Wei Han

Wei Han

Auto-generated profile, based on publicly available information

Wei Han

State Grid Taiyuan Power Supply Company,Taiyuan,China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2020 in IEEE Access
Verified
Journal Article
Open access
MYMeng Yin
Meng Yin
HWHaoting Wu
Haoting Wu
ZXZhigang Xu
Zhigang Xu
WHWei Han
Wei Han
ZZZhiliang Zhao
Zhiliang Zhao
Tendon-sheath actuators (TSAs), similar to Bowden cable-based series elastic actuators (SEAs), have a wide range of applications in robots. However, when applying them to manipulators, force sensors cannot be mounted due to limited space. Therefore, this paper proposes a new method for compliant control based on a dual encoder, and the existing transmission model was improved by considering the joint torque. To validate the proposed method, experimental setups composed of a motor, a tendon-sheath component, a robotic joint, force sensors, and position sensors are established. The transmission processes are interpreted clearly through a position control mode. Parameter identifications without external disturbance force are conducted to acquire the ideal transmission model, and the error value between the experiment data and the fitted curve is measured. The availability of the presented scheme is verified by compliant control experiments, including collision detection and hand guiding, and the frequency characteristics of the actuator are analyzed. The results show that the function can be realized without force and torque sensors during the whole process.

8 December 2021
Verified
Conference Paper
Closed access
YTYuhang Tang
Yuhang Tang
YNYanru Ni
Yanru Ni
KYKun Yu
Kun Yu
XZXiangjun Zeng
Xiangjun Zeng
CZChao Zhuo
Chao Zhuo
WHWei Han
Wei Han
The stray current of urban rail transit will lead to nearby soil potential change, which will cause transformer DC bias. Therefore, the calculation model of earth potential distribution was established based on complex soil structure in this paper Firstly, the traction power supply model of urban rail transit was established, and the analytical expression of stray current distribution was derived. Then, based on the numerical distribution results of metro stray current, the complex soil structure was established by finite element simulation software, and the soil potential calculation was realized. The simulation results showed that the soil structure has absolute influence on the change of earth potential distribution caused by metro stray current. With the greater the difference in soil resistivity of different layers, the influence on the soil potential is more obvious. The calculation of soil potential distribution caused by metro stray current can be realized, which has certain guiding significance for the evaluation of transformer DC bias.