Xirong Liang

Xirong Liang

Auto-generated profile, based on publicly available information

Xirong Liang

State Key Laboratory of Isotope Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2001 in Science in China Series D: Earth Sciences
Verified
Journal Article
Closed access
PDF file
XLXirong Liang
Xirong Liang
GWGangjian Wei
Gangjian Wei
LSLei Shao
Lei Shao
XLXianhua Li
Xianhua Li
RWRucheng Wang
Rucheng Wang

2 June 2011 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
GWGuiqin Wang
Guiqin Wang
YLYangting Lin
Yangting Lin
XLXirong Liang
Xirong Liang
YLYing Liu
Ying Liu
LXLiewen Xie
Liewen Xie
XTXianglin Tu
Xianglin Tu
We report a modified procedure for separating Mg and Al from meteorites and terrestrial igneous rocks for high-precision analysis of Mg isotopes with multiple collector-inductively coupled plasma-mass spectrometry. The separating procedure was carried out in a single ion-exchange column filled with AG50W-X12 resin, and Mg was eluted with 1 M HNO3 , followed by Al eluted with 4M HNO3 . The modified procedure efficiently eliminates most matrix elements (except for Ni, Co, and Cu) with a recovery yield of Mg > 99%. Measurements of Ni-, Co-, and Cu-bearing simulation solutions revealed no detectable matrix effects. However, test runs demonstrated significant mass-dependent fractionation during the chromatographic process; consequently, a high recovery yield of Mg (>99%) is required to limit the deviation to less than 0.05‰. Furthermore, analysis of Mg standard solution with a wide range of concentrations demonstrated negligible deviation for samples with concentrations of 0.3–2.5 μg ml−1Mg relative to Mg standard solution concentrations of 1 μg ml−1Mg. The total procedure bank is less than 2 ng. The long-term reproducibility of instrumental measurements of Mg isotopes is ±0.05‰ for δ25Mg, ±0.10‰ for δ26Mg, and ±0.06‰ for δ26Mg* (2 SD, n = 211), based on analyzing five pure Mg standard solutions. Analysis of three chondrites and seven igneous rock standards showed ranges of δ26Mg(DSM3) from 0.02‰ to 0.30‰ for the former and from 0.03‰ to 0.30‰ for the latter. This method is simple and actionable.

1 July 1999 in Chemistry Letters
Verified
Journal Article
Closed access
XLXirong Liang
Xirong Liang
XLXian-Hua Li
Xian-Hua Li
MSMin Sun
Min Sun
YLYing Liu
Ying Liu
XTXianglin Tu
Xianglin Tu