity, density, and last, viscosity. Broadly, the methodology incorporates uncertainty propagation that can be used to evaluate parametric uncertainties to satisfy guidelines for nonpower reactor licensing applications, and its application shows that the pebble bed is more attractive for thermal-hydraulic safety. Although the method is developed and evaluated for coolant property uncertainties, it is readily applicable for other parameters of interest.

9 April 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
RORyotaro Okabe
Ryotaro Okabe
SXShangjie Xue
Shangjie Xue
JVJayson R. Vavrek
Jayson R. Vavrek
JIANKAI YUJIANKAI YU
JIANKAI YU
RPRyan Pavlovsky
Ryan Pavlovsky
MLMingda Li
Mingda Li
Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

3 April 2010 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
KAKhalid Alammar
Khalid Alammar
LHLin-Wen Hu
Lin-Wen Hu