Arian Azizi

Arian Azizi

Auto-generated profile, based on publicly available information

Arian Azizi

Zero Emission Realization of Optimized Energy Systems (ZEROES) Laboratory Department of Electrical and Computer Engineering The University of Texas at Dallas Richardson Texas USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2023 in Energy
Verified
Journal Article
Closed access
ATAshkan Toopshekan
Ashkan Toopshekan
AAAli Abedian
Ali Abedian
AAArian Azizi
Arian Azizi
Esmaeil AhmadiEsmaeil Ahmadi
Esmaeil Ahmadi
MRMohammad Amin Vaziri Rad
Mohammad Amin Vaziri Rad

28 May 2024 in High Voltage
Verified
Journal Article
Open access
AAArian Azizi
Arian Azizi
Mona GhassemiMona Ghassemi
Mona Ghassemi
The next generation of aircraft, including more electric aircraft and all‐electric aircraft (AEA), requires electric power systems with high power density and low system mass specifications. Increasing the voltage of the system to the range of a few kV, medium voltage (MV), is a reasonable approach to achieving high‐power‐density and low‐system‐mass EPSs for aircraft applications. Higher voltages, however, pose many challenges for aviation MV power cables such as arcs and arc tracking, partial discharges (PDs), and thermal management. In this regard, thermal management is more challenging since heat transfer by convection is greatly reduced at wide‐body aircraft's cruising altitudes due to the reduced air pressure. In this paper, a finite element method (FEM) model is developed in COMSOL Multiphysics for an aircraft bipolar MVDC (±5 kV) power cable. Using the model, the maximum permissible cable current at a low pressure of 18.8 kPa (at an altitude of 12.2 km from sea level, the usual cruising altitude for wide‐body aircraft) is calculated. Also, an analytical model is developed based on analytical and proven empirical correlations governing conductive, radiative, and convective heat transfers at the steady state to estimate the ampacity of the bipolar cable system at reduced pressure. It was shown that the proposed analytical model can be used for atmospheric pressure and systems with a larger number of poles, expanding its range of applications. The results of the FEM and analytical models correlate at wide ranges of parameters such as ambient temperature, duct size, distance between the positive and negative pole cables, and the overall diameter of the cables. The influence of horizontal and vertical arrangement of poles is included in the analytical model. The results of this study can be used to design bipolar MVDC power cable systems for the envisaged wide‐body AEA.